Spectroscopic Determination of C2 Densities in AR/H 2/CH 4 and AR/H2/C60 Microwave Plasmas For Nanocrystalline Diamond Synthesis

1997 ◽  
Vol 502 ◽  
Author(s):  
A. N. Goyette ◽  
J. E. Lawler ◽  
L. W. Anderson ◽  
D. M. Gruen ◽  
T. G. Mccauley ◽  
...  

ABSTRACTWe have measured the steady state concentration of gas phase C2 in Ar/H2/CH4 and Ar/H2/C60 microwave plasmas used for the deposition of nanocrystalline diamond films. High sensitivity white light absorption spectroscopy is used to monitor the C2 density using the d 3 Π ← a3Π (0,0) vibrational band of C2 as chamber pressure, microwave power, substrate temperature and feed gas mixtures are varied in both chemistries. Understanding how these parameters influence the C2 density in the plasma volume provides insight into discharge mechanisms relevant to the deposition of nanocrystalline diamond.

2020 ◽  
Vol 831 ◽  
pp. 127-131
Author(s):  
S.Tipawan Khlayboonme ◽  
Thowladda Warawoot

Ultra-nanocrystalline diamond films were prepared by a microwave plasma-enhanced chemical vapor deposition reactor using CH4/H2 gas mixture with a power as low as 650 W. The effects of CH4 concentration on nanostructure of the films and gas-phase species in plasma were investigated. The CH4 concentrations of 1.5%, 3.0%, 3.5%, and 4.0% were used and balanced with H2 to a total flow rate of 200 sccm. Morphology and composition of the films were characterized by SEM, Raman spectroscopy and Auger spectroscopy. The gas-phase species and electron density in the plasma were explored by optical emission spectroscopy and plasma-impedance measurement. The increasing CH4 concentration from 1.5% to 4.0% increased C2Hx species and decreased electron density. Phase of the film transform from nano- into ultranano- diamond phase but the growth rate revealingly decreased from 300 to 210 nm/h. Raman spectra indicate the higher CH4 concentration promted phase of the film transiton from NCD to UNCD. While Auger spectra revealed that UNCD film deposited with 4.0%CH4 was composed of 90.52% diamond phase but only 9.48% of graphite phase. The relation between phase transformation of the films and growth mechnism controlled by gas-phase species in the plasma will be dissused.


Author(s):  
Cyril Popov ◽  
Miroslav Jelínek ◽  
S. Boycheva ◽  
V. Vorlícek ◽  
Wilhelm Kulisch

Nanocrystalline diamond (NCD) films have been prepared by microwave plasma chemical vapor deposition (MWCVD) from methane/nitrogen mixtures, and the influence of the gas phase composition on the basic properties of the films (composition, morphology, topography, crystallinity and bonding structure) was investigated.


2019 ◽  
Vol 85 (2) ◽  
pp. 12-16
Author(s):  
I. V. Saunina ◽  
E. N. Gribanov ◽  
E. R. Oskotskaya

The sorption of Hg (II), Cd (II), and As (III) by natural aluminosilicate is studied. It is shown that the mineral absorbs those toxicants in a rather wide pH range, quantitative extraction of analytes being achieved in a neutral or close to neutral medium (pH values range within 7.0 - 8.0; 6.3 - 7.5; 7.4 - 8.5 for Hg (II), As (III), and Cd (II), respectively). The effect of the time of phase contact on the degree of extraction of elements is shown. The sorption capacity of the mineral in optimal conditions of the medium acidity (0.06 mmol/g for mercury, 0.31 mmol/g for cadmium, and 0.52 mmol/g for arsenic) is determined. The distribution coefficients attain values of aboutnX 103-nX 104. A new combined method for determination of Hg (II), Cd (II), and As (III) in natural and waste water is developed and tested. The method consists in a preliminary group sorption concentration of the analytes by aluminosilicate, desorption of the analytes from the surface of the mineral and their subsequent atomic absorption determination. The correctness of the method is verified in analysis of spiked samples. The method is easy to use and exhibits high sensitivity, reproducibility and accuracy of analyte determination. The relative standard deviation does not exceed 0.13. Economic availability and possibility of using domestic sorption materials are the important advantages of the proposed procedure which can be used in the practice of laboratories monitoring the quality and safety of environmental objects.


2020 ◽  
Vol 23 (10) ◽  
pp. 1010-1022
Author(s):  
Emrah Dural

Aim and scope: Due to the serious toxicological risks and their widespread use, quantitative determination of phthalates in cosmetic products have importance for public health. The aim of this study was to develop a validated simple, rapid and reliable high-performance liquid chromatography (HPLC) method for the determination of phthalates which are; dimethyl phthalate (DMP), diethyl phthalate (DEP), benzyl butyl phthalate (BBP), di-n-butyl phthalate (DBP), di(2- ethylhexyl) phthalate (DEHP), in cosmetic products and to investigate these phthalate (PHT) levels in 48 cosmetic products marketing in Sivas, Turkey. Materials and Methods: Separation was achieved by a reverse-phase ACE-5 C18 column (4.6 x 250 mm, 5.0 μm). As the mobile phase, 5 mM KH2PO4 and acetonitrile were used gradiently at 1.5 ml min-1. All PHT esters were detected at 230 nm and the run time was taking 21 minutes. Results: This method showed the high sensitivity value the limit of quantification (LOQ) values for which are below 0.64 μg mL-1 of all phthalates. Method linearity was ≥0.999 (r2). Accuracy and precision values of all phthalates were calculated between (-6.5) and 6.6 (RE%) and ≤6.2 (RSD%), respectively. Average recovery was between 94.8% and 99.6%. Forty-eight samples used for both babies and adults were successfully analyzed by the developed method. Results have shown that, DMP (340.7 μg mL-1 ±323.7), DEP (1852.1 μg mL-1 ± 2192.0), and DBP (691.3 μg mL-1 ± 1378.5) were used highly in nail polish, fragrance and cream products, respectively. Conclusion: Phthalate esters, which are mostly detected in the content of fragrance, cream and nail polish products and our research in general, are DEP (1852.1 μg mL-1 ± 2192.0), DBP (691.3 μg mL-1 ± 1378.5) and DMP (340.7 μg mL-1 ±323.7), respectively. Phthalates were found in the content of all 48 cosmetic products examined, and the most detected phthalates in general average were DEP (581.7 μg mL-1 + 1405.2) with a rate of 79.2%. The unexpectedly high phthalate content in the examined cosmetic products revealed a great risk of these products on human health. The developed method is a simple, sensitive, reliable and economical alternative for the determination of phthalates in the content of cosmetic products, it can be used to identify phthalate esters in different products after some modifications.


Molecules ◽  
2021 ◽  
Vol 26 (6) ◽  
pp. 1768
Author(s):  
Miroslav Rievaj ◽  
Eva Culková ◽  
Damiána Šandorová ◽  
Zuzana Lukáčová-Chomisteková ◽  
Renata Bellová ◽  
...  

This short review deals with the properties and significance of the determination of selenium, which is in trace amounts an essential element for animals and humans, but toxic at high concentrations. It may cause oxidative stress in cells, which leads to the chronic disease called selenosis. Several analytical techniques have been developed for its detection, but electroanalytical methods are advantageous due to simple sample preparation, speed of analysis and high sensitivity of measurements, especially in the case of stripping voltammetry very low detection limits even in picomoles per liter can be reached. A variety of working electrodes based on mercury, carbon, silver, platinum and gold materials were applied to the analysis of selenium in various samples. Only selenium in oxidation state + IV is electroactive therefore the most of voltammetric determinations are devoted to it. However, it is possible to detect also other forms of selenium by indirect electrochemistry approach.


Author(s):  
Isabel Abad-Álvaro ◽  
Diego Leite ◽  
Dorota Bartczak ◽  
Susana Cuello ◽  
Beatriz Gomez-Gomez ◽  
...  

Toxicological studies concerning nanomaterials in complex biological matrices usually require a carefully designed workflow that involves handling, transportation and preparation of a large number of samples without affecting the nanoparticle...


Sign in / Sign up

Export Citation Format

Share Document