A Computer Program to Facilitate Performance Assessment of Underground Low-Level Waste Concrete Vaults

1995 ◽  
Vol 412 ◽  
Author(s):  
K. A. Snyder ◽  
J. R. Clifton ◽  
J. Pommersheim

AbstractA computer program (4SIGHT) to facilitate performance assessment of underground concrete vaults for low level waste (LLW) disposal facilities is being developed at the National Institute of Standards and Technology (NIST). Specifically, the program predicts the hydraulic conductivity and the service life of an underground concrete vault. The hydraulic conductivity estimate is based upon empirical relations. The service life is estimated from consideration of three major degradation processes: steel reinforcement corrosion, sulfate attack, and leaching. The performance prediction is based upon ion transport equations for both diffusion and advection. Most importantly, the computer program incorporates the synergistic degradation effects of all three processes, and their effect upon the transport coefficients.

2013 ◽  
Vol 837 ◽  
pp. 265-270 ◽  
Author(s):  
Vasile Constantinescu ◽  
Gheorghe Veniamin Bogus ◽  
Rares George Taran ◽  
Ioan Carcea

Concrete is a complex material of construction that enables the high compressive strength of natural stone to be sed in any configuration. In tension, however, concrete can be no stronger than the bond between the cured cement and the surfaces of the aggregate. This is generally much lower than the compressive strength of the concrete. Concrete is therefore frequently reinforced, usually with steel. When a system of steel bars or a steel mesh is incorporated in the concrete structure in such a way that the steel can support most of the tensile stresses and leave the immediately surrounding concrete comparatively free of tensile stress, then the complex is known as reinforced concrete. Corrosion of reinforcing steel in concrete leads to the premature failure of many structures exposed to harsh environments. Rust products form on the bar, expanding its volume and creating stress in the surrounding concrete. This leads to cracking and spalling, both of which can severely reduce the service life and strength of a member. Corrosion of reinforcing steel in concrete structures is one of the most expensive problems facing civil engineers in the world. The structural integrity of many bridges, overpasses, parking garages, and other concrete structures has been impaired by corrosion, and repairs are urgently required to ensure public safety. Corrosion-induced deterioration of reinforced concrete can be modelled in terms of three component steps: (1) time for corrosion initiation; (2) time, subsequent to corrosion initiation, for appearance of a crack on the external concrete surface (crack propagation); and (3) time for surface cracks to progress into further damage and develop into spalls, to the point where the functional service life, is reached. The two most common causes of reinforcement corrosion are: (i) localized breakdown of the passive film on the steel by chloride ions and (ii) general breakdown of passivity by neutralization of the concrete, predominantly by reaction with atmospheric carbon dioxide. Sound concrete is an ideal environment for steel but the increased use of deicing salts and the increased concentration of carbon dioxide in modern environments principally due to industrial pollution, has resulted in corrosion of the rebar becoming the primary cause of failure of this material. The scale of this problem has reached alarming proportions in various parts of the world. Corrosion in reinforced concrete structures is causing deterioration of our infrastructure. Structures in or near marine environments and transportation structures on which deicing salts are used are especially vulnerable. A widely promoted method for repairing damaged structures or for protecting structures in corrosive environments is the application of fiber-reinforced composite wraps over the surface of the structures elements.


2013 ◽  
Vol 671-674 ◽  
pp. 1672-1675
Author(s):  
Yan Hui Li ◽  
Yang Yang Zhang ◽  
Jing Cun Wei ◽  
Yun Feng Wu

Through calculation and analysis on routine examination and neutralization of reinforced concrete chimney, the service life of concrete structure was evaluated only considering neutralization of concrete single factor. The results show that the neutralization of the reinforced concrete chimney was serious than that of other similar projects. The initiation time of reinforcement corrosion were 19.3a, cracking time of concrete cover were 27.35a.


1969 ◽  
Vol 3 (2) ◽  
pp. 269-280 ◽  
Author(s):  
L. B. Kapp ◽  
P. H. Richards

The problem is to determine the electrical and thermal conductivities of high pressure are plasmas from measurements of the current—voltage characteristics of the are and a single radial temperature profile. A new numerical method is described together with the corresponding computer program. The latter is applied to some recent measurements on wall-stabilized nitrogen ares, covering the temperature range 4500—11,000 °K, for which radiation can be neglected, and the results are compared with those of other workers.


2008 ◽  
Vol 399 ◽  
pp. 153-160 ◽  
Author(s):  
Katrien Audenaert ◽  
Liviu Marsavina ◽  
Geert de Schutter

Chloride initiated reinforcement corrosion is the main durability problem for concrete structures in a marine environment. If the chlorides reach the reinforcement steel, it will depassivate and start to corrode in presence of air and water. Since the corrosion products have a larger volume than the initial products, concrete stresses are induced, leading to spalling and degradation of the concrete structures. If cracks, caused by early drying, thermal effects, shrinkage movements or overstress, are present in the concrete, the penetration of chlorides is much faster compared to uncracked concrete. In this way, the corrosion process is initiated earlier and the service life is decreasing drastically. In order to study the influence of existing cracks in concrete structures on the penetration of chlorides a test program was set up at the Magnel Laboratory for Concrete Research of Ghent University, Belgium in cooperation with the “Politehnica” University of Timisoara, Romania. The first part of the test program consists of concrete specimens with artificial cracks. The chloride penetration into the concrete was realised with a non-steady state migration test and modelled with the finite element method COSMOS/FFE Thermal software. Based on the experimental and numerical results, a crack influencing factor was determined. With this factor, the resulting service life of the cracked concrete construction is determined and compared with the original service life.


Sign in / Sign up

Export Citation Format

Share Document