scholarly journals Crack Stability in the Fracture of Cementitious Materials

1994 ◽  
Vol 370 ◽  
Author(s):  
S. Tandon ◽  
K.T. Faber ◽  
Z.P. Bazant

AbstractThe aim of the present study is to investigate the stability of crack propagation in cementitious materials. Tests were conducted on bend specimens in three-point and four-point loading conditions. Three-point bend specimens showed stable crack growth for mortar, normal strength and high strength concrete specimens. Alternatively, four-point bend specimens showed catastrophic failure for mortar and quasi-catastrophic failure for normal strength and high strength concrete specimens. Results will be discussed in relation to brittleness number model and specific microstructural features including the interfacial transition zone between the cement paste and the aggregate and the attendant toughening mechanisms.

2022 ◽  
Vol 1048 ◽  
pp. 359-365
Author(s):  
Ihtesham Hussain Mohammed ◽  
Ahmed Majid Salim Al Aamri ◽  
Shakila Javed ◽  
Yahya Ubaid Al Shamsi

In this study, an experimental investigation was done to study the behaviour of Normal Strength Concrete (NSC) and High Strength Concrete (HSC) Plain beams under torsion with the concrete mix of M40 and M100. No mineral admixtures are used to obtain the required strength of concrete. Eight NSC beams and eight HSC beams whose width was varying with 75 mm, 100 mm, and 150 mm; depth varying as 75 mm, 100 mm, 150 mm and 200 mm; and span of the beams varying 600 mm, 800 mm and 1200 mm were casted and cured to stud the effect of torsion. The principle aim of this study was to understand the torsional behaviour of the NSC and HSC beams for rotation, cracking, size effect and torsional strength. A standard torsional loading method was used for conducting the testing of beams. The results obtained were compared with different theories and code equations. It was observed that the torsional strength of the beam increases with the increase in strength of concrete. HSC beams have higher torsional strength than the NSC beams which has the same amount of reinforcement.


2002 ◽  
Vol 29 (2) ◽  
pp. 191-200 ◽  
Author(s):  
M Alavi-Fard ◽  
H Marzouk

Structures located in seismic zones require significant ductility. It is necessary to examine the bond slip characteristics of high strength concrete under cyclic loading. The cyclic bond of high strength concrete is investigated under different parameters, including load history, confining reinforcement, bar diameter, concrete strength, and the rate of pull out. The bond strength, cracking, and deformation are highly dependent on the bond slip behavior between the rebar and the concrete under cyclic loading. The results of cyclic testing indicate that an increase in cyclic displacement will lead to more severe bond damage. The slope of the bond stress – displacement curve can describe the influence of the rate of loading on the bond strength in a cyclic test. Specimens with steel confinement sustained a greater number of cycles than the specimens without steel confinement. It has been found that the maximum bond strength increases with an increase in concrete strength. Cyclic loading does not affect the bond strength of high strength concrete as long as the cyclic slip is less than the maximum slip for monotonic loading. The behavior of high strength concrete under a cyclic load is slightly different from that of normal strength concrete.Key words: bond, high strength, cyclic loading, bar spacing, loading rate, failure mechanism.


2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Iswarya Gowram ◽  
Beulah M ◽  
MR Sudhir ◽  
Mothi Krishna Mohan ◽  
Deekshith Jain

Urbanization and industrialization have dramatically increased the manufacture of cement causing substantial pollution of the environment. The primary global concern related to cement manufacture has been the management of the large carbon footprints. The usages of environmentally friendly cementitious materials in the construction of structures have proved to be a viable option to deal with this environmental concern. Therefore, it is necessary to further explore the usage of cementitious materials which can replace cement albeit partially. In this direction of research, two such cementitious materials, namely, natural zeolite and metakaolin have been investigated in this study. High-strength concrete M60 with natural zeolite and metakaolin as the partial replacements for the cement has been prepared in this work. Polycarboxylic ether-based superplasticizer solution has been used to enhance workability. The test specimen cast and cured for 3, 7, 28, 60, and 90 days at ambient room temperature has been tested for compressive strength, split tensile strength, and flexural strength as per the Indian standards. The optimum mix of high-strength concrete thus manufactured has met the Indian standards, and the combination of cement +5% natural zeolite +10% metakaolin has exhibited the highest compressive, split tensile, and flexural strengths at 90 days of curing. Natural zeolite and metakaolin when used in smaller proportions have increased the concrete strength, and these materials are recommended for partial replacement of cement.


2018 ◽  
Vol 21 (11) ◽  
pp. 1723-1732 ◽  
Author(s):  
Venkatesh KR Kodur

High-strength concrete is being increasingly used in a number of building applications, where structural fire safety is one of the primary design considerations. Many research studies clearly indicate that the fire performance of high-strength concrete is different from that of normal-strength concrete and that high-strength concrete may not exhibit same level of performance as normal-strength concrete under fire conditions. This article outlines key characteristics that influence the performance of high-strength concrete structural members under fire conditions. Data generated in previous experimental and numerical studies are utilized to illustrate various factors that influence fire performance of high-strength concrete structural members. Based on the published data, observations and trends on the behavior of high-strength concrete members, innovative strategies for mitigating spalling and enhancing fire resistance of high-strength concrete structural members are proposed.


2012 ◽  
Vol 598 ◽  
pp. 388-392
Author(s):  
Hong Qiang Chu ◽  
Lin Hua Jiang ◽  
Ning Xu ◽  
Chuan Sheng Xiong

The mechanical properties of C100 high-strength concrete used for frozen shaft were studied in this research. The results demonstrate that: The cementitious materials 570kg/m3 concrete 28 strength is only 104.5MPa, which is lower than the C100 requirements; the early strength (3d) of the concrete doped with 30% admixture is less than 20% admixture concrete, but with the age increase, its strength gradually reaches close to concrete doped with 20% admixture, and eventually exceeds the concrete doped with 20% admixture.The tension-compression of high strength concrete doped with 15% fly ash and 15% slag is the smallest, while the tension-compression of the concrete doped 10% fly ash and 10% slag reaches the maximum.The Poisson's ratio of C100 concrete is between 0.20 and 0.24; the compressive elastic modulus is about 50GPa; and the tensile elastic modulus is about 110GPa.


1990 ◽  
Vol 211 ◽  
Author(s):  
Mette Glavind ◽  
Tine Aarre

AbstractThe application of high-strength concrete in practice is strongly limited by its more brittle behaviour than normal strength concrete.The present study deals with an investigation of the possibilities of increasing the fracture toughness of high-strength concrete by adding fibres. Tests are made with both normal strength concrete and high-strength concrete containing different amounts of steel and polypropylene fibres. Stress-strain curves in compression are obtained by a deformation controlled test system. The toughness is described with different toughness indexes.By using a previously proposed expression for the stress-strain curves, it is possible to make a non-linear load carrying capacity calculation for reinforced concrete beams. The results of the load carrying capacity calculation are compared with results of similar calculations made with the Danish code extrapolated to be valid for high-strength concrete.The investigation shows that the addition of especially steel fibres is effective in increasing toughness and the non-linear load carrying capacity for high-strength concrete. It is also shown that the compression strength of high-strength concrete is increased by addition of steel fibres. The results of the load carrying capacity calculation show that the Danish code cannot be extrapolated to be valid for high-strength concrete without any modifications.


1998 ◽  
Vol 25 (6) ◽  
pp. 975-981 ◽  
Author(s):  
VKR Kodur

Results from an experimental program on the behaviour of high strength concrete-filled steel hollow structural section (HSS) columns will be presented for three types of concrete filling. A comparison will be made of the fire-resistance performance of HSS columns filled with normal strength concrete, high strength concrete, and steel-fibre-reinforced high strength concrete. The various factors that influence the structural behaviour of high strength concrete-filled HSS columns under fire conditions are discussed. It is demonstrated that, in many cases, addition of steel fibres into high strength concrete improves the fire resistance and offers an economical solution for fire-safe construction.Key words: high strength concrete, steel columns, fire-resistance design, high-temperature behaviour, concrete-filled steel columns.


Sign in / Sign up

Export Citation Format

Share Document