Interface Formation and Thin Film Properties of an Incompatible Polymer System

1992 ◽  
Vol 280 ◽  
Author(s):  
B. Guckenbiehl ◽  
M. Stamm ◽  
T. Springer

ABSTRACTThe polymer blend system of deuterated polystyrene (PSd) and the statistical copolymer poly(styrene-co-para-bromo-styrene) (PBrxS) is partially compatible or incompatible depending on the degree of bromination x. The width of the interface in a bilayer system can thus be controlled in a wide range by an adjustment of x. This is demonstrated in neutron reflectivity experiments where the interfacial width is measured with an accuracy better than lnm. The interface width depends strongly on compatibility as expressed by the Flory-Huggins interaction parameter x- Results are compared with current theories.

2005 ◽  
Vol 97 (10) ◽  
pp. 103525 ◽  
Author(s):  
Y. Z. Yoo ◽  
O. Chmaissem ◽  
S. Kolesnik ◽  
B. Dabrowski ◽  
M. Maxwell ◽  
...  

1984 ◽  
Vol 30 (8) ◽  
pp. 1310-1313 ◽  
Author(s):  
J S Weiss ◽  
M W Sundberg ◽  
G M Dappen ◽  
R W Spayd ◽  
T W Wu ◽  
...  

Abstract We compared results for total bilirubin as measured on a coated thin film and by the Evelyn-Malloy and Jendrassik-Gróf methods. We examined serum samples from patients and studied the effects of protein, hemoglobin, and lipids on bilirubin measurement. Results from the thin-film assay compared favorably with those of the other methods. Total and within-day precision (CV), assessed over a one-year period, were better than 6% and 3%, respectively, at all concentrations. Analytical recovery was 99 +/- 3%. Samples from individuals having a wide range of liver diseases demonstrated, by linear regression, good correlation between the thin-film method and the two wet-chemistry methods (correlation coefficients of 0.990 and 0.994). We conclude that the thin-film method offers a valid alternative assay for total bilirubin.


2000 ◽  
Vol 50 (1) ◽  
pp. 107-112 ◽  
Author(s):  
H Grüll ◽  
A Schreyer ◽  
N. F Berk ◽  
C. F Majkrzak ◽  
C. C Han

Author(s):  
Svitlana Lobchenko ◽  
Tetiana Husar ◽  
Viktor Lobchenko

The results of studies of the viability of spermatozoa with different incubation time at different concentrations and using different diluents are highlighted in the article. (Un) concentrated spermatozoa were diluented: 1) with their native plasma; 2) medium 199; 3) a mixture of equal volumes of plasma and medium 199. The experiment was designed to generate experimental samples with spermatozoa concentrations prepared according to the method, namely: 0.2; 0.1; 0.05; 0.025 billion / ml. The sperm was evaluated after 2, 4, 6 and 8 hours. The perspective of such a study is significant and makes it possible to research various aspects of the subject in a wide range. In this regard, a series of experiments were conducted in this area. The data obtained are statistically processed and allow us to highlight the results that relate to each stage of the study. In particular, in this article it was found out some regularities between the viability of sperm, the type of diluent and the rate of rarefaction, as evidenced by the data presented in the tables. As a result of sperm incubation, the viability of spermatozoa remains at least the highest trend when sperm are diluted to a concentration of 0.1 billion / ml, regardless of the type of diluent used. To maintain the viability of sperm using this concentration of medium 199 is not better than its native plasma, and its mixture with an equal volume of plasma through any length of time incubation of such sperm. Most often it is at this concentration of sperm that their viability is characterized by the lowest coefficient of variation, regardless of the type of diluent used, which may indicate the greatest stability of the result under these conditions. The viability of spermatozoa with a concentration of 0.1 billion / ml is statistically significantly reduced only after 6 or even 8 hours of incubation. If the sperm are incubated for only 2 hours, regardless of the type of diluent used, the sperm concentrations tested do not affect the viability of the sperm. Key words: boar, spermatozoa, sperm plasma, concentration, incubation, medium 199, activity, viability, rarefaction.


1996 ◽  
Vol 118 (3) ◽  
pp. 439-443 ◽  
Author(s):  
Chuen-Huei Liou ◽  
Hsiang Hsi Lin ◽  
F. B. Oswald ◽  
D. P. Townsend

This paper presents a computer simulation showing how the gear contact ratio affects the dynamic load on a spur gear transmission. The contact ratio can be affected by the tooth addendum, the pressure angle, the tooth size (diametral pitch), and the center distance. The analysis presented in this paper was performed by using the NASA gear dynamics code DANST. In the analysis, the contact ratio was varied over the range 1.20 to 2.40 by changing the length of the tooth addendum. In order to simplify the analysis, other parameters related to contact ratio were held constant. The contact ratio was found to have a significant influence on gear dynamics. Over a wide range of operating speeds, a contact ratio close to 2.0 minimized dynamic load. For low-contact-ratio gears (contact ratio less than two), increasing the contact ratio reduced gear dynamic load. For high-contact-ratio gears (contact ratio equal to or greater than 2.0), the selection of contact ratio should take into consideration the intended operating speeds. In general, high-contact-ratio gears minimized dynamic load better than low-contact-ratio gears.


Nanoscale ◽  
2021 ◽  
Author(s):  
Keonwon Beom ◽  
Jimin Han ◽  
Hyun-Mi Kim ◽  
Tae-Sik Yoon

Wide range synaptic weight modulation with a tunable drain current was demonstrated in thin-film transistors (TFTs) with a hafnium oxide (HfO2−x) gate insulator and an indium-zinc oxide (IZO) channel layer...


2021 ◽  
Author(s):  
Danila Piatov ◽  
Sven Helmer ◽  
Anton Dignös ◽  
Fabio Persia

AbstractWe develop a family of efficient plane-sweeping interval join algorithms for evaluating a wide range of interval predicates such as Allen’s relationships and parameterized relationships. Our technique is based on a framework, components of which can be flexibly combined in different manners to support the required interval relation. In temporal databases, our algorithms can exploit a well-known and flexible access method, the Timeline Index, thus expanding the set of operations it supports even further. Additionally, employing a compact data structure, the gapless hash map, we utilize the CPU cache efficiently. In an experimental evaluation, we show that our approach is several times faster and scales better than state-of-the-art techniques, while being much better suited for real-time event processing.


CORROSION ◽  
1976 ◽  
Vol 32 (10) ◽  
pp. 414-417 ◽  
Author(s):  
R. WALKER

Abstract The use of triazole, benzotriazole, and naphthotriazole as corrosion inhibitors for brass is briefly reviewed. The corrosion of 70/30 brass immersed in a wide range of solutions is reported both with and without the inhibitors. The inhibitor efficiency of benzotriazole is given as a function of the solution pH and the concentration used. Triazole was only effective in mildly corrosive solutions and benzotriazole and naphthotriazole were much better. Generally naphthotriazole was better than benzotriazole but is much more expensive and a higher concentration of benzotriazole can give the same protection as naphthotriazole at a much lower cost.


Sign in / Sign up

Export Citation Format

Share Document