Ion Implanted Ti-6Al-4V

1983 ◽  
Vol 27 ◽  
Author(s):  
W. C. Oliver ◽  
R. Hutchings ◽  
J. B. Pethica ◽  
E. L. Paradis ◽  
A. J. Shuskus

ABSTRACTTitanium and many of its alloys show very poor wear resistance considering their hardness. This together with high thermodynamic driving forces to form very hard compounds between titanium and nitrogen or carbon made titanium based alloys obvious candidates for ion implantation. In this paper the effects of similar implanted concentration profiles of nitrogen and carbon in two titanium alloys are compared. The wear behavior of pin on disk wear tests are reported along with the ultramicrohardness of the four samples.

2019 ◽  
Vol 26 (02) ◽  
pp. 1850143
Author(s):  
SAEED NIYAZBAKHSH ◽  
KAMRAN AMINI ◽  
FARHAD GHARAVI

Anodic oxide coatings are applied on aluminum alloys in order to improve corrosion resistance and to increase hardness and wear resistance. In the current study, a hard anodic coating was applied on AA7075-T6 aluminum alloy. To survey the anodizing temperature (electrolyte temperature) effect, three temperatures, namely, [Formula: see text]C, 0∘C and 5∘C were chosen and the samples were sealed in boiling water and sodium dichromate to study the role of sealing. For measuring the oxide coatings porosity and hardness and also for comparing the samples’ wear resistance field-emission scanning electron microscopy (FESEM), microhardness test and pin-on-disk method were utilized, respectively. The results showed that by increasing the anodizing temperature, hardness and consequently wear resistance decreased so that hardness and weight loss in the samples with no sealing decreased from 460[Formula: see text]HV and 0.61[Formula: see text]mg at [Formula: see text]C to 405 and 358[Formula: see text]HV and 1.05 and 1.12[Formula: see text]mg at 0∘C and 5∘C, respectively, which is due to the porosity increment by increasing the anodizing temperature. Also, sealing in boiling water and dichromate contributed to soft phases and coating hydration, which resulted in a decrease in hardness and wear resistance. Hardness and weight loss in the coated samples at [Formula: see text]C decreased from 460[Formula: see text]HV and 0.61[Formula: see text]mg in the samples with no sealing to 435 and 417[Formula: see text]HV and 0.72 and 0.83[Formula: see text]mg in the samples sealed in boiling water and dichromate, respectively.


1983 ◽  
Vol 27 ◽  
Author(s):  
R. Martinella ◽  
G. Chevallard ◽  
C. Tosello

ABSTRACTMechanically polished Ti6Al4V samples were implanted with 100 key nitrogen ions to a fluence of 5.1017 ions/cm2 at two different bulk tenneratures: 370°C and 470°C. Wear tests were carried out with a reciprocating slidina tribotester. Structural modifications and wear morphologies were studied by TEM and SEM. 370°C implanted sample showed the same wear behavior as unimplanted ones, while 470°C implanted sample showed better wear resistance because of a TiN hardened layer. Correlations- between microstructural modifications, wear behavior and mechanisms are reported: results agree with the delamination theory. Comparison with ion- and gas-nitrided samples are presented.


2007 ◽  
Vol 342-343 ◽  
pp. 557-560
Author(s):  
Kwon Yong Lee ◽  
Hwan Kim ◽  
D.W. Kim ◽  
Dae Joon Kim ◽  
Myung Hyun Lee ◽  
...  

The sliding wear of four different compositions of novel low temperature degradation-free zirconia/alumina (LTD-free Z/A) composites were characterized in a ceramicceramic point contact pair. The wear tests were performed by a pin-on-disk type wear tester in a linear reciprocal sliding motion with a point contact in both dry and bovine serum lubricated conditions at room temperature. For the dry sliding wear tests, AZ-2 (20 vol% (Y,Nb,Ce)-TZP/ 80 vol% Al2O3) showed the best wear resistance among four kinds of LTD-free Z/A composites. For the bovine serum lubricated sliding wear tests, wear was too little to be measured for all kinds of Z/A composites. These novel LTD-free Z/A composites having excellent wear resistance demonstrated a potential as the alternative materials for the ceramic- ceramic contact pairs of femoral head and acetabular liner in total hip replacement.


2019 ◽  
Vol 26 (07) ◽  
pp. 1850217 ◽  
Author(s):  
O. ÇOMAKLI ◽  
A. F. YETIM ◽  
B. KARACA ◽  
A. ÇELIK

The 31CrMoV9 steels were plasma nitrided under different gas mixture ratios to investigate an influence of nitrogen amount on wear behavior. The structure, mechanical and tribological behavior of untreated and nitrided 31CrMoV9 steels were analyzed with X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), microhardness device, 3D profilometer and pin-on-disk wear tester. The analysis outcomes displayed that the compound layer consists of nitride phases (Fe2N, Fe3N, Fe4N and CrN). Additionally, the thickness of the compound layers, surface hardness and roughness increased with increasing nitrogen amount in the gas mixture. The highest friction coefficient value was obtained at nitrogen amount of 50%, but the lowest value was seen at nitrogen amount of 6%. It was observed that wear resistance of 31CrMoV9 steel improved after plasma nitriding, and the best wear resistance was also obtained from plasma nitrided sample at the gas mixture of 94% H[Formula: see text]% N2.


2021 ◽  
Author(s):  
Safiye İpek Ayvaz ◽  
Mehmet Ayvaz

In this study, the effect of different counterparts on the wear resistance of AA6082 aluminum alloy was investigated. In tests using pin-on-disk method, 6 mm diameter Al2O3, 100Cr6 and WC-6Co balls were used as counterparts. The tests were carried out using 500 m sliding distance and 5N load. The lowest specific wear rate was measured as 7.58x10-4 mm3/Nm in WC-6Co / AA6082 couple, and the highest value was measured as 9.71x10-4 mm3/Nm in 100Cr6/AA6082 couple. In the Al2O3/AA6082 couple, the specific wear rate of the AA6082-T6 sample was determined as 8.23x10-4 mm3/Nm.While it was observed that the dominant wear type in the 100Cr6/AA6082 pair was abrasive wear, oxidation wear and oxide tribofilm were detected in the WC-6Co/AA6082 and Al2O3/AA6082 couple besides the abrasive wear.


2021 ◽  
Vol 1016 ◽  
pp. 56-62
Author(s):  
Carlos Camurri ◽  
Jasmín Maril ◽  
Eric Romero

The aim of this work was to study the wear behavior of high-chromium white cast iron of families ASTM A-532 II (B, D) and III A, used in mining equipment, in order to establish relationships between the wear resistance, hardness and microstructure of the alloys, with the ultimate purpose of predicting their resistance to abrasion. Samples from these cast irons were subjected to mechanical wear tests by rotating drum, then their micro/macro hardness was measured and microstructure analyzed by optical and scanning electron microscopy .It was found that when the macroscopic hardness differences were significant there was a strong correlation between the hardness and the loss of mass due to abrasion-impact wear. By contrast, when the alloys had similar hardness, the wear resistance was determined by morphology, size, and the distribution and connectivity of carbides and matrix and therefore was not predictable by an only simple hardness test.


2020 ◽  
Vol 143 (1) ◽  
Author(s):  
Tuba Yener ◽  
Azmi Erdogan ◽  
Mustafa Sabri Gök ◽  
Sakin Zeytin

Abstract The aim of this study was to investigate the effect of low-temperature aluminizing process on the microstructure and dry sliding wear properties of Mirrax steel. Low-temperature aluminizing process was applied on Mirrax steel at 600, 650, and 700 °C for 2, 4, and 6 h. The packs for the process were prepared using pure aluminum powder as aluminum deposition source. Ammonium chloride NH4Cl and Seydisehir Al2O3 powder were used as the activator and the inert filler, respectively. Scanning electron microscope (SEM)/energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD) analysis were applied for characterization of the coating surfaces. The through-thickness variation in the layer microstructure was determined and it was found to vary between 1 µm and 45 µm which increased with higher process temperature and time. After the deposition process, the coating layer hardness increased to 1000 HVN, whereas the hardness of the matrix was 250 HVN. The wear tests were performed using a ball-on-disc tribometer under 5 N load at room temperature and 500 °C on aluminized and untreated Mirrax steel. In both room temperature and high-temperature wear tests, it was determined that the aluminizing process increased the wear resistance of Mirrax steel. Increasing aluminizing time and temperature also increased the wear resistance. The uncoated and thin-coated samples generally exhibited wear in the form of plastic deformation and adhesion related ruptures. A high degree of tribological layer was observed on the wear trace on samples with high coating thickness, especially in high-temperature tests. Therefore, the volume losses in these samples were induced by fatigue crack formation and delamination.


2012 ◽  
Vol 562-564 ◽  
pp. 318-321 ◽  
Author(s):  
Xiao Peng Huang ◽  
Jing Feng Wu ◽  
Fang Xin Wan ◽  
Ke Ping Zhang

In this study, the wear behavior of 9SiCr steel under different treatment with plant abrasive was evaluated by using an abrasive rubber wheel tester. The samples’ microstructures were analyzed by a metallurgical microscope, the samples’ worn surface morphology was observed by using SEM.The results show that: With the increasing of hardness of sample, Its wear resistance is greatly improved. Hardness of laser quenching sample is the highest, wear resistance of it is the best, the second is sub temperature sample. The wear rates and the wear coefficients are proportional to the sliding distance. The Laser quenching samplel display a consistent behaviour with a very low wear rate and a small increase of the wear damage is observed during the abrasive wear tests. The worn surfaces of the three kind samples are characterized by the micro-cutting wear, and no treatment sample is accompanied by fatigue wear mechanism.


1983 ◽  
Vol 105 (2) ◽  
pp. 239-244 ◽  
Author(s):  
J. A. Kirk ◽  
G. W. Egerton ◽  
B. D. Sartwell

A pin on disk wear test apparatus was used to evaluate wear and friction properties for nitrogen ion implanted and non-ion implanted steel disks in the presence of a lubricant. Both AISI/1018 mild steel and 304 stainless steel were examined. Typical fluence levels for ion implantation were above 1017 ions/cm2. In this paper disk wear is measured directly by a Talysurf profilometer tracing of the disk wear scar. By varying the contact area of the pin it was possible to evaluate wear behavior of both unimplanted and implanted disks over a wide range of contact pressures. It is shown that stainless steel disk wear can be decreased by nitrogen ion implantation, provided that contact pressures remain less than the yield strength of the substrate material. No significant wear improvements were observed for 1018 steel. To evaluate improvements in hardness due to nitrogen ion implantation, very low penetration depth microhardness measurements were made and the indentation diagonals were measured in a scanning electron microscope. These results and their limitations are also presented.


Sign in / Sign up

Export Citation Format

Share Document