Rotational Diffusion of Chromophores Inside a Glassy Polymeric Film Studied By Electrooptical Interferometry

1989 ◽  
Vol 173 ◽  
Author(s):  
R. Meyrueix ◽  
G. Mignani

ABSTRACTPerot Fabry interferometry under oblique incidence provides a powerful tool for the determination of the complex values of the independant components of the tensors χ2(−ω;ω,ο) and χ3(−ω;ω,ο,ο) of poled films. Deorientation of Disperse Red One chromophore in a poled film can be followed by the decrease with time of two order parameters. In the short term regime, the relaxation times of this process are spread over a broad spectrum. By comparing the chromophore dynamics in PMMA, PS and SAN at different temperatures, it appears that free volume and secondary transition concepts cannot fully explain the chromophore behavior. Chromophore dipole/Polymer dipole interactions are invoked in order to explain the slow deorientation rate in SAN.

1985 ◽  
Vol 54 (02) ◽  
pp. 533-538 ◽  
Author(s):  
Wilfried Thiel ◽  
Ulrich Delvos ◽  
Gert Müller-Berghaus

SummaryA quantitative determination of soluble fibrin in plasma was carried out by affinity chromatography. For this purpose, desAA-fibrin and fibrinogen immobilized on Sepharose 4B were used at the stationary side whereas batroxobin-induced 125I-desAA-fibrin or thrombin-induced 125I-desAABB-fibrin mixed with plasma containing 131I-fibrinogen represented the fluid phase. The binding characteristics of these mixtures to the immobilized proteins were compared at 20° C and 37° C. Complete binding of both types of fibrin to the immobilized desAA-fibrin was always seen at 20° C as well as at 37° C. However, binding of soluble fibrin was accompanied by substantial binding of fibrinogen that was more pronounced at 20° C. Striking differences depending on the temperature at which the affinity chromatography was carried out, were documented for the fibrinogen-fibrin interaction. At 20° C more than 90% of the applied desAA-fibrin was bound to the immobilized fibrinogen whereas at 37° C only a mean of 17% were retained at the fibrinogen-Sepharose column. An opposite finding with regard to the tested temperature was made with the desAABB-fibrin. Nearly complete binding to insolubilized fibrinogen was found at 37° C (95%) but only 58% of the desAABB-fibrin were bound at 20° C. The binding patterns did not change when the experiments were performed in the presence of calcium ions. The opposite behaviour of the two types of soluble fibrin to immobilized fibrinogen at the different temperatures, together with the substantial binding of fibrinogen in the presence of soluble fibrin to insolubilized fibrin in every setting tested, devaluates affinity chromatography as a tool in the quantitative assessment of soluble fibrin in patients’ plasma.


Author(s):  
O. Yu. Atkov ◽  
S. G. Gorokhova

The individual dynamics of the allostatic load index was revealed mainly due to changes in the glucose level, body mass index, which makes it applicable for assessing the short-term adaptation to the stay in the conditions of shift work


2021 ◽  
Vol 75 (2-3) ◽  
pp. 119-131
Author(s):  
Albert A. Smith ◽  
Nicolas Bolik-Coulon ◽  
Matthias Ernst ◽  
Beat H. Meier ◽  
Fabien Ferrage

AbstractThe dynamics of molecules in solution is usually quantified by the determination of timescale-specific amplitudes of motions. High-resolution nuclear magnetic resonance (NMR) relaxometry experiments—where the sample is transferred to low fields for longitudinal (T1) relaxation, and back to high field for detection with residue-specific resolution—seeks to increase the ability to distinguish the contributions from motion on timescales slower than a few nanoseconds. However, tumbling of a molecule in solution masks some of these motions. Therefore, we investigate to what extent relaxometry improves timescale resolution, using the “detector” analysis of dynamics. Here, we demonstrate improvements in the characterization of internal dynamics of methyl-bearing side chains by carbon-13 relaxometry in the small protein ubiquitin. We show that relaxometry data leads to better information about nanosecond motions as compared to high-field relaxation data only. Our calculations show that gains from relaxometry are greater with increasing correlation time of rotational diffusion.


Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3013
Author(s):  
Leszek Czechowski

The paper deals with an examination of the behaviour of glued Ti-Al column under compression at elevated temperature. The tests of compressed columns with initial load were performed at different temperatures to obtain their characteristics and the load-carrying capacity. The deformations of columns during tests were registered by employing non-contact Digital Image Correlation Aramis® System. The numerical computations based on finite element method by using two different discrete models were carried out to validate the empirical results. To solve the problems, true stress-logarithmic strain curves of one-directional tensile tests dependent on temperature both for considered metals and glue were implemented to software. Numerical estimations based on Green–Lagrange equations for large deflections and strains were conducted. The paper reveals the influence of temperature on the behaviour of compressed C-profile Ti-Al columns. It was verified how the load-carrying capacity of glued bi-metal column decreases with an increase in the temperature increment. The achieved maximum loads at temperature 200 °C dropped by 2.5 times related to maximum loads at ambient temperature.


Sign in / Sign up

Export Citation Format

Share Document