scholarly journals Energy Optimisation in Office Buildings Through Daylighting Design for Climatic Conditions of Central India

2016 ◽  
Vol 3 (2) ◽  
pp. 133-147
Author(s):  
Komal Thakur ◽  
K.P. Rewatkar

This paper is based on the premise that energy optimisation is possible in office buildings through design of daylighting. The motivation for the study was born of the fact that in India, among all building typologies, commercial buildings consume the maximum energy. This energy consumption is mainly for cooling of the building and lighting the interior spaces. Cooling and lighting up spaces generates heat in and around the building, which again increases the cooling load. Out of the total electrical energy required in the building, around 20-40% is used for lighting purposes. Despite availability of daylight during the working hours, artificial lighting is used in offices that have huge internal spaces with large spans. This paper aims at understanding the factors related to daylight penetration into office building in different situations and developing guidelines for achieving maximum daylight penetration in large spaces.

2018 ◽  
Vol 16 (1) ◽  
pp. 24-31
Author(s):  
Wasiska Iyati ◽  
◽  
Eryani Nurma Yulita ◽  
Jusuf Thojib ◽  
Heru Sufianto ◽  
...  

The narrow land in big cities such as Jakarta, increases the amount of high rise building, especially multi-storey office building. Office building consumes much energy to provide air conditioning to meet the thermal comfort inside the building. On the other hand, the building shape, building envelope, and building orientation to the sun's position are the main factors in building design aspects that affect the amount of cooling load. This study aims to investigate the impact of the aspect ratio or the ratio of the longer dimension of an oblong plan to the shorter, on external heat gain of multi-storey office building. Variables examined include the transparent and solid area of building envelope, the total area of the surface of the building envelope in any orientation, and the volume of the building, as well as the influence of those proportion on the external heat gain. This study uses mathematical calculations to predict the cooling load of the building, particularly external heat gain through the walls, roof and glass, as well as comparative analysis of models studied. The study also aims to generate the design criteria of building form and proportion of multi-storey office buildings envelope with lower external heat gain. In Jakarta climatic conditions, the result on rectangular building plan with aspect ratio of 1 to 4 shows that the external heat gain did not differ significantly, and the smallest heat gain is found on the aspect ratio of 1.8. Results also showed that the greater aspect ratio, the greater reduction of external heat gain obtained by changing the orientation of the longest side facing east-west into the north-south, about 2.79% up to 42.14% on the aspect ratio of 1.1 to 4. In addition, it is known that in same building volume, changing the number of floors from 10 to 50 can improve the external heat gain almost twice.


2018 ◽  
Vol 175 ◽  
pp. 03027 ◽  
Author(s):  
Chengliang Fan ◽  
Yundan Liao ◽  
Yunfei Ding

An attempt was made to develop an improved autoregressive with exogenous (ARX) model for office buildings cooling load prediction in five major climates of China. The cooling load prediction methods can be arranged into three categories: regression analysis, energy simulation, and artificial intelligence. Among them, the regression analysis methods using regression models are much simple and practical for real applications. However, traditional regression models are often helpless to manage multiparameter dynamic changes, making it not accurate as the other two categories. Many of the existing cooling load prediction studies use piecewise linearization to manage nonlinearity. To improve the prediction accuracy of regression analysis methods, higher order and interaction terms are included in improved ARX based on traditional ARX model. The improved ARX model consists of eight variables, with eleven coefficients accessed at a time. For applications and evaluations, an office building in major cities within each climatic zone was selected as a representation. These cities were Harbin, Beijing, Nanjing, Kunming and Guangzhou respectively. The coefficient of determination R2 is greater than 0.9 in five cities. The prediction results show that the improved ARX model can adapt to different climatic conditions, including those nonlinearity cases.


2021 ◽  
pp. 147715352098742
Author(s):  
FŞ Yilmaz

Office buildings are building typologies where efficient and optimal use of lighting energy is crucial while providing comfortable visual environments. The purpose of this study is to explore the impact of diverse architectural design alternatives on lighting energy requirements and lighting energy saving possibilities through a case study. In this study, a total of 3888 design alternatives are investigated in a comparative way in terms of daylighting system design alternatives, artificial lighting system design scenarios, artificial lighting system control types and shading system control options. Introducing the adaptation process of the EN 15193-1:2017 standard for Turkey’s specific climatic and geographical conditions and considering diverse lighting design scenarios, results of this parametric study aim to underline the significance of architectural design strategies in office buildings for the reduction of lighting energy requirements.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3852
Author(s):  
Daniel Plörer ◽  
Sascha Hammes ◽  
Martin Hauer ◽  
Vincent van Karsbergen ◽  
Rainer Pfluger

A significant proportion of the total energy consumption in office buildings is attributable to lighting. Enhancements in energy efficiency are currently achieved through strategies to reduce artificial lighting by intelligent daylight utilization. Control strategies in the field of daylighting and artificial lighting are mostly rule-based and focus either on comfort aspects or energy objectives. This paper aims to provide an overview of published scientific literature on enhanced control strategies, in which new control approaches are critically analysed regarding the fulfilment of energy efficiency targets and comfort criteria simultaneously. For this purpose, subject-specific review articles from the period between 2015 and 2020 and their research sources from as far back as 1978 are analysed. Results show clearly that building controls increasingly need to address multiple trades to achieve a maximum improvement in user comfort and energy efficiency. User acceptance can be highlighted as a decisive factor in achieving targeted system efficiencies, which are highly determined by the ability of active user interaction in the automatic control system. The future trend is moving towards decentralized control concepts including appropriate occupancy detection and space zoning. Simulation-based controls and learning systems are identified as appropriate methods that can play a decisive role in reducing building energy demand through integral control concepts.


Actuators ◽  
2020 ◽  
Vol 10 (1) ◽  
pp. 1
Author(s):  
Tri Cuong Do ◽  
Duc Giap Nguyen ◽  
Tri Dung Dang ◽  
Kyoung Kwan Ahn

In this paper, a novel design of an energy regeneration system was proposed for recovering as well as reusing potential energy in a boom cylinder. The proposed system included a hydraulic pump/motor and an electrical motor/generator. When the boom moved down, the energy regeneration components converted the hydraulic energy to electrical energy and stored in a battery. Then, the regenerated energy was reused at subsequent cycles. In addition, an energy management strategy has been designed based on discrete time-optimal control to guarantee position tracking performance and ensure component safety during the operation. To verify the effectiveness of the proposed system, a co-simulation (using MATLAB and AMESim) was carried out. Through the simulation results, the maximum energy regeneration efficiency could achieve up to 44%. Besides, the velocity and position of the boom cylinder achieved good performance with the proposed control strategy.


2011 ◽  
Vol 110-116 ◽  
pp. 72-76 ◽  
Author(s):  
Mohammadjavad Mahdavinejad ◽  
Soha Matoor ◽  
Neda Feyzmand ◽  
Amene Doroodgar

The Issue of daylight inclusion in the office buildings has got the significant importance in the recent years. Using this light, dependence on artificial lighting sources can be reduced which results in the energy efficiency. This study aims to determine the optimal Window Wall Ratios in the office buildings of Tehran to take the advantage of daylight abundance regarding the climatic features without making the designers involved with the complicated calculations. All the research analyses have been done based on the window models comparison through the computational simulations. After the primary analyses, the models were developed and put to the test again. The study shows that among from all the tested models, an optimal WWR range for the office buildings of Tehran can be proposed.


2016 ◽  
Vol 27 (1) ◽  
pp. 129-142
Author(s):  
Trupti J. Dabe ◽  
Alpana R. Dongre

Daylighting integrated with artificial lighting control is recognized as an important and useful strategy in energy-efficient building designs. The prediction of the internal daylight levels is a key stage in daylighting designs. For this research, the ‘type design’ residential quarters building as a case has been selected from Nagpur region in central India having a hot and dry climate. These ‘type design’ have the major issues related to the performance of daylight and thermal comfort due to lack of some rules related to sizes of fenestrations in the development control regulation. The aim of this research is to evaluate the most critical liveable area of a dwelling unit of ‘type design’ for daylight and thermal comfort. This research includes evaluation of the selected parameters by comparative analysis of useful daylight illuminance (UDI), daylight autonomy (DA), thermal comfort hours and carpet area to window ratio (CAWR) with the help of dynamic simulation by using ‘Daysim’, ‘radiance analysis tool’ and ‘temperature distribution tool’ of Ecotect 2011 software. The findings of this research arrive to derive the CAWR with respect to orientation (four cardinal directions) of the building without compromising the thermal comfort with respect to the temperature of a dwelling unit of ‘type design’.


Author(s):  
Muhammadiya Rifqi ◽  
Heni Fitriani ◽  
Puteri Kusuma Wardhani

Buildings contribute more than 40% of world energy consumption, so it is feared that it will cause energy problems in thefuture, especially in the construction sector. One solution to reducing this problem is by analyzing energy use at the initialdesign stage and utilizing solar energy as one of the solar power plants (PLTS) in office buildings. To analyze the use ofenergy in buildings, Building Information Modeling (BIM) was used. The purpose of this research is to analyze the annualenergy level of office buildings in Palembang using BIM software, namely Autodesk Revit. The number of solar panels aswell as the amount of energy were also identified using web-based software (HelioScope) resulting the economic feasibilityas indicated by the installation of solar panels as a component of PV mini-grid. The results showed that the use of BIMtechnology in analyzing building energy can provide a detailed description of the building model at the design stage. Revitanalysis indicates that the building consumed electrical energy per year for about 3,647,713 kWh with a roof area of 1,657m2. In addition, based on the HelioScope analysis, the use of renewable energy from the installation of PLTS was 152,900kWh/year. Meanwhile, for economic feasibility analysis, the installation of PLTS in office buildings can provide a positive NetPresent Value (NPV), indicating a feasible project.