scholarly journals Scanning Reference Electrode Techniques in Localized Corrosion

2009 ◽  
pp. 3-3-31 ◽  
Author(s):  
HS Isaacs ◽  
B Vyas
1993 ◽  
Vol 35 (1-4) ◽  
pp. 127-134 ◽  
Author(s):  
K.R. Trethewey ◽  
D.A. Sargeant ◽  
D.J. Marsh ◽  
A.A. Tamimi

Materials ◽  
2020 ◽  
Vol 13 (9) ◽  
pp. 2158
Author(s):  
Andrea Brenna ◽  
Silvia Beretta ◽  
Marco Ormellese

Cathodic protection (CP), in combination with an insulating coating, is a preventative system to control corrosion of buried carbon steel pipes. The corrosion protection of coating defects is achieved by means of a cathodic polarization below the protection potential, namely −0.85 V vs. CSE (CSE, copper-copper sulfate reference electrode) for carbon steel in aerated soil. The presence of alternating current (AC) interference, induced by high-voltage power lines (HVPL) or AC-electrified railways, may represent a corrosion threat for coated carbon steel structures, although the potential protection criterion is matched. Nowadays, the protection criteria in the presence of AC, as well as AC corrosion mechanisms in CP condition, are still controversial and discussed. This paper deals with a narrative literature review, which includes selected journal articles, conference proceedings and grey literature, on the assessment, acceptable criteria and corrosion mechanism of carbon steel structures in CP condition with AC interference. The study shows that the assessment of AC corrosion likelihood should be based on the measurement of AC and DC (direct current) related parameters, namely AC voltage, AC and DC densities and potential measurements. Threshold values of the mentioned parameters are discussed. Overprotection (EIR-free < −1.2 V vs. CSE) is the most dangerous condition in the presence of AC: the combination of strong alkalization close to the coating defect due to the high CP current density and the action of AC interference provokes localized corrosion of carbon steel.


2002 ◽  
Vol 18 (04) ◽  
pp. 350-354
Author(s):  
Shao Min-Hua ◽  
◽  
Fu Yan ◽  
Hu Rong-Gang ◽  
Lin Chang-Jian

Author(s):  
W. A. Chiou ◽  
N. Kohyama ◽  
B. Little ◽  
P. Wagner ◽  
M. Meshii

The corrosion of copper and copper alloys in a marine environment is of great concern because of their widespread use in heat exchangers and steam condensers in which natural seawater is the coolant. It has become increasingly evident that microorganisms play an important role in the corrosion of a number of metals and alloys under a variety of environments. For the past 15 years the use of SEM has proven to be useful in studying biofilms and spatial relationships between bacteria and localized corrosion of metals. Little information, however, has been obtained using TEM capitalizing on its higher spacial resolution and the transmission observation of interfaces. The research presented herein is the first step of this new approach in studying the corrosion with biological influence in pure copper.Commercially produced copper (Cu, 99%) foils of approximately 120 μm thick exposed to a copper-tolerant marine bacterium, Oceanospirillum, and an abiotic culture medium were subsampled (1 cm × 1 cm) for this study along with unexposed control samples.


TAPPI Journal ◽  
2010 ◽  
Vol 9 (7) ◽  
pp. 35-41
Author(s):  
OUTI A. HYÖKYVIRTA ◽  
TOM E. GUSTAFSSON

This investigation evaluated the applicability of a molybdenum sulfide reference electrode (MSRE) as an internal reference electrode for use in alkaline sulfide solutions over a range of pulp digester liquors at 170°C. The electrode remained stable during the exposure period of two weeks. The experimentally determined half cell potential of the MSRE is E = -0.91 VSHE. The surface of the MSRE was examined by scanning electron microscope (SEM) and electron spectroscopy for chemical analysis (ESCA) to verify the chemical composition of the thin surface film. Based on ESCA studies, the surface film contained molybdenum disulfide and sodium disulfide. During storage of the specimens, sulfide was partly oxidized to sodium sulfite in air. Next to the metallic molybdenum, a mixed molybdenum disulfide and molybdenum hydroxide layer was detected.


Alloy Digest ◽  
1995 ◽  
Vol 44 (4) ◽  

Abstract VLX 954 is an austenitic stainless steel with 6% (nominal) molybdenum. The alloy is particularly resistant to localized corrosion in sea water and chloride environments. This datasheet provides information on composition, physical properties, elasticity, and tensile properties. It also includes information on high temperature performance and corrosion resistance as well as forming, heat treating, machining, and joining. Filing Code: SS-589. Producer or source: DMV Stainless USA Inc.


Alloy Digest ◽  
1995 ◽  
Vol 44 (3) ◽  

Abstract ZERON 25 is an alloy developed to combat severe oil field duties where oil, gas, water are contaminated with high levels of chlorides and hydrogen sulfide. The alloy has good mechanical strength and resistance to localized corrosion. This datasheet provides information on composition, physical properties, hardness, elasticity, and tensile properties as well as fracture toughness. It also includes information on corrosion resistance as well as forming, heat treating, machining, and joining. Filing Code: SS-584. Producer or source: Weir Material Services Ltd.