Comparison of Current Interruption and Electrochemical Impedance Techniques in the Determination of Corrosion Rates of Steel in Concrete

Author(s):  
NS Berke ◽  
DF Shen ◽  
KM Sundberg
Metals ◽  
2020 ◽  
Vol 10 (6) ◽  
pp. 775 ◽  
Author(s):  
Sebastián Feliu

From a technological point of view, measurement of the corrosion rate of magnesium (Mg) and its alloys is critical for lifetime predictions of Mg-based structures and for comparative assessments of their corrosion protection ability. Whilst weight loss, hydrogen evolution, and polarization curves methods are frequently used for measuring the corrosion rate, the determination of values by electrochemical impedance spectroscopy (EIS) is relatively scarce and has only been realized recently. This technique seems to be the most suitable for monitoring corrosion rate values due to its “non-destructive” character, its reproducibility, and its reliable determination of small corrosion rates, much lower than those measured by other techniques. This review aims to picture the state-of-the-art technique of using EIS for measuring the corrosion rate of Mg. This paper starts by introducing some fundamental aspects of the most widely used methods for monitoring the corrosion rate of Mg/Mg alloy and continues by briefly explaining some of the fundamental concepts surrounding EIS, which are essential for the user to be able to understand how to interpret the EIS spectra. Lastly, these concepts are applied, and different approaches that have been proposed to obtain quantitative values of corrosion rate since the 1990s are discussed.


2020 ◽  
Vol 39 (1) ◽  
pp. 340-350
Author(s):  
Mingjing Wang ◽  
Song Zeng ◽  
Huihui Zhang ◽  
Ming Zhu ◽  
Chengxin Lei ◽  
...  

AbstractCorrosion behaviors of 316 stainless steel (316 ss) and Inconel 625 alloy in molten NaCl–KCl–ZnCl2 at 700°C and 900°C were investigated by immersion tests and electrochemical methods, including potentiodynamic polarization and electrochemical impedance spectroscopy. X-ray diffraction and scanning electron microscopy/energy dispersive spectroscopy were used to analyze the phases and microstructures of the corrosion products. Inconel 625 alloy and 316 ss exhibited high corrosion rates in molten chlorides, and the corrosion rates of these two alloys accelerated when the temperature increased from 700°C to 900°C. The results of the electrochemical tests showed that both alloys exhibited active corrosion in chloride molten salt, and the current density of 316 ss in chloride molten salt at 700°C was 2.756 mA/cm−2, which is about three times the value for Inconel 625 alloy; and the values of the charge transfer resistance (Rt) for Inconel 625 were larger than those for 316 ss. The corrosion of these two alloys is owing to the preferred oxidation of Cr in chloride molten salt, and the corrosion layer was mainly ZnCr2O4 which was loose and porous and showed poor adherence to metal.


2019 ◽  
Vol 97 (2) ◽  
pp. 140-146
Author(s):  
Tian Gan ◽  
Zhikai Wang ◽  
Mengru Chen ◽  
Wanqiu Fu ◽  
Haibo Wang ◽  
...  

In this work, the Ag@Cu particles with yolk–shell nanostructure was prepared by facile solvothermal method, which was modified on glassy carbon electrode (GCE) to fabricate electrochemical sensor for the convenient and fast determination of p-aminobenzoic acid (PABA). The surface morphology and electrochemical properties of the as-prepared Ag@Cu nanocomposite modified electrode were characterized by scanning electron microscopy, transmission electron microscopy, chronocoulometry, and electrochemical impedance spectroscopy. Further, the electrochemical sensing of PABA was performed on the Ag@Cu/GCE using cyclic voltammetry and differential pulse voltammetry techniques, showing high catalytic activity. Under the optimal conditions, the sensor exhibited a wide linear range, high sensitivity, and low detection limit of 0.315 μmol/L for PABA. The developed sensor was also successfully applied for PABA detection in anesthetic and cosmetics with satisfactory results.


Measurement ◽  
2016 ◽  
Vol 92 ◽  
pp. 524-533 ◽  
Author(s):  
Achour Terbouche ◽  
Siham Lameche ◽  
Chafia Ait-Ramdane-Terbouche ◽  
Djamila Guerniche ◽  
Djahida Lerari ◽  
...  

2009 ◽  
Vol 97 (4-5) ◽  
Author(s):  
K. M. Dziewinska ◽  
A. M. Peters ◽  
J. A. La Verne ◽  
P. Martinez ◽  
J. J Dziewinski ◽  
...  

AbstractDensity measurements of plutonium metal and its alloys are performed at Los Alamos National Laboratory (LANL) using a technique based on the Archimedes principle. The goal is to find and characterize a fluid for density determination of large objects made of plutonium to replace the currently used monobromobenzene. Physical and chemical properties must be considered while selecting the fluid. Chemical properties of the fluid must ensure low corrosion rates and good resistance to radiological decomposition. The study was carried on to evaluate the corrosion rates of Pu metal cause by FC-43 and the FC-43 decomposition products of radiolysis. The results of these studies proved favourable for this application. The evaluation of the surface reactions between FC-43 and Pu metal will be conducted in the near future.


2019 ◽  
Vol 63 (1) ◽  
Author(s):  
Mehdi Jalali ◽  
Zeinab Deris Falahieh ◽  
Mohammad Alimoradi ◽  
Jalal Albadi ◽  
Ali Niazi

The electrochemical behavior of Bi+3 ions on the surface of a glassy carbon electrode, in acidic media and in the presence of tamoxifen, was investigated. Cyclic voltammetry, chronoamperometry, differential pulse voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy with energy-dispersive X-ray spectroscopy were used to find the probable mechanism contributing to the reduction of the peak height of bismuth oxidation with an increase in the concentration of tamoxifen. The obtained results show a slight interaction between the bismuth species and tamoxifen which co-deposit on the surface of glassy carbon electrode. Therefore, the reduction in the peak height of bismuth oxidation as a function of tamoxifen concentration was used to develop a new differential pulse anodic striping voltammetry method for determination of trace amount of tamoxifen. The effects of experimental parameters on the in situ DPASV of Bi+3 ions in the presence of tamoxifen shown the optimal conditions as: 2 mol L-1 H2SO4 (1% v v-1 MeOH), a deposition potential of -0.5 V, a deposition time of 60 s, and a glassy carbon electrode rotation rate of 300 rpm. The calibration curve was plotted in the range of 0.5 to 6 µg mL-1 and the limits of detection and quantitation were calculated to be 3.1 × 10-5 µg mL-1 and 1.0 × 10-4 µg mL-1, respectively. The mean, RSD, and relative bias for 0.5 µg mL-1 (n=5) were found to be 0.49 µg mL-1, 0.3%, and 2%, respectively. Finally, the proposed method was successfully used for the determination of tamoxifen in serum and pharmaceutical samples.


2019 ◽  
Vol Vol. 14, No.1 ◽  
pp. 5-14 ◽  
Author(s):  
Anastasiya Tkachenko ◽  
Mykyta Onizhuk ◽  
Oleg Tkachenko ◽  
Leliz T. Arenas ◽  
Edilson V. Benvenutt ◽  
...  

In the present study, an electrochemical sensor based on the electrode (SiMImCl/C) consisting of graphite and silica, grafted with 1-n-propyl-3-methylimidazolium chloride was used for ascorbic acid (AA) quantification in pharmaceuticals and food formulations. Cyclic voltammetry and electrochemical impedance spectroscopy were applied for electrochemical characterization of the SiMImCl/C electrode. The cyclic voltammetry study revealed that the oxidation of AA on this electrode is an irreversible process, realized by adsorption and diffusion limited step. The differential pulse voltammetry was applied to develop a procedure for the AA determination. The linear range was found to be 0.3–170 μmol L-1 and the limit of detection – 0.1 μmol L-1. The proposed SiMImCl/C electrode has long term stability and does not show electrochemical activity towards the analytes, which commonly coexist with AA. The sensor was successfully used for quantification of AA in food and pharmaceutical formulations.