Do we measure bilirubin correctly anno 2005?

Author(s):  
Joke J. Apperloo ◽  
Fedde van der Graaf ◽  
Volkher Scharnhorst ◽  
Huib L. Vader

AbstractWe observed 30% discrepancy between liquid chemistry and dry chemistry analysers for the determination of total bilirubin in human adult serum samples, which were consistent with a 20% overestimation and 10% underestimation relative to a Jendrassik-Grof reference method, respectively. In contrast, standard reference material SRM916, which was recently recommended as being the most suitable material for attaining interlaboratory agreement, shows very good agreement on both types of analysers, as well as close to 100% recovery with respect to the reference method. We show that the liquid vs. dry bilirubin discrepancies seem to originate in the presence of either conjugated or δ-bilirubin. Our observations make it clear that good interlaboratory (or inter-analyser) agreement between bilirubin reference materials does not guarantee the same for bilirubin concentrations in human serum samples.

1992 ◽  
Vol 38 (8) ◽  
pp. 1459-1465 ◽  
Author(s):  
P C Gunaratna ◽  
W F Koch ◽  
R C Paule ◽  
A D Cormier ◽  
P D'Orazio ◽  
...  

Abstract Three interlaboratory round-robin studies (RR1, RR2, and RR3) were conducted to identify a serum-based reference material that would aid in the standardization of direct ion-selective electrode (ISE) measurements of sodium and potassium. Ultrafiltered frozen serum reference materials requiring no reconstitution reduced between-laboratory variability (the largest source of imprecision) more than did other reference materials. ISE values for RR3 were normalized by the use of two points at the extremes of the clinical range for sodium (i.e., 120 and 160 mmol/L), with values assigned by the flame atomic emission spectrometry (FAES) Reference Method. This FAES normalization of ISE raw values remarkably improved all sources of variability and unified the results from seven different direct ISE analyzers to the FAES Reference Method value. Subsequently, a three-tiered, fresh-frozen human serum reference material was produced to the specifications developed in RR1-RR3, was assigned certified values for sodium and potassium by Definitive Methods at the National Institute of Standards and Technology (NIST), and was made available in 1990 to the clinical laboratory community as a Standard Reference Material (SRM); it is now identified as SRM 956. Albeit retrospectively, we show how applying an FAES normalization step identical to that used in RR4/5 to the ISE data for SRM 956 after the NIST Definitive Method values were known, consistently moved the ISE results for RR3 closer to the true value for Na+ and K+.


Author(s):  
Hina Shamshad ◽  
Ali Sayqal ◽  
Jahan Zeb ◽  
Agha Zeeshan Mirza

Abstract A simple, accurate and precise RP-HPLC method was developed for the simultaneous determination of chloroquine, pyrimethamine and cetirizine hydrochloride concentrations in bulk drug and human serum. The assay was performed using a mobile phase of methanol: water (70:30) at pH of 2.8 ± 0.05 on the Purospher C-18 column with UV detection at 230 nm and rosuvastatin used as an internal standard. The retention times observed for chloroquine, pyrimethamine and cetirizine hydrochloride were 3.5, 2.5 and 5.5 minutes, respectively. The method was found to be specific for the assayed drugs showing a linear response in the concentration range of 1–100 μg mL−1 with coefficients of determination values of (r = 0.999). The method was developed and validated according to ICH guidelines. The method was used to monitor the serum samples and was found to be sensitive for therapeutic purposes, showing the potential to be a useful tool for routine analysis in laboratories.


2016 ◽  
Vol 129 ◽  
pp. 205-212 ◽  
Author(s):  
Adrian Marcelo Granero ◽  
Gastón Darío Pierini ◽  
Sebastián Noel Robledo ◽  
María Susana Di Nezio ◽  
Héctor Fernández ◽  
...  

2011 ◽  
Vol 6 ◽  
pp. ACI.S7346 ◽  
Author(s):  
Ani Mulyasuryani ◽  
Arie Srihardiastutie

A conductimetric enzyme biosensor for uric acid detection has been developed. The uricase, as enzyme, is isolated from Candida utilis and immobilized on a nata de coco membrane-Pt electrode. The biosensor demonstrates a linear response to urate over the concentration range 1-6 ppm and has good selectivity properties. The response is affected by the membrane thickness and pH change in the range 7.5-9.5. The response time is three minutes in aqueous solutions and in human serum samples. Application of the biosensor to the determination of uric acid in human serum gave results that compared favourably with those obtained by medical laboratory. The operational stability of the biosensor was not less than three days and the relative error is smaller than 10%.


2004 ◽  
Vol 516 (1-2) ◽  
pp. 135-140 ◽  
Author(s):  
José Luis Vı́lchez ◽  
Lilia Araujo ◽  
Avismelsi Prieto ◽  
Alberto Navalón

2017 ◽  
Author(s):  
Jeanice Brown Thomas ◽  
David L Duewer ◽  
Carolyn Q Burdette ◽  
Lorna T Sniegoski ◽  
James H Yen

2020 ◽  
Vol 35 (Supplement_3) ◽  
Author(s):  
Laura Sponton ◽  
Hulin Jin ◽  
Markus Fluck ◽  
Yusuke Suzuki ◽  
Amy Kao

Abstract Background and Aims Analysis of serum or plasma from patients with IgA nephropathy (IgAN) has confirmed the presence of elevated levels of circulating immune complexes containing Gd-IgA1 (Czerkinsky 1986). New sensitive and reasonably specific noninvasive tests are emerging to guide the therapeutic strategy that is applicable to all stages of IgAN (Suzuki 2014). Here we are reporting the fit for purpose validation of an ELISA method for the quantitative determination of Gd-IgA1 in human serum samples to support biomarker investigations in clinical studies of Merck KGaA, Darmstadt. Method The assay was developed based on a commercially available immunoassay kit. The dynamic range of the calibration curve was determined from 1.56 ng/mL (LLOQ) to 100 ng/mL (ULOQ). With a minimum required dilution of 200-fold and standard assay volume of 50.0 μL, the range of the method in matrix was from 312 ng/mL to 20, 000 ng/mL. In assay validation phase, multiple validation parameters were evaluated, which included minimum required dilution (MRD), calibration curve, matrix effect, Intra- & Inter run accuracy & precision, selectivity, and parallelism. Additional validation parameters include sample stability (short/long term, freeze-thaw) and batch-to-batch comparison. Results All samples measured for intra & Inter - assay precision, accuracy, fulfilled the specifications according to the acceptance criteria. The selectivity was assessed using blank serum matrix from 10 individuals: the result indicated that matrix components in serum did not interfere with the detection of Gd-IgA1. Parallelism assessment was performed successfully for both samples from healthy donors and IgAN patient samples up to dilution factor (DF) 3200 (serum samples from healthy donors were determined up to DF 1600). All DF-corrected results within the assay range were determined with %CV ≤ 30.0%. Batch to batch comparison was assessed successfully based on the known shelf life of the kit. Short term stability using QC samples were given for up to 24hrs at room temperature. Freeze-thaw stability was given for up to 3 cycles at -20°C±5°C and -75°C±15°C. The investigations were performed according to general guidelines for method validation and applicable regulations. The results of investigated validation parameters fulfilled the requirements and recommendations, generally accepted for bioanalytical projects. Conclusion The present validation qualified the method for the quantitative determination of Gd-IgA1 in human serum samples from clinical studies.


2011 ◽  
Vol 84 (2) ◽  
pp. 956-962 ◽  
Author(s):  
Karen W. Phinney ◽  
Mary Bedner ◽  
Susan S.-C. Tai ◽  
Veronica V. Vamathevan ◽  
Lane C. Sander ◽  
...  