scholarly journals E. coli and enterococci subtyping to discriminate contamination sources in wastewater treatment ponds

Author(s):  
Arnau Casanovas-Massana ◽  
◽  
Anicet Blanch ◽  
Membranes ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 221
Author(s):  
Rafał Tytus Bray ◽  
Katarzyna Jankowska ◽  
Eliza Kulbat ◽  
Aneta Łuczkiewicz ◽  
Aleksandra Sokołowska

The paper presents the results of research on the use of ultrafiltration, using membranes of 200 and 400 kDa separation, for disinfection of municipal treated wastewater. The research was conducted on a fractional technical scale using real municipal treated wastewater from two large wastewater treatment plants treating most of the wastewater over the one-million polycentric Gdańsk agglomeration (1.2 million inhabitants). UF 200 kDa and UF 400 kDa processes enabled further improvement of the physical and chemical parameters of treated wastewater. Total phosphorus (to below 0.2 mg/L–UF 200 kDa, 0.13 mg/L–UF 400 kDa) and turbid substances (to below 0.2 mg/L, both membranes) were removed in the highest degree. COD was reduced efficiently (to below 25.6 mgO2/L–UF 200 kDa, 26.8 mgO2/L–UF 400 kDa), while total nitrogen was removed to a small extent (to 7.12 mg/L–UF 200 kDa and 5.7 mg/L–UF 400 kDa. Based on the reduction of indicator bacteria; fecal coliforms including E. coli (FC) and fecal enterococci (FE) it was found that the ultrafiltration is an effective method of disinfection. Not much indicator bacterial were observed in the permeate after processes (UF 200 kDa; FC—5 CFU/L; FE—1 CFU/L and UF 400 kDa; FC—70 CFU/L; FE—10 CFU/L. However, microscopic analysis of prokaryotic cells and virus particles showed their presence after the application of both membrane types; TCN 3.0 × 102 cells/mL–UF 200 kDa, 5.0 × 103 cells/mL–UF 400 kDa, VP 1.0 × 105/mL. The presence of potentially pathogenic, highly infectious virus particles means that ultrafiltration cannot be considered a sufficient disinfection method for treated wastewater diverted for reuse or discharged from high load wastewater treatment plants to recreational areas. For full microbiological safety it would be advisable to apply an additional disinfection method (e.g., ozonation).


Author(s):  
Maria Clara V. M. Starling ◽  
Elizângela P. Costa ◽  
Felipe A. Souza ◽  
Elayne C. Machado ◽  
Juliana Calábria de Araujo ◽  
...  

AbstractThis work investigated an innovative alternative to improve municipal wastewater treatment plant effluent (MWWTP effluent) quality aiming at the removal of contaminants of emerging concern (caffeine, carbendazim, and losartan potassium), and antibiotic-resistant bacteria (ARB), as well as disinfection (E. coli). Persulfate was used as an alternative oxidant in the solar photo-Fenton process (solar/Fe/S2O82−) due to its greater stability in the presence of matrix components. The efficiency of solar/Fe/S2O82− at neutral pH using intermittent iron additions is unprecedented in the literature. At first, solar/Fe/S2O82− was performed in a solar simulator (30 W m−2) leading to more than 60% removal of CECs, and the intermittent iron addition strategy was proved effective. Then, solar/Fe/S2O82− and solar/Fe/H2O2 were compared in semi-pilot scale in a raceway pond reactor (RPR) and a cost analysis was performed. Solar/Fe/S2O82− showed higher efficiencies of removal of target CECs (55%), E. coli (3 log units), and ARB (3 to 4 log units) within 1.9 kJ L−1 of accumulated irradiation compared to solar/Fe/H2O2 (CECs, 49%; E. coli, 2 log units; ARB, 1 to 3 log units in 2.5 kJ L−1). None of the treatments generated acute toxicity upon Allivibrio fischeri. Lower total cost was obtained using S2O82− (0.6 € m−3) compared to H2O2 (1.2 € m−3). Therefore, the iron intermittent addition aligned to the use of persulfate is suitable for MWWTP effluent quality improvement at neutral pH.


2012 ◽  
Vol 65 (4) ◽  
pp. 589-595 ◽  
Author(s):  
A. Ouali ◽  
H. Jupsin ◽  
J. L. Vasel ◽  
L. Marouani ◽  
A. Ghrabi

Korba wastewater treatment plant is a conventional activated sludge followed by three maturation ponds (MP1, MP2, MP3) in series acting as a tertiary treatment. The first study of wastewater treatment plants showed that the effluent concentration of Escherichia coli and enterococci at the outlet of the (MP3) varies between 103 and 104CFU/100 ml. After the hydrodynamic study conducted by Rhodamine WT which showed short-circuiting in the MP1, two baffles were introduced in the first maturation pond (MP1) to improve the hydrodynamic and the sanitary performances. The second hydraulic study showed that the dispersion number ‘d’ was reduced from 1.45 to 0.43 by this engineering intervention and the Peclet number was raised from 0.69 to 2.32. The hydraulic retention time was increased by 14 h. Because of well-designed baffles, the removal efficiency of E. coli and enterococci was raised between 0.2 and 0.7 log units for the first maturation pond.


2010 ◽  
Vol 61 (6) ◽  
pp. 1383-1392 ◽  
Author(s):  
A. Łuczkiewicz ◽  
S. Fudala-Książek ◽  
K. Jankowska ◽  
B. Quant ◽  
K. Olańczuk-Neyman

The occurrence of resistance patterns among wastewater fecal coliforms was determined in the study. Susceptibility of the isolates was tested against 19 antimicrobial agents: aminoglycosides, aztreonam, carbapenems, cephalosporines, β-lactam/β-lactamase inhibitors, penicillines, tetracycline, trimethoprim/sulfamethoxazole, and fluoroquinolones. Additionally the removal of resistant isolates was evaluated in the laboratory-scale wastewater treatment model plant (M-WWTP), continuously supplied with the wastewater obtained from the full-scale WWTP. Number of fecal coliforms in raw (after mechanical treatment) and treated wastewater, as well as in aerobic chamber effluent was determined using selective medium. The selected strains were identified and examined for antibiotic resistance using Phoenix Automated Microbiology System (BD Biosciences, USA). The strains were identified as Escherichia coli (n = 222), Klebsiella pneumoniae ssp. ozaenae (n = 9), and Pantoea agglomerans (n = 1). The isolate of P. agglomerans as well as 48% of E. coli isolates were sensitive to all antimicrobials tested. The most frequent resistance patterns were found for ampicillin: 100% of K. pneumoniae ssp. ozaenae and 41% of E. coli isolates. Among E. coli isolates 12% was regarded as multiple antimicrobial resistant (MAR). In the studied M-WWTP, the applied activated sludge processes reduced considerably the number of fecal coliforms, but increased the ratio of antimicrobial-resistant E. coli isolates to sensitive ones, especially among strains with MAR patterns.


Author(s):  
Katelyn Sellgren ◽  
◽  
Christopher Gregory ◽  
Michael Hunt ◽  
Ashkay Raut ◽  
...  

Electrochemical disinfection has gained interest as an alternative to conventional wastewater treatment because of its high effectiveness and environmental compatibility. Two and a half billion people currently live without improved sanitation facilities. Our research efforts are focused on developing and implementing a freestanding, additive-free toilet system that treats and recycles blackwater on site. In this study, we sought to apply electrochemical disinfection to blackwater. We compared commercially available boron-doped diamond (BDD) and mixed metal oxide (MMO) electrodes for disinfection efficiency in E. coli–inoculated model wastewater. The MMO electrodes were found to be more efficient and thus selected for further study with blackwater. The energy required for disinfection by the MMO electrodes increased with the conductivity of the medium, decreased with increased temperature, and was independent of the applied voltage. Fecal contamination considerably increased the energy required for blackwater disinfection compared to model wastewater, demonstrating the need for testing in effluents representing the conditions of the final application.


2015 ◽  
Vol 72 (10) ◽  
pp. 1851-1860 ◽  
Author(s):  
Charles Humphrey ◽  
Algernon Finley ◽  
Michael O'Driscoll ◽  
Alex Manda ◽  
Guy Iverson

The goal of this study was to determine if onsite wastewater treatment systems (OWS) were influencing groundwater and surface water Escherichia coli concentrations in a coastal plain watershed. Piezometers for groundwater monitoring were installed at four residences served by OWS and five residences served by a municipal wastewater treatment system (MWS). The residences were located in two different, but nearby (<3 km), watersheds. Effluent from the four septic tanks, groundwater from piezometers, and the streams draining the OWS and MWS watersheds were sampled on five dates between September 2011 and May 2012. Groundwater E. coli concentrations and specific conductivity were elevated within the flow path of the OWS and near the stream, relative to other groundwater sampling locations in the two watersheds. Groundwater discharge in the OWS watershed could be a contributor of E. coli to the stream because E. coli concentrations in groundwater at the stream bank and in the stream were similar. Stream E. coli concentrations were higher for the OWS in relation to MWS watersheds on each sampling date. Water quality could be improved by ensuring OWS are installed and operated to maintain adequate separation distances to water resources.


2018 ◽  
Vol 73 ◽  
pp. 05018
Author(s):  
Nurcholis ◽  
Dirwan Muchlis

The purpose of this research is to know the contamination of waste water that happened in slaughterhouse (RPH) city of merauke. Data were obtained based on surveys and field observations and the sample used was RPH water waste each in repeat as many as 6 replications. Data analysis was done descriptively by comparing the result obtained with the standard of quality which have been determined. The results showed that the contamination of waste water all exceeded the quality standard except at pH value. The ALT content of wastewater in RPH 2790 x 104 and contains E. Coli and Salmonella microbes. The high content of BOD, COD, TTS, Ammonia and microbial contamination is thought to be due to the absence of wastewater treatment installation (IPAL) at RPH in accordance with the standard. Proper handling of ammonia waste can reduce the amount of carbon in the atmosphere.


2020 ◽  
Vol 86 (8) ◽  
Author(s):  
Mykhailo Savin ◽  
Gabriele Bierbaum ◽  
Jens Andre Hammerl ◽  
Céline Heinemann ◽  
Marijo Parcina ◽  
...  

ABSTRACT The wastewater of livestock slaughterhouses is considered a source of antimicrobial-resistant bacteria with clinical relevance and may thus be important for their dissemination into the environment. To get an overview of their occurrence and characteristics, we investigated process water (n = 50) from delivery and unclean areas as well as wastewater (n = 32) from the in-house wastewater treatment plants (WWTPs) of two German poultry slaughterhouses (slaughterhouses S1 and S2). The samples were screened for ESKAPE bacteria (Enterococcus spp., Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, Enterobacter spp.) and Escherichia coli. Their antimicrobial resistance phenotypes and the presence of extended-spectrum-β-lactamase (ESBL), carbapenemase, and mobilizable colistin resistance genes were determined. Selected ESKAPE bacteria were epidemiologically classified using different molecular typing techniques. At least one of the target species was detected in 87.5% (n = 28/32) of the wastewater samples and 86.0% (n = 43/50) of the process water samples. The vast majority of the recovered isolates (94.9%, n = 448/472) was represented by E. coli (39.4%), the A. calcoaceticus-A. baumannii (ACB) complex (32.4%), S. aureus (12.3%), and K. pneumoniae (10.8%), which were widely distributed in the delivery and unclean areas of the individual slaughterhouses, including their wastewater effluents. Enterobacter spp., Enterococcus spp., and P. aeruginosa were less abundant and made up 5.1% of the isolates. Phenotypic and genotypic analyses revealed that the recovered isolates exhibited diverse resistance phenotypes and β-lactamase genes. In conclusion, wastewater effluents from the investigated poultry slaughterhouses exhibited clinically relevant bacteria (E. coli, methicillin-resistant S. aureus, K. pneumoniae, and species of the ACB and Enterobacter cloacae complexes) that contribute to the dissemination of clinically relevant resistances (i.e., blaCTX-M or blaSHV and mcr-1) in the environment. IMPORTANCE Bacteria from livestock may be opportunistic pathogens and carriers of clinically relevant resistance genes, as many antimicrobials are used in both veterinary and human medicine. They may be released into the environment from wastewater treatment plants (WWTPs), which are influenced by wastewater from slaughterhouses, thereby endangering public health. Moreover, process water that accumulates during the slaughtering of poultry is an important reservoir for livestock-associated multidrug-resistant bacteria and may serve as a vector of transmission to occupationally exposed slaughterhouse employees. Mitigation solutions aimed at the reduction of the bacterial discharge into the production water circuit as well as interventions against their further transmission and dissemination need to be elaborated. Furthermore, the efficacy of in-house WWTPs needs to be questioned. Reliable data on the occurrence and diversity of clinically relevant bacteria within the slaughtering production chain and in the WWTP effluents in Germany will help to assess their impact on public and environmental health.


2011 ◽  
Vol 64 (5) ◽  
pp. 1032-1039 ◽  
Author(s):  
S. Barbagallo ◽  
G. L. Cirelli ◽  
A. Marzo ◽  
M. Milani ◽  
A. Toscano

This work focuses on the performance evaluation of two full-scale horizontal suburface flow constructed wetlands (H-SSF CWs) working in parallel, which have an almost equal surface area (about 2,000 m2) but with different operational lives: 8 and 3 years. Both H-SSF CWs, located in Southern Italy (Sicily), are used for tertiary treatment of the effluent of a conventional wastewater treatment plant. This study evaluates and compares H-SSF CW efficiency both in terms of water quality improvement (removal percentage) and achievement of Italian wastewater discharge and irrigation reuse limits. The mean removal percentage, for the overall operational life, of TSS, COD and BOD (80%, 63%, 58% obtained for H-SSF1 and 67%, 38%, 41% for H-SSF2), confirm the high reliability of CWs for wastewater treatment. However, despite the satisfactory removal of microbial indicators (the mean E. coli removal was up to 2.5 log unit for both beds), CWs didn't achieve the Italian limits for wastewater reuse. Information on hydraulic properties of the CWs were extracted from breakthrough curves of a non-reactive tracer (NaCl). By comparing the nominal (τn) and actual residence time (τ), hydraulic behaviour was revealed.


2013 ◽  
Vol 12 (1) ◽  
pp. 196-209 ◽  
Author(s):  
H. S. Lim ◽  
L. Y. Lee ◽  
S. E. Bramono

This paper examines the impact of community-based water treatment systems on water quality in a peri-urban village in Yogyakarta, Indonesia. Water samples were taken from the wastewater treatment plants (WWTPs), irrigation canals, paddy fields and wells during the dry and wet seasons. The samples were tested for biological and chemical oxygen demand, nutrients (ammonia, nitrate, total nitrogen and total phosphorus) and Escherichia coli. Water quality in this village is affected by the presence of active septic tanks, WWTP effluent discharge, small-scale tempe industries and external sources. We found that the WWTPs remove oxygen-demanding wastes effectively but discharged nutrients, such as nitrate and ammonia, into irrigation canals. Irrigation canals had high levels of E. coli as well as oxygen-demanding wastes. Well samples had high E. coli, nitrate and total nitrogen levels. Rainfall tended to increase concentrations of biological and chemical oxygen demand and some nutrients. All our samples fell within the drinking water standards for nitrate but failed the international and Indonesian standards for E. coli. Water quality in this village can be improved by improving the WWTP treatment of nutrients, encouraging more villagers to be connected to WWTPs and controlling hotspot contamination areas in the village.


Sign in / Sign up

Export Citation Format

Share Document