scholarly journals Experimental measurements of a prototype high concentration Fresnel lens CPV module for the harvesting of diffuse solar radiation

2013 ◽  
Vol 22 (S1) ◽  
pp. A28 ◽  
Author(s):  
Noboru Yamada ◽  
Kazuya Okamoto
Atmosphere ◽  
2021 ◽  
Vol 12 (4) ◽  
pp. 524
Author(s):  
Jihui Yuan ◽  
Kazuo Emura ◽  
Craig Farnham

The Typical meteorological year (TMY) database is often used to calculate air-conditioning loads, and it directly affects the building energy savings design. Among four kinds of TMY databases in China—including Chinese Typical Year Weather (CTYW), International Weather for Energy Calculations (IWEC), Solar Wind Energy Resource Assessment (SWERA) and Chinese Standard Weather Data (CSWD)—only CSWD is measures solar radiation, and it is most used in China. However, the solar radiation of CSWD is a measured daily value, and its hourly value is separated by models. It is found that the cloud ratio (diffuse solar radiation divided by global solar radiation) of CSWD is not realistic in months of May, June and July while compared to the other sets of TMY databases. In order to obtain a more accurate cloud ratio of CSWD for air-conditioning load calculation, this study aims to propose a method of refining the cloud ratio of CSWD in Shanghai, China, using observed solar radiation and the Perez model which is a separation model of high accuracy. In addition, the impact of cloud ratio on air-conditioning load has also been discussed in this paper. It is shown that the cloud ratio can yield a significant impact on the air conditioning load.


Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4301
Author(s):  
Yassir A. Alamri ◽  
Saad Mahmoud ◽  
Raya Al-Dadah ◽  
Shivangi Sharma ◽  
J. N. Roy ◽  
...  

This paper investigates the potential of a new integrated solar concentrated photovoltaic (CPV) system that uses a solo point focus Fresnel lens for multiple multi-junction solar cells (MJSCs). The proposed system comprises of an FL concentrator as the primary optical element, a multi-leg homogeniser as the secondary optical element (SOE), a plano-concave lens, and four MJSCs. A three-dimensional model of this system was developed using the ray tracing method to predict the influence of aperture width, height, and position with respect to MJSCs of different reflective and refractive SOE on the overall optical efficiency of the system and the irradiance uniformity achieved on the MJSCs’ surfaces. The results show that the refractive homogeniser using N-BK7 glass can achieve higher optical efficiency (79%) compared to the reflective homogeniser (57.5%). In addition, the peak to average ratio of illumination at MJSCs for the reflective homogeniser ranges from 1.07 to 1.14, while for the refractive homogeniser, it ranges from 1.06 to 1.34, causing minimum effects on the electrical performance of the MJSCs. The novelty of this paper is the development of a high concentration CPV system that integrates multiple MJSCs with a uniform distribution of rays, unlike the conventional CPV systems that utilise a single concentrator onto a single MJSC. The optical efficiency of the CPV system was also examined using both the types of homogeniser (reflective and refractive).


2006 ◽  
Vol 129 (3) ◽  
pp. 298-303 ◽  
Author(s):  
V. M. Andreev ◽  
A. S. Vlasov ◽  
V. P. Khvostikov ◽  
O. A. Khvostikova ◽  
P. Y. Gazaryan ◽  
...  

Results of a solar thermophotovoltaic (STPV) system study are reported. Modeling of the STPV module performance and the analysis of various parameters influencing the system are presented. The ways for the STPV system efficiency to increase and their magnitude are considered such as: improvement of the emitter radiation selectivity and application of selective filters for better matching the emitter radiation spectrum and cell photoresponse; application of the cells with a back side reflector for recycling the sub-band gap photons; and development of low-band gap tandem TPV cells for better utilization of the radiation spectrum. Sunlight concentrator and STPV modules were designed, fabricated, and tested under indoor and outdoor conditions. A cost-effective sunlight concentrator with Fresnel lens was developed as a primary concentrator and a secondary quartz meniscus lens ensured the high concentration ratio of ∼4000×, which is necessary for achieving the high efficiency of the concentrator–emitter system owing to trap escaping radiation. Several types of STPV modules have been developed and tested under concentrated sunlight. Photocurrent density of 4.5A∕cm2 was registered in a photoreceiver based on 1×1cm2GaSb cells under a solar powered tungsten emitter.


2005 ◽  
Vol 128 (1) ◽  
pp. 104-117 ◽  
Author(s):  
T. Muneer ◽  
S. Munawwar

Solar energy applications require readily available, site-oriented, and long-term solar data. However, the frequent unavailability of diffuse irradiation, in contrast to its need, has led to the evolution of various regression models to predict it from the more commonly available data. Estimating the diffuse component from global radiation is one such technique. The present work focuses on improvement in the accuracy of the models for predicting horizontal diffuse irradiation using hourly solar radiation database from nine sites across the globe. The influence of sunshine fraction, cloud cover, and air mass on estimation of diffuse radiation is investigated. Inclusion of these along with hourly clearness index, leads to the development of a series of models for each site. Estimated values of hourly diffuse radiation are compared with measured values in terms of error statistics and indicators like, R2, mean bias deviation, root mean square deviation, skewness, and kurtosis. A new method called “the accuracy score system” is devised to assess the effect on accuracy with subsequent addition of each parameter and increase in complexity of equation. After an extensive evaluation procedure, extricate but adequate models are recommended as optimum for each of the nine sites. These models were found to be site dependent but the model types were fairly consistent for neighboring stations or locations with similar climates. Also, this study reveals a significant improvement from the conventional k-kt regression models to the presently proposed models.


2021 ◽  
pp. 1-29
Author(s):  
Kuldeep Awasthi ◽  
Desireddy Shashidhar Reddy ◽  
Mohd. Kaleem Khan

Abstract This paper describes the design methodology for a novel Fresnel lens. The original Fresnel lens is obtained from a plano-convex lens, whose spherical surface is split into a number of divisions (called facets), collapsed onto the flat base. Thus, all the facets of the original Fresnel lens have the same radius as that of the plano-convex lens. The proposed design aims to achieve better ray concentration and reduced spherical aberration than the original Fresnel lens by constructing spherical facets with unequal radii. The centers and radii of facets are constrained so that the ray refracted from the bottom vertex of each facet on one side of the optical axis and the ray refracted from the outer vertex of the corresponding facet on the other side of the optical axis must intersect at the focal plane. The proposed lens design has resulted in a 275% gain in the concentration ratio and a 72.5% reduction in the spherical aberration compared to the original lens of the same aperture diameter and number of facets. The performance of both novel and original Fresnel lenses when used as solar concentrators with a conical coil receiver is evaluated. The novel Fresnel lens led to increased heat gain and resulted in a compact solar collector design.


Sign in / Sign up

Export Citation Format

Share Document