A new fluorometric and optical approach for tracking of intracellular calcium, blood volume and oxygenation changes in the rat brain in vivo

Author(s):  
Congwu Du ◽  
Igor Izrailtyan ◽  
Helene Benveniste
2005 ◽  
Vol 25 (8) ◽  
pp. 1078-1092 ◽  
Author(s):  
Congwu Du ◽  
Alan P Koretsky ◽  
Igor Izrailtyan ◽  
Helene Benveniste

We describe an approach to measure changes in intracellular calcium along with changes in blood volume and oxygenation directly from the exposed rat cortex in vivo during cerebral ischemia and reperfusion. Measurements were made using a catheter-based optical system. The endface of a Y-shaped bifurcated fiber optic bundle was mounted on the cortical surface. It delivered the light at three wavelengths of 548, 555, and 572 nm to the brain through a fast monochromator coupled to a xenon lamp, and collected the calcium-dependent fluorescence emission from Rhod2 at 589 nm (excited at 548 nm) along with the diffuse reflections at the wavelengths of 555 and 572 nm to determine the changes in blood volume and hemoglobin oxygenation. The feasibility of this approach was experimentally examined by inducing transient cerebral ischemia and reperfusion in the rat. The ischemia induced an 8.5%±1.7% fluorescence increase compared with the preischemic control values. Blood volume and tissue hemoglobin oxygenation decreased by 57.4%±12.6% and 47.3%±12.5%, respectively. All signals normalized on reperfusion. The ischemia-induced change in Rhod2-Ca2+ fluorescence was blocked using a calcium channel blocker, nimodipine, confirming that intracellular changes in calcium were responsible for the fluorescence changes. Thus, changes in cerebral hemodynamics and intracellular calcium concentration changes were measured simultaneously, facilitating future studies of the interrelationship between neuronal activation and metabolic and vascular processes in normal and diseased brain.


2005 ◽  
Vol 25 (1_suppl) ◽  
pp. S468-S468
Author(s):  
Jennifer K Callaway ◽  
Christine Molnar ◽  
Song T Yao ◽  
Bevyn Jarrott ◽  
R David Andrew

2013 ◽  
Vol 44 (S 01) ◽  
Author(s):  
M Breu ◽  
D Reisinger ◽  
D Wu ◽  
Y Zhang ◽  
A Fatemi ◽  
...  

1981 ◽  
Vol 45 (03) ◽  
pp. 208-210 ◽  
Author(s):  
D Green ◽  
S M Spies ◽  
N A Rana ◽  
J W Milgram ◽  
R Mintzer

SummaryThe technique of blood pool scanning was used to examine 15 hemophilic subjects. Employing an in vivo method for erythrocyte labeling with Technetium-99 m, a dynamic perfusion sequence is obtained using a scintillation camera positioned over the area to be examined. This demonstrates the vascularity of the tissue. Subsequently, equilibrium blood pool images of the area are obtained and analyzed with a densitometer to assess relative regional blood volume. In patients who were not bleeding but had chronic arthropathy, vascularity was not increased, and the blood volume of comparable joints was similar. By contrast, marked increases in vascularity and image density were observed in studies of acutely bleeding joints. Chronic hemarthroses were associated with persistent, but less marked increases in joint perfusion. Transient increases in joint vascularity were demonstrated after insertion of knee prostheses. In a patient with a thigh hematoma, the dimensions of the hemorrhage were clearly delineated. Since only a tracer dose of nuclide is infused intravenously, there are no allergic reactions or other side effects of the procedure. Blood pool scanning is a safe, non-invasive technique that augments clinical and radiographic evaluations, and provides a new dimension in the assessment of the hemophilic patient.


1962 ◽  
Vol 237 (3) ◽  
pp. 803-806
Author(s):  
Gordon Guroff ◽  
Sidney Udenfriend

Sign in / Sign up

Export Citation Format

Share Document