Protected Agriculture in Extreme Environments: A Review of Controlled Environment Agriculture in Tropical, Arid, Polar, and Urban Locations

2018 ◽  
Vol 34 (2) ◽  
pp. 455-473 ◽  
Author(s):  
Lucas McCartney ◽  
Mark Lefsrud

Abstract. Many methods of protected agriculture are used to modify the growing environment of plants. Ideally, plant production would take place in regions that do not require protective structures, regions that present ideal temperatures, no harsh extremes, and sufficient but not excess precipitation. This is not the case however, as most countries, save for a select few, require various forms of controlled environment agriculture to protect crops against climatic and environmental extremes. Although the greenhouse industry has developed vast amounts of technology for the temperate climate regions of our planet, much remains to be improved in terms of protected agriculture in the more extreme climates. Tropical, arid, polar and urban locations offer contrasting environments that present various challenges for plant growth. Some challenges are specific to each location, while others are common across them. Tropical and arid climates offer high solar radiation, but present harsh temperature and relative humidity conditions. Most protected agriculture structures are relatively open in nature to ventilate and discharge heat, but are susceptible to pests and diseases. On the other hand, polar climates and urban environments often lack solar radiation and require a high level of control of the air quality. The structures used in these environments are relatively enclosed to entrap heat (polar) and to make efficient use of space. The sustainability of available technologies and energy efficiency are important themes present in all discussed climates and environments. Protected agriculture technologies offer solutions to growers in locations with extreme climates wishing to produce high yields of high quality crop, and this article presents a review of the existing challenges and of the advancements made in this field. Keywords: Arid climate greenhouse, Evaporative cooling, Natural ventilation, Protected agriculture, Tropical climate greenhouse, Urban agriculture, Vertical farming.

2016 ◽  
Vol 50 (2) ◽  
pp. 101-113 ◽  
Author(s):  
Masahisa ISHII ◽  
Sadanori SASE ◽  
Hideki MORIYAMA ◽  
Limi OKUSHIMA ◽  
Atsuo IKEGUCHI ◽  
...  

2021 ◽  
pp. 1420326X2110160
Author(s):  
Kai Yip Lee ◽  
Cheuk Ming Mak

This study investigated effects of incident wind angles on wind velocity distributions in wakes of two generic building configurations, namely, ‘T’- and ‘+’-shaped, and the air pressure distributions along their leeward walls by using computational fluid dynamics simulations. Results show that when the wind approaches laterally (90°) (vs. when the wind is direct (0°)), the downwind length and maximum bilateral width of the low-wind velocity zone in the wake of ‘T’-shaped building decrease by 11.5% and 37.9%, respectively. When the incident wind is oblique (45°) (vs. when it is direct), the length and width of this low-wind velocity zone in the wake of ‘+’-shaped building decrease by 15.0% and 30.9%, respectively. Furthermore, results show that the air pressure on the leeward walls of the ‘T’- and ‘+’-shaped buildings gradually decreases along with the building height. The resulting low-wind conditions on upper floors of buildings reduce the fresh air intake of their leeward units utilizing natural ventilation. It is particularly apparent in the case of direct approaching wind. Thus, the appropriate selection of building configurations and their orientations allows for the most effective use of wind to enhance ventilation in indoor and urban environments.


2018 ◽  
Vol 63 (1) ◽  
pp. 57-66
Author(s):  
Balázs Bokor ◽  
Hacer Akhan ◽  
Dogan Eryener ◽  
László Kajtár

Transpired solar collector (TSC) systems are simple solutions for the preheating of ventilation air with solar energy. Their performance is a function of several environmental factors, so the climatic conditions of the location play an important role. In this paper, the effect of different climatic zones on the thermal performance of the TSC is investigated. To exclude other sources of influence, the same reference industrial building is examined in four Turkish locations (Antalya, Istanbul, Ankara and Sivas) representing different climatic conditions. RETScreen simulation is carried out for all four regions to obtain the drop of conventional heating requirement in case absorber azimuth of 0°, 45° and 90°. To illustrate the performance, temperature rise, heating energy savings and annual solar fraction are presented. Generally, it can be stated that a location with cold climate and high solar radiation at the same time benefits most from the use of a TSC system. A mathematical correlation has been found showing the solar fraction's dependence on solar radiation and heating degree days. Finally, simulation results have been compared to a set of measurement data from an industrial building's TSC system near Istanbul.


2019 ◽  
Vol 199 ◽  
pp. 191-199 ◽  
Author(s):  
Hidenori Otani ◽  
Mitsuharu Kaya ◽  
Akira Tamaki ◽  
Heita Goto ◽  
Ronald J. Maughan

Sign in / Sign up

Export Citation Format

Share Document