scholarly journals 4D-CT: A new development in three-dimensional hepatic computed tomography

2000 ◽  
Vol 67 (1) ◽  
pp. 24-27 ◽  
Author(s):  
Taro Ichikawa ◽  
Tatsuo Kumazaki
Aorta ◽  
2020 ◽  
Vol 08 (02) ◽  
pp. 029-034
Author(s):  
Yunosuke Nishihara ◽  
Kota Mitsui ◽  
Shinya Azama ◽  
Daisuke Okamoto ◽  
Manabu Sato ◽  
...  

Abstract Objective We investigated the hemodynamic features of Type-II endoleaks after endovascular aneurysm repair (EVAR) using four-dimensional (4D) computed tomography (CT) to identify patients with aneurysm enlargement. Methods During a 13-month period (January 2017–January 2018) at our institution, we performed 4D-CT examinations in 13 patients after EVAR because of suspected Type-II endoleaks. Three patients were excluded from the study because of other endoleaks or absence of detectable endoleaks. The ramaining 10 patients were divided into two groups: enlargement group (n = 4), in which the aneurysm volume increased, and stable group (n = 6), in which the aneurysm remained stable or shrank. A CT scanner and three-dimensional workstation were used. All images were obtained using a consistent protocol (22 phase scans using the test bolus tracking method). We analyzed the hemodynamics of the endoleak cavity (EC) relative to those of the aorta and evaluated the time-enhancement curves (TECs) using measurement protocols. The strengths of correlations between these factors in the two groups were analyzed statistically. Results TECs in the enlargement group showed a more gradual curve, and the upslope, the gradient of TEC in the ascending phase and the upslope index were significantly more gradual than those in the stable group (p = 0.0247, 0.0243). The EC washout and the EC washout index were also more gradual than in the stable group's (p = 0.019, 0.019). The enhancement duration was longer in the former than in the latter (80%, p = 0.0195; 70%, p = 0.0159; 60%, p = 0.0159). The CT number in the equilibrium phase was larger in the enlargement group than in the stable group (p = 0.019). Conclusion The 4D-CT is useful for predicting aneurysm enlargement with Type-II endoleaks after EVAR.


Author(s):  
H.W. Deckman ◽  
B.F. Flannery ◽  
J.H. Dunsmuir ◽  
K.D' Amico

We have developed a new X-ray microscope which produces complete three dimensional images of samples. The microscope operates by performing X-ray tomography with unprecedented resolution. Tomography is a non-invasive imaging technique that creates maps of the internal structure of samples from measurement of the attenuation of penetrating radiation. As conventionally practiced in medical Computed Tomography (CT), radiologists produce maps of bone and tissue structure in several planar sections that reveal features with 1mm resolution and 1% contrast. Microtomography extends the capability of CT in several ways. First, the resolution which approaches one micron, is one thousand times higher than that of the medical CT. Second, our approach acquires and analyses the data in a panoramic imaging format that directly produces three-dimensional maps in a series of contiguous stacked planes. Typical maps available today consist of three hundred planar sections each containing 512x512 pixels. Finally, and perhaps of most import scientifically, microtomography using a synchrotron X-ray source, allows us to generate maps of individual element.


Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 757
Author(s):  
Maged Sultan Alhammadi ◽  
Abeer Abdulkareem Al-mashraqi ◽  
Rayid Hussain Alnami ◽  
Nawaf Mohammad Ashqar ◽  
Omar Hassan Alamir ◽  
...  

The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18–30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland–Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.


2021 ◽  
Author(s):  
Katherine A. Wolcott ◽  
Guillaume Chomicki ◽  
Yannick M. Staedler ◽  
Krystyna Wasylikowa ◽  
Mark Nesbitt ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document