Determination of the Quantity of X Rays Absorbed by the Various Tissues of the Body

1907 ◽  
Vol 12 (7) ◽  
pp. 199-202 ◽  
Author(s):  
H. Bordier
Keyword(s):  
The Body ◽  
Universitas ◽  
2009 ◽  
Vol 1 (11) ◽  
pp. 129
Author(s):  
Franklin Gavilánez

Tomography using CT scans and MRI scans is now well-known as a medical diagnostic tool which allows for detection of tumors and other abnormalities in a noninvasive way, providing very detailed images of the inside of the body using low dosage X-rays and magnetic fields. They have both also been used for determination of material defects in moderate size objects. In medical and other applications they complement conventional tomography. There are many situations where one wants to monitor the electrical conductivity of different portions of an object, for instance, to find out whether a metal object, possibly large, has invisible cracks. This kind of tomography, usually called Electrical Impedance Tomography or EIT, has also medical applications like monitoring of blood flow. While CT and MRI are related to Euclidean geometry, EIT is closely related to hyperbolic geometry. A question that has arisen in the recent past is whether there is similar "topographic" method to monitor the "health" of networks. Our objective is to explain how EIT ideas can in fact effectively be used in this context.


1969 ◽  
Vol 08 (04) ◽  
pp. 311-319 ◽  
Author(s):  
H. Daniel

SummaryA completely new technique for scanning the interior of the human body is proposed which is based on the following principle: muons from an accelerator pass through two spark chambers and are stopped in the body. The decay electrons leave the body and pass also two spark chambers. The trajectory co-ordinates read out from the spark chambers allow the determination of the point of decay with high precision. The truly three-dimensional picture obtained in this way is truly three-dimensionally displayed on a screen. Several modifications of the basic method are described, the most important ones being the simultaneous recording of the muonic X-rays (equivalent to a chemical analysis) or of the muon precession. The necessary dose is low. The most serious disadvantage is the need of a medium-energy accelerator. Quantitative figures on resolution, efficiency, and dose are given.


Author(s):  
W. Brünger

Reconstructive tomography is a new technique in diagnostic radiology for imaging cross-sectional planes of the human body /1/. A collimated beam of X-rays is scanned through a thin slice of the body and the transmitted intensity is recorded by a detector giving a linear shadow graph or projection (see fig. 1). Many of these projections at different angles are used to reconstruct the body-layer, usually with the aid of a computer. The picture element size of present tomographic scanners is approximately 1.1 mm2.Micro tomography can be realized using the very fine X-ray source generated by the focused electron beam of a scanning electron microscope (see fig. 2). The translation of the X-ray source is done by a line scan of the electron beam on a polished target surface /2/. Projections at different angles are produced by rotating the object.During the registration of a single scan the electron beam is deflected in one direction only, while both deflections are operating in the display tube.


Author(s):  
J N Chapman ◽  
W A P Nicholson

Energy dispersive x-ray microanalysis (EDX) is widely used for the quantitative determination of local composition in thin film specimens. Extraction of quantitative data is usually accomplished by relating the ratio of the number of atoms of two species A and B in the volume excited by the electron beam (nA/nB) to the corresponding ratio of detected characteristic photons (NA/NB) through the use of a k-factor. This leads to an expression of the form nA/nB = kAB NA/NB where kAB is a measure of the relative efficiency with which x-rays are generated and detected from the two species.Errors in thin film x-ray quantification can arise from uncertainties in both NA/NB and kAB. In addition to the inevitable statistical errors, particularly severe problems arise in accurately determining the former if (i) mass loss occurs during spectrum acquisition so that the composition changes as irradiation proceeds, (ii) the characteristic peak from one of the minority components of interest is overlapped by the much larger peak from a majority component, (iii) the measured ratio varies significantly with specimen thickness as a result of electron channeling, or (iv) varying absorption corrections are required due to photons generated at different points having to traverse different path lengths through specimens of irregular and unknown topography on their way to the detector.


Author(s):  
T.B. Ball ◽  
W.M. Hess

It has been demonstrated that cross sections of bundles of hair can be effectively studied using image analysis. These studies can help to elucidate morphological differences of hair from one region of the body to another. The purpose of the present investigation was to use image analysis to determine whether morphological differences could be demonstrated between male and female human Caucasian terminal scalp hair.Hair samples were taken from the back of the head from 18 caucasoid males and 13 caucasoid females (Figs. 1-2). Bundles of 50 hairs were processed for cross-sectional examination and then analyzed using Prism Image Analysis software on a Macintosh llci computer. Twenty morphological parameters of size and shape were evaluated for each hair cross-section. The size parameters evaluated were area, convex area, perimeter, convex perimeter, length, breadth, fiber length, width, equivalent diameter, and inscribed radius. The shape parameters considered were formfactor, roundness, convexity, solidity, compactness, aspect ratio, elongation, curl, and fractal dimension.


2018 ◽  
Vol 30 (3) ◽  
pp. 167-173

Red colored lipstick is the most widely used cosmetic product. Although lipstick gives a lot of social, psychological and therapeutic benefits, it may harm the consumers. Because some lipsticks contain a considerable amount of heavy metal especially lead. Lead is being used in lipstick mainly for the pigments required to obtain needed colors. Lead accumulates in the body over time and lead-containing lipstick applied several times a day, every day, combined with lead in water and other sources, could add up to significant exposure levels. Therefore, this study was aimed to determine lead content in red colored lipsticks from market. This study was laboratorybased, analytical study by using 25 lipstick samples. Red colored lipsticks were bought from Mandalay Market by random sampling procedure and they were completely coded to avoid the bias. Then, lead content in coded samples was determined by Flame AAS according to International Conference on Harmonization (ICH) guideline. Lead contents of 88% of the lipsticks samples were more than specified limit (20 ppm) of Food and Drug Administration, United States. All of them, lead content was highest in counterfeit lipsticks group. Among the tested lipstick samples, lipstick with lowest lead content was LE-RL 01 (15.74 ppm) and the lipstick with highest lead content was CF-RL 01(60.09 ppm). In conclusion, lead contents of red colored lipsticks (22 out of 25) from market samples were higher than allowable limit (20 ppm).


2017 ◽  
Vol 68 (4) ◽  
pp. 666-670 ◽  
Author(s):  
Mirela Mihon ◽  
Catalin Stelian Tuta ◽  
Alina Catrinel Ion ◽  
Dana Niculae ◽  
Vasile Lavric

The aim of this work was the development and validation of a fast analytical method to determine the residual solvents content in radiopharmaceuticals such as: 18F-Fluorodeoxyglucose (18F-FDG), 18F-Fluoroestradiol (18F-FES), 18F-Fluorothymidine (18F-FLT),18F-Fluoromisonidazole (18F-FMISO). Radiopharmaceuticals are radioactive preparations for medical purposes used in nuclear medicine as tracers in diagnostic imaging and treatment of certain diseases. Positron Emission Tomography (PET) is a medical imaging technique that consists in introducing into the body of a small amount of a biologically active chemical compound labelled with a short lived positron-emitting radioisotope (18F, 11C, 68Ga). Residual solvents are critical impurities in radiopharmaceuticals that can affect labelling, stability and physicochemical properties of drugs. Therefore, the determination of these solvents is essential for quality control of radiopharmaceuticals. Validation of the control method for residual solvents by gas chromatography is referred by the European Pharmacopoeia using a special injection technique (head space). The parameters of the method, which comply with International Conference on Harmonization guidelines, are: accuracy, precision, linearity, limit of detection, limit of quantification and robustness. The proposed method (direct gas chromatography injection) proved to be linear, precise, accurate and robust. Good linearity was achieved for all the solvents and correlation coefficients (R2) for each residual solvent were found more than 0.99.


2021 ◽  
Vol 11 (15) ◽  
pp. 6948
Author(s):  
Gabriele Cervino ◽  
Sergio Sambataro ◽  
Chiara Stumpo ◽  
Salvatore Bocchieri ◽  
Fausto Murabito ◽  
...  

The aim of this study is to demonstrate the use and the effectiveness of cephalometry and golden proportions analysis of the face in planning prosthetic treatments in totally edentulous patients. In order to apply this method, latero-lateral and posterior-anterior X-rays must be performed in addition to the common procedure. Two main concerns for totally edentulous patients are the establishment of the vertical dimension and the new position of the occlusal plane. The divine proportion analysis was carried out by the use of a golden divider. The prosthetic protocol was divided into three steps and a case was selected for better understanding. Referring to the golden relations, if the distance from the chin to the wing of the nose is 1.0, the distance from the nose to eye is 0.618. This proportion is useful and effective in determining the correct prosthetic vertical dimension. The incisal margin of the lower incisor must be positioned between Point A (A) and protuberance menti (Pm) according to the gold ratio 0.618 of the total height A-Pm. Posteriorly the occlusal plane must be placed 2 mm below the divine occlusal plane (traced from the incisal margin of lower incisors to Xi point). A prosthesis made in accordance with cephalometric parameters and divine proportions of the face helps to improve the patient’s aesthetics, function and social personality.


1920 ◽  
Vol 44 (2) ◽  
pp. 211-213
Author(s):  
W. Prentice ◽  
H.O. Lund ◽  
H.G. Harbo

Sign in / Sign up

Export Citation Format

Share Document