Application of TLC and Plasma-Based Ambient MS in Bioanalytical Sciences

Author(s):  
Marek Smoluch ◽  
Przemysław Mielczarek ◽  
Michał Cegłowski ◽  
Grzegorz Schroeder ◽  
Jerzy Silberring
Keyword(s):  
Micromachines ◽  
2018 ◽  
Vol 9 (12) ◽  
pp. 649 ◽  
Author(s):  
Gowtham Sathyanarayanan ◽  
Markus Haapala ◽  
Tiina Sikanen

This work describes the interfacing of electrowetting-on-dielectric based digital microfluidic (DMF) sample preparation devices with ambient mass spectrometry (MS) via desorption atmospheric pressure photoionization (DAPPI). The DMF droplet manipulation technique was adopted to facilitate drug distribution and metabolism assays in droplet scale, while ambient mass spectrometry (MS) was exploited for the analysis of dried samples directly on the surface of the DMF device. Although ambient MS is well-established for bio- and forensic analyses directly on surfaces, its interfacing with DMF is scarce and requires careful optimization of the surface-sensitive processes, such as sample precipitation and the subsequent desorption/ionization. These technical challenges were addressed and resolved in this study by making use of the high mechanical, thermal, and chemical stability of SU-8. In our assay design, SU-8 served as the dielectric layer for DMF as well as the substrate material for DAPPI-MS. The feasibility of SU-8 based DMF devices for DAPPI-MS was demonstrated in the analysis of selected pharmaceuticals following on-chip liquid-liquid extraction or an enzymatic dealkylation reaction. The lower limits of detection were in the range of 1–10 pmol per droplet (0.25–1.0 µg/mL) for all pharmaceuticals tested.


2018 ◽  
Vol 2018 ◽  
pp. 1-18 ◽  
Author(s):  
Andreas Kiontke ◽  
Susan Billig ◽  
Claudia Birkemeyer

Modern technical evolution made mass spectrometry (MS) an absolute must for analytical chemistry in terms of application range, detection limits and speed. When it comes to mass spectrometric detection, one of the critical steps is to ionize the analyte and bring it into the gas phase. Several ionization techniques were developed for this purpose among which electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) are two of the most frequently applied atmospheric pressure methods to ionize target compounds from liquid matrices or solutions. Moreover, recent efforts in the emerging field of “ambient” MS enable the applicability of newly developed atmospheric pressure techniques to solid matrices, greatly simplifying the analysis of samples with MS and anticipating, to ease the required or even leave out any sample preparation and enable analysis at ambient conditions, outside the instrument itself. These developments greatly extend the range of applications of modern mass spectrometry (MS). Ambient methods comprise many techniques; a particular prominent group is, however, the plasma-based methods. Although ambient MS is a rather new field of research, the interest in further developing the corresponding techniques and enhancing their performance is very strong due to their simplicity and often low cost of manufacturing. A precondition for improving the performance of such ion sources is a profound understanding how ionization works and which parameters determine signal response. Therefore, we review relevant compound characteristics for ionization with the two traditional methods ESI and APCI and compare those with one of the most frequently employed representatives of the plasma-based methods, i.e., low temperature plasma ionization. We present a detailed analysis in which compound characteristics are most beneficial for the response of aromatic nitrogen-containing compounds with these three methods and provide evidence that desorption characteristics appear to have the main common, general impact on signal response. In conclusion, our report provides a very useful resource to the optimization of instrumental conditions with respect to most important requirements of the three ionization techniques and, at the same time, for future developments in the field of ambient ionization.


The Analyst ◽  
2015 ◽  
Vol 140 (8) ◽  
pp. 2599-2602 ◽  
Author(s):  
Yaoyao Zhao ◽  
Xiaoyun Gong ◽  
Xingyu Si ◽  
Zhenwei Wei ◽  
Chengdui Yang ◽  
...  

A simple method of excellent selectivity and sensitivity for enrichment of phosphopeptides in complex biological samples.


2016 ◽  
Vol 62 (1) ◽  
pp. 99-110 ◽  
Author(s):  
Christina R Ferreira ◽  
Karen E Yannell ◽  
Alan K Jarmusch ◽  
Valentina Pirro ◽  
Zheng Ouyang ◽  
...  

Abstract BACKGROUND One driving motivation in the development of point-of-care (POC) diagnostics is to conveniently and immediately provide information upon which healthcare decisions can be based, while the patient is on site. Ambient ionization mass spectrometry (MS) allows direct chemical analysis of unmodified and complex biological samples. This suite of ionization techniques was introduced a decade ago and now includes a number of techniques, all seeking to minimize or eliminate sample preparation. Such approaches provide new opportunities for POC diagnostics and rapid measurements of exogenous and endogenous molecules (e.g., drugs, proteins, hormones) in small volumes of biological samples, especially when coupled with miniature mass spectrometers. CONTENT Ambient MS-based techniques are applied in diverse fields such as forensics, pharmaceutical development, reaction monitoring, and food analysis. Clinical applications of ambient MS are at an early stage but show promise for POC diagnostics. This review provides a brief overview of various ambient ionization techniques providing background, examples of applications, and the current state of translation to clinical practice. The primary focus is on paper spray (PS) ionization, which allows quantification of analytes in complex biofluids. Current developments in the miniaturization of mass spectrometers are discussed. SUMMARY Ambient ionization MS is an emerging technology in analytical and clinical chemistry. With appropriate MS instrumentation and user-friendly interfaces for automated analysis, ambient ionization techniques can provide quantitative POC measurements. Most significantly, the implementation of PS could improve the quality and lower the cost of POC testing in a variety of clinical settings.