A new formula of phase contrast imaging for continuous X-ray based on in-line X-ray imaging

2021 ◽  
Vol 11 (7) ◽  
pp. 2971
Author(s):  
Siwei Tao ◽  
Congxiao He ◽  
Xiang Hao ◽  
Cuifang Kuang ◽  
Xu Liu

Numerous advances have been made in X-ray technology in recent years. X-ray imaging plays an important role in the nondestructive exploration of the internal structures of objects. However, the contrast of X-ray absorption images remains low, especially for materials with low atomic numbers, such as biological samples. X-ray phase-contrast images have an intrinsically higher contrast than absorption images. In this review, the principles, milestones, and recent progress of X-ray phase-contrast imaging methods are demonstrated. In addition, prospective applications are presented.


2015 ◽  
Vol 22 (6) ◽  
pp. 1531-1539 ◽  
Author(s):  
A. K. Agrawal ◽  
B. Singh ◽  
Y. S. Kashyap ◽  
M. Shukla ◽  
P. S. Sarkar ◽  
...  

A full-field hard X-ray imaging beamline (BL-4) was designed, developed, installed and commissioned recently at the Indus-2 synchrotron radiation source at RRCAT, Indore, India. The bending-magnet beamline is operated in monochromatic and white beam mode. A variety of imaging techniques are implemented such as high-resolution radiography, propagation- and analyzer-based phase contrast imaging, real-time imaging, absorption and phase contrast tomographyetc. First experiments on propagation-based phase contrast imaging and micro-tomography are reported.


Author(s):  
Farid H. Omoumi ◽  
Muhammad U. Ghani ◽  
Molly D. Wong ◽  
Yuchen Qiu ◽  
Yuhua Li ◽  
...  

2008 ◽  
Vol 2008 ◽  
pp. 1-8 ◽  
Author(s):  
Ming Jiang ◽  
Christopher Lee Wyatt ◽  
Ge Wang

X-ray imaging is of paramount importance for clinical and preclinical imaging but it is fundamentally restricted by the attenuation-based contrast mechanism, which has remained essentially the same since Roentgen's discovery a century ago. Recently, based on the Talbot effect, groundbreaking work was reported using 1D gratings for X-ray phase-contrast imaging with a hospital-grade X-ray tube instead of a synchrotron or microfocused source. In this paper, we report an extension using 2D gratings that reduces the imaging time and increases the accuracy and robustness of phase retrieval compared to current grating-based phase-contrast techniques. Feasibility is demonstrated via numerical simulation.


2020 ◽  
Vol 27 (2) ◽  
pp. 462-467
Author(s):  
T. S. Argunova ◽  
V. G. Kohn ◽  
J.-H. Lim ◽  
Z. V. Gudkina ◽  
E. D. Nazarova

An investigation of the problems of X-ray imaging of dentinal tubules is presented. Two main points are addressed. In the first part of this paper, the problem of computer simulating tubule images recorded in a coherent synchrotron radiation (SR) beam has been discussed. A phantom material which involved a two-dimensional lattice of the tubules with parameters similar to those of dentin was considered. By a comparative examination of two approximations, it was found that the method of phase-contrast imaging is valid if the number of tubules along the beam is less than 100. Calculated images from a lattice of 50 × 50 tubules are periodic in free space but depend strongly on the distance between the specimen and the detector. In the second part, SR microtomographic experiments with millimetre-sized dentin samples in a partially coherent beam have been described. Tomograms were reconstructed from experimental projections using a technique for incoherent radiation. The main result of this part is the three-dimensional rendering of the directions of the tubules in a volume of the samples. Generation of the directions is possible because a tomogram shows the positions of the tubules. However, a detailed tubule cross-section structure cannot be restored.


Author(s):  
Alessandro Olivo ◽  
Ian Robinson

A double event, supported as part of the Royal Society scientific meetings, was organized in February 2013 in London and at Chicheley Hall in Buckinghamshire by Dr A. Olivo and Prof. I. Robinson. The theme that joined the two events was the use of X-ray phase in novel imaging approaches, as opposed to conventional methods based on X-ray attenuation. The event in London, led by Olivo, addressed the main roadblocks that X-ray phase contrast imaging (XPCI) is encountering in terms of commercial translation, for clinical and industrial applications. The main driver behind this is the development of new approaches that enable XPCI, traditionally a synchrotron method, to be performed with conventional laboratory sources, thus opening the way to its deployment in clinics and industrial settings. The satellite meeting at Chicheley Hall, led by Robinson, focused on the new scientific developments that have recently emerged at specialized facilities such as third-generation synchrotrons and free-electron lasers, which enable the direct measurement of the phase shift induced by a sample from intensity measurements, typically in the far field. The two events were therefore highly complementary, in terms of covering both the more applied/translational and the blue-sky aspects of the use of phase in X-ray research. optics, image processing


2020 ◽  
Vol 64 (2) ◽  
pp. 20503-1-20503-5
Author(s):  
Faiz Wali ◽  
Shenghao Wang ◽  
Ji Li ◽  
Jianheng Huang ◽  
Yaohu Lei ◽  
...  

Abstract Grating-based x-ray phase-contrast imaging has the potential to enhance image quality and provide inner structure details non-destructively. In this work, using grating-based x-ray phase-contrast imaging system and employing integrating-bucket method, the quantitative expressions of signal-to-noise ratios due to photon statistics and mechanical error are analyzed in detail. Photon statistical noise and mechanical error are the main sources affecting the image noise in x-ray grating interferometry. Integrating-bucket method is a new phase extraction method translated to x-ray grating interferometry; hence, its image quality analysis would be of great importance to get high-quality phase image. The authors’ conclusions provide an alternate method to get high-quality refraction signal using grating interferometer, and hence increases applicability of grating interferometry in preclinical and clinical usage.


Sign in / Sign up

Export Citation Format

Share Document