Roof Isolation System to Reduce the Seismic Response of Buildings: A Preliminary Assessment

1998 ◽  
Vol 14 (3) ◽  
pp. 521-532 ◽  
Author(s):  
Roberto Villaverde

A roof isolation system is proposed as a means to reduce the detrimental effect of earthquakes in buildings. This roof isolation system entails the insertion of flexible laminated rubber bearings between a building's roof and the columns that support it, and the addition of viscous dampers connected between the roof and the rest of the building. The properties and dimensions of the rubber bearings and viscous dampers are selected in a way that makes the roof, bearings, and dampers form a highly damped vibration absorber. Presented also is a comparative study with a simple five-story steel building under a strong earthquake ground motion that is carried out to assess the effectiveness of the proposed system. In this comparative study, it is found that the roof isolation scheme reduces the floor displacements and interstory drifts of the analyzed building by as much as 83 percent. On the basis of these results and in view of its simplicity, it is concluded that the proposed roof isolation system has the potential to become a practical and effective way to reduce earthquake damage in buildings.

2010 ◽  
Vol 10 (02) ◽  
pp. 287-298 ◽  
Author(s):  
J. S. HWANG ◽  
C. F. HUNG ◽  
Y. N. HUANG ◽  
S. J. WANG

In seismic isolation design of structures located at soft soil sites or near field areas, viscous dampers (VD) are often included as part of the isolation system to minimize its maximum displacement. Due to the 90° phase angle existing between the force and displacement of the VD, the maximum force transmitted by the isolation system cannot be calculated by simply combining the forces of the isolation bearings, such as lead-rubber bearings (LRB) or high damping rubber bearings (HDRB), and VD in association with the design displacement. Conforming to the code-specified equivalent lateral response procedure for isolation design, this paper presents a formula for determining the seismic design force of the combined LRB and VD isolation system, taking into account the phase angle between the combined force of the LRB and VD and the displacement of the isolation system. The numerical results have shown that the maximum responses of the isolation system predicted by the proposed formula are conservative and comparable with those from the inelastic dynamic response history analysis.


2012 ◽  
Vol 234 ◽  
pp. 96-101 ◽  
Author(s):  
Donato Cancellara ◽  
Fabio de Angelis

In the present work we have analyzed a particular base isolation system for the seismic protection of a multi-storey reinforced concrete (RC) building. The viscous dampers and friction sliders are the devices adopted in parallel for realizing the base isolation system. The base isolation structure has been designed and verified according to European seismic code EC8 and by considering for the friction sliders the influence of the sliding velocity on the value of the friction coefficient. A dynamic nonlinear analysis for a three-dimensional base isolated structure has been performed. Recorded accelerograms for bi-directional ground motions have been used which comply with the requirements imposed by EC8 for the representation of a seismic action in a time history analysis. In this paper a comparative analysis is presented between the base isolated structure with the described hybrid base isolation system and the traditional fixed base structure.


2014 ◽  
Vol 580-583 ◽  
pp. 1633-1636 ◽  
Author(s):  
Sen Qiu ◽  
Shu Cheng Deng ◽  
Zhao Quan Zhu

This article focuses on the effect of viscous damper on seismic performance of steel-concrete hybrid structure under strong earthquake. The result shows that viscous damper has effect on seismic reduction and control. The story lateral displacement, story drift rotation and energy dissipation-seismic can be reduced effectively by viscous dampers. The maximum value of vibration-reduction ratio is 36.0%, 67.9%, 36.9%. It is different effect on seismic reduction by different earthquake ground motion. Response of earthquake amplifies under Pasadena earthquake wave than the others.


2020 ◽  
Vol 36 (4) ◽  
pp. 1886-1911 ◽  
Author(s):  
Anastasios Tsiavos ◽  
Anastasios Sextos ◽  
Andreas Stavridis ◽  
Matt Dietz ◽  
Luiza Dihoru ◽  
...  

This study presents a large-scale experimental investigation on the seismic performance of an innovative, low-cost seismic isolation system for developing countries. It is based on the beneficial effect of the encapsulation of sand grains between two PVC surfaces on the initiation of sliding and the dissipation of seismic energy between the surfaces. A three-times scaled-down, idealized, seismically isolated model of a prototype single-story structure located in Nepal is subjected to an ensemble of recorded earthquake ground motion excitations. The experimentally derived response of the seismically isolated structure is compared with the response of the corresponding fixed-base structure. This system is part of a wider hybrid design approach where the structure is designed to resist the seismic forces at the design acceleration level. The seismic isolation system sets an upper bound to the response of the structure for ground motion excitations exceeding the design level.


2001 ◽  
Vol 7 (12) ◽  
pp. 99-104 ◽  
Author(s):  
Ichizo KAWABATA ◽  
Masaharu TAKAYAMA ◽  
Yasuhiro NISHIKAWA ◽  
Yuichi KIMURA ◽  
Eiichi YAMAZAKI ◽  
...  

2011 ◽  
Vol 255-260 ◽  
pp. 1225-1229
Author(s):  
Huang Sheng Sun ◽  
Li Nuo Cheng ◽  
Shi Hai Chen

In order to mitigate the seismic response of twin-tower structure linked by a steel truss platform bridge, as well as to reduce temperature force in the steel truss, eight groups of combined isolation system, each consisting of one pot-type bearing and four rubber bearings, were designed to connect the upper platform bridge to the lower supporting reinforced concrete towers. The features and working principles of the high-position isolation system were described. Then the seismic responses, including displacement, story drift and floor acceleration, of the structure with the isolation systems were calculated and compared with those of the structure with hinge joints in lieu of isolation. It is found that both the structural seismic responses and the temperature forces in the large-span mega-truss structure can be reduced by the high-position isolation system.


Sign in / Sign up

Export Citation Format

Share Document