Performance of Structures with Passive Energy Dissipators

2002 ◽  
Vol 18 (1) ◽  
pp. 105-119 ◽  
Author(s):  
H. Kit Miyamoto ◽  
J. P. Singh

The purpose of this paper is to evaluate the earthquake performance of structures with passive energy dissipators. This paper addresses the following issues: (1) evaluation of seismic intensity levels at which frames incorporating the energy dissipating system (EDS) remain elastic; (2) performance evaluation of frames incorporating an EDS for high-intensity ground shaking; and (3) evaluation of SEAOC Blue Book provisions. Linear time-history analyses indicate that frames with an EDS generally remain elastic during earthquake events that do not greatly exceed the UBC Zone 4 response spectrum. Nonlinear time-history analyses indicate the following: (1) the frames with an EDS can provide “immediate occupancy performance” for high-intensity earthquakes; (2) the performance level of the frames with an EDS exceeds that of frames without an EDS; and (3) the performance of the frame with an EDS, which was designed per Blue Book provisions, can exceed life safety performance.

2000 ◽  
Vol 16 (2) ◽  
pp. 367-391 ◽  
Author(s):  
Balram Gupta ◽  
Sashi K. Kunnath

The estimation of inelastic seismic demands using nonlinear static procedures, or pushover analyses, are inevitably going to be favored by practicing engineers over nonlinear time-history methods. While there has been some concern over the reliability of static procedures to predict inelastic seismic demands, improved procedures overcoming these drawbacks are still forthcoming. In this paper, the potential limitations of static procedures, such as those recommended in FEMA 273, are highlighted through an evaluation of the response of instrumented buildings that experienced strong ground shaking in the 1994 Northridge earthquake. A new enhanced adaptive “modal” site-specific spectra-based pushover analysis is proposed, which accounts for the effect of higher modes and overcomes the shortcomings of the FEMA procedure. Features of the proposed procedure include its similarity to traditional response spectrum-based analysis and the explicit consideration of ground motion characteristics during the analysis. It is demonstrated that the proposed procedure is able to reasonably capture important response attributes, such as interstory drift and failure mechanisms, even for structures with discontinuities in strength and/or stiffness that only a detailed nonlinear dynamic analysis could predict.


2021 ◽  
pp. 107754632110075
Author(s):  
Junling Chen ◽  
Jinwei Li ◽  
Dawei Wang ◽  
Youquan Feng

The steel–concrete hybrid wind turbine tower is characterized by the concrete tubular segment at the lower part and the traditional steel tubular segment at the upper part. Because of the great change of mass and stiffness along the height of the tower at the connection of steel segment and concrete segment, its dynamic responses under seismic ground motions are significantly different from those of the traditional steel tubular wind turbine tower. Two detailed finite element models of a full steel tubular tower and a steel–concrete hybrid tower for 2.0 MW wind turbine built in the same wind farm are, respectively, developed by using the finite element software ABAQUS. The response spectrum method is applied to analyze the seismic action effects of these two towers under three different ground types. Three groups of ground motions corresponding to three ground types are used to analyze the dynamic response of the steel–concrete hybrid tower by the nonlinear time history method. The numerical results show that the seismic action effect by the response spectrum method is lower than those by the nonlinear time history method. And then it can be concluded that the response spectrum method is not suitable for calculating the seismic action effects of the steel–concrete hybrid tower directly and the time history analyses should be a necessary supplement for its seismic design. The first three modes have obvious contributions on the dynamic response of the steel–concrete hybrid tower.


2015 ◽  
Vol 724 ◽  
pp. 353-357
Author(s):  
Jian Zhu ◽  
Ping Tan ◽  
Pei Ju Chang

This study focus on derivation of such vulnerability curves using Fiber Reinforced Polymers technologies retrofitted conventional RC industrial frames with masonry infill wall. A set of stochastic earthquake waves which compatible with the response spectrum of China seismic code are created. Dynamic time history analysis is used to compute the random sample of structures. Stochastic damage scatter diagrams based different seismic intensity index are obtained. Seismic vulnerability of FRP-reinforced RC industrial frames is lower than unreinforced frames obviously, and seismic capability of frames using FRP technologies is enhanced especially under major earthquake.


2013 ◽  
Vol 788 ◽  
pp. 558-561
Author(s):  
Jian Qiang Wang ◽  
Wen Tao Ma ◽  
Min Jing Ma

Steel reinforced concrete composite structure which apply in the high-rise buildings, not only save steel, but also have excellent properties in fire prevention, anti-corrosion, and seismic performance, and improve the speed of construction, economic efficiency.This thesis based on the analyse of a steel reinforced concrete composite structure tower and the domestic and foreign experts study use Finite Element Analysis software SAP2000 analyze the dynamic Performance of the structure to draw the inherent vibration period and frequency of the structure. The structure is analyzed to obtain its deformation with different height of the structural elements under a small earthquake. Structure and component in elastic stage when suffur a small earthquake. Using the mode decomposition response spectrum method and method of linear time history analysis, the maximum horizontal displacements of the structural layer, the maximum inter-story displacement and the maximum inter-story displacement angle is obtained to see if the results within a predetermined range.


2015 ◽  
Vol 744-746 ◽  
pp. 890-893
Author(s):  
Xun Wu ◽  
Yong Lan Zhang

In this paper, SAP2000 and ANSYS software are used to modeling and analysis athree-span continuous beam bridge with high piers case study.By using differentbearing types and combinations to form different options, create two finiteelement models.Analysis dynamic characteristics ,elastic response spectra,linear time history and nonlinear time history .And focus on comparing dynamiccharacteristics of the earthquake response of the two programs .Running outputdata processing and comparison results show that the application of thedifferent parameters of the rational combination of rubber bearing basin bridgearrangement has better seismic performance.


2019 ◽  
Vol 13 (03n04) ◽  
pp. 1940003 ◽  
Author(s):  
Xiaoyan Yang ◽  
Jing Wu ◽  
Jian Zhang ◽  
Yulong Feng

A novel structural wall with hinge support and buckling restrained braces (BRBs) set in the base (HWBB) is studied. HWBB can be applied to precast manufacturing due to its considerable ductility and the separate loading mechanism in HWBB–frame structure. In elastic stage, BRBs play a brace role to make the hinged wall resist horizontal forces like a shear wall. BRBs dissipate seismic energy through plastic and hysteresis effects after yielding and the damage is only concentrated in BRBs. The performance of an HWBB is equivalent to a shear wall structure with excellent ductility and stable energy dissipation capacity. Numerical analysis indicates that the hinged wall body in the HWBB well controls the deformation mode of the structure, avoiding the concentration of story drifts, thereby protecting the remaining parts of the structure. It is revealed that the moments of the wall body will generate significant increments after BRBs yielding, and the Seismic Intensity Superposition Method is proposed to calculate the moments. In this method, nonlinear response of an HWBB can be regarded as the sum of the responses of two elastic corresponding structures excited with two parts of the seismic intensity, respectively. Modes and moments equations of the hinged wall with uniform distribution of stiffness and mass are derived, and calculation results coincide with that of the nonlinear time history analysis (NHA). For a more general case, the white noise scan method is proposed to solve the structure’s natural characteristics and to further calculate the response. Finally, the post-yielding moment calculation method and the process based on design response spectrum are proposed. It is proved that the moments from proposed Seismic Intensity Superposition Method can envelop most of the moments from NHA, and it is a good estimate of the response of HWBB in nonlinear stage.


2009 ◽  
Vol 25 (3) ◽  
pp. 583-605 ◽  
Author(s):  
Wei Chiang Pang ◽  
David V. Rosowsky

This paper presents a direct displacement design (DDD) procedure that can be used for seismic design of multistory wood-framed structures. The proposed procedure is applicable to any pure shear deforming system. The design procedure is a promising design tool for performance-based seismic design since it allows consideration of multiple performance objectives (e.g., damage limitation, safety requirements) without requiring the engineer to perform a complex finite element or nonlinear time-history analysis of the complete structure. A simple procedure based on normalized modal analysis is used to convert the code-specified acceleration response spectrum into a set of interstory drift spectra. These spectra can be used to determine the minimum stiffness required for each floor based on the drift limit requirements. Specific shear walls can then be directly selected from a database of backbone curves. The procedure is illustrated on the design of two three-story ATC-63 archetype buildings, and the results are validated using nonlinear time-history analysis.


2017 ◽  
Vol 44 (8) ◽  
pp. 661-673 ◽  
Author(s):  
J. Beauchamp ◽  
P. Paultre ◽  
P. Léger

This paper presents a simple method based on modal response spectrum analysis to compute internal forces in structural elements belonging to gravity framing not part of the seismic force resisting system (SFRS). It is required that demands on these gravity load resisting system (GLRS) be determined according to the design displacement profile of the SFRS. The proposed new method uses the fact that if the linear stiffness properties of the GLRS not part of the SFRS have negligible values compared to those of the SFRS, only the latter will provide lateral resistance. Displacements of the GLRS then correspond to those of the SFRS alone. The new method is illustrated by computing the seismic responses of a symmetric and an asymmetric multi-storey reinforced concrete building. These results are compared to those obtained from the application of the simplified analysis method proposed in the Canadian standard for the design of concrete structures. Nonlinear time history analyses are also performed to provide a benchmark for comparison. Results show that the new method can predict shear and bending moment in all members at once with ease. Therefore, this new simplified method can effectively be used to predict seismic forces in elements not considered part of the SFRS.


2013 ◽  
Vol 739 ◽  
pp. 309-313 ◽  
Author(s):  
Pei Ju Chang

This study focus on derivation of such fragility curves using classic mid-story isolation and reduction structures (MIRS) in China metropolis. This study focus on derivation of such fragility curves using conventional industrial frames with masonry infill wall. A set of stochastic earthquake waves compatible with the response spectrum of China seismic code selected to represent the variability in ground motion. Dynamic inelastic time history analysis was used to analyze the random sample of structures. MIRS seismic capability of longitudinal and transversal orientation is different. Stochastic damage scatter diagrams based different seismic intensity index are obtained. Seismic fragility of longitudinal axis (Y axis) is larger than transversal axis (X axis) of frames under major earthquake obviously.


Base isolation is an effective way to protect large structures from earthquake damage. It is a costly approach, as the entire structure must be supported on elastomeric or sliding bearings. Viscous dampers distributed throughout an otherwise conventional structure can achieve the same result at a significantly lower cost. Dampers are used to resist lateral forces coming on the structure. Dampers are the energy dissipating devices which also resist displacement of Reinforced Concrete (RC) buildings during an earthquake. These dampers help the structure to reduce buckling of columns thereby increasing the stiffness of the structure. During earthquakes, multi-storeyed buildings get damaged and as a result, large deformation occurs. Dampers reduce vibration and deformation of structural elements during an earthquake. Retrofitting buildings with fluid viscous dampers (FVDs) can improve Interstorey drifts and floor accelerations. In the present study, an RC framed building is modelled and analysed under Southern Sumatra and Chile earthquakes to evaluate the performance of the structure and its elements with and without energy dissipators. For the study, a model (G+19) with and without energy dissipators is modelled in ETABS. The seismic force is applied based on the time history data of the models pertaining to Southern Sumatra and Chile Earthquake. Response Spectrum analysis has been carried out to find the lateral displacements, storey shear and Base shear for the model with and without dampers. The lateral displacement, storey drift, storey shear and Base shear are found to less for the model with Linear FVDs when compared to the model with Non-Linear FVDs and without FVDs.


Sign in / Sign up

Export Citation Format

Share Document