scholarly journals Clinical Assessment of Electromagnetic Compatibility of Hearing Aids and Digital Wireless Phones

Author(s):  
Robert E. Schlegel ◽  
Shalini Srinivasan ◽  
Hank Grant ◽  
Randa L. Shehab ◽  
Shivakumar Raman

Research studies have shown that digital wireless phones interact with some hearing aids, creating a buzzing noise that may reduce speech intelligibility. Interference signals for three phone technologies were generated at five sound pressure levels (35 dB, 45 dB, 55 dB, 65 dB, and 75 dB) and mixed with speech at 65 dB SPL to test the speech intelligibility of 24 hearing-impaired people. A “No Noise” condition was also tested. Scores for the TDMA-217 Hz phone signal at low speech-to-noise ratios (<10 dB) were significantly lower than those for CDMA and TDMA-50 Hz at the same level. The CDMA and TDMA-50 Hz phone signals had a similar effect on speech intelligibility. Speech intelligibility scores at speech-to-noise ratios of 20 dB and 30 dB were similar to those for the “No Noise” condition. The articulation index represented the best index for predicting the impact of wireless phone interference on speech intelligibility.

2020 ◽  
pp. 1351010X2092358
Author(s):  
Zakariyya Uzeyirli ◽  
Aslı Özçevik Bilen

The inclusive education method has substantial contributions to hearing-impaired individuals’ education and socialization. However, the poor physical environment and acoustic comfort conditions negatively affect speech intelligibility at such places and therefore, the quality of education. Upon determining that there are very few subjective evaluation studies, we conducted a study regarding the impact of acoustic comfort conditions on speech intelligibility at inclusive education places. Within the scope of the study, first, a classroom was determined, and the current acoustic conditions of the class were evaluated objectively by field acoustic measurements. A calibrated model was created in the simulation software of the relevant class and then two more models with optimum reverberation time values of 0.4 s and 0.8 s as suggested in the literature, and auralizations were performed for the models. For subjective evaluation, a subject group of hearing-impaired and normal hearing individuals fulfilling equal conditions were tested by speech discrimination test in real-time in the classroom and from auralization recordings in a laboratory setting. Regarding the results obtained, it was observed that speech intelligibility percentage of normal hearing individuals increased as expected while in hearing-impaired individuals, contrary to the expectations, percentage differed from one another, and there was no increase. Following the discussions with experts, it was concluded that different hearing aids used by hearing-impaired individuals might lead to this situation. Accordingly, it occurs that the possibility to achieve a good speech intelligibility for hearing-impaired individuals even if optimum acoustic values suggested are fulfilled in education places remains unclear.


2015 ◽  
Vol 26 (03) ◽  
pp. 260-274 ◽  
Author(s):  
Teresa Y.C. Ching ◽  
Tian Kar Quar ◽  
Earl E. Johnson ◽  
Philip Newall ◽  
Mridula Sharma

Background: An important goal of providing amplification to children with hearing loss is to ensure that hearing aids are adjusted to match targets of prescriptive procedures as closely as possible. The Desired Sensation Level (DSL) v5 and the National Acoustic Laboratories’ prescription for nonlinear hearing aids, version 1 (NAL-NL1) procedures are widely used in fitting hearing aids to children. Little is known about hearing aid fitting outcomes for children with severe or profound hearing loss. Purpose: The purpose of this study was to investigate the prescribed and measured gain of hearing aids fit according to the NAL-NL1 and the DSL v5 procedure for children with moderately severe to profound hearing loss; and to examine the impact of choice of prescription on predicted speech intelligibility and loudness. Research Design: Participants were fit with Phonak Naida V SP hearing aids according to the NAL-NL1 and DSL v5 procedures. The Speech Intelligibility Index (SII) and estimated loudness were calculated using published models. Study Sample: The sample consisted of 16 children (30 ears) aged between 7 and 17 yr old. Data Collection and Analysis: The measured hearing aid gains were compared with the prescribed gains at 50 (low), 65 (medium), and 80 dB SPL (high) input levels. The goodness of fit-to-targets was quantified by calculating the average root-mean-square (RMS) error of the measured gain compared with prescriptive gain targets for 0.5, 1, 2, and 4 kHz. The significance of difference between prescriptions for hearing aid gains, SII, and loudness was examined by performing analyses of variance. Correlation analyses were used to examine the relationship between measures. Results: The DSL v5 prescribed significantly higher overall gain than the NAL-NL1 procedure for the same audiograms. For low and medium input levels, the hearing aids of all children fit with NAL-NL1 were within 5 dB RMS of prescribed targets, but 33% (10 ears) deviated from the DSL v5 targets by more than 5 dB RMS on average. For high input level, the hearing aid fittings of 60% and 43% of ears deviated by more than 5 dB RMS from targets of NAL-NL1 and DSL v5, respectively. Greater deviations from targets were associated with more severe hearing loss. On average, the SII was higher for DSL v5 than for NAL-NL1 at low input level. No significant difference in SII was found between prescriptions at medium or high input level, despite greater loudness for DSL v5 than for NAL-NL1. Conclusions: Although targets between 0.25 and 2 kHz were well matched for both prescriptions in commercial hearing aids, gain targets at 4 kHz were matched for NAL-NL1 only. Although the two prescriptions differ markedly in estimated loudness, they resulted in comparable predicted speech intelligibility for medium and high input levels.


2013 ◽  
Vol 24 (02) ◽  
pp. 105-120 ◽  
Author(s):  
Ann E. Perreau ◽  
Ruth A. Bentler ◽  
Richard S. Tyler

Background: Frequency-lowering signal processing in hearing aids has re-emerged as an option to improve audibility of the high frequencies by expanding the input bandwidth. Few studies have investigated the usefulness of the scheme as an option for bimodal users (i.e., combined use of a cochlear implant and a contralateral hearing aid). In this study, that question was posed. Purpose: The purposes of this study were (1) to determine if frequency compression was a better bimodal option than conventional amplification and (2) to determine the impact of a frequency-compression hearing aid on speech recognition abilities. Research Design: There were two separate experiments in this study. The first experiment investigated the contribution of a frequency-compression hearing aid to contralateral cochlear implant (CI) performance for localization and speech perception in noise. The second experiment assessed monaural consonant and vowel perception in quiet using the frequency-compression and conventional hearing aid without the use of a contralateral CI or hearing aid. Study Sample: Ten subjects fitted with a cochlear implant and hearing aid participated in the first experiment. Seventeen adult subjects with a cochlear implant and hearing aid or two hearing aids participated in the second experiment. To be included, subjects had to have a history of postlingual deafness, a moderate or moderate-to-severe hearing loss, and have not worn this type of frequency-lowering hearing aid previously. Data Collection and Analysis: In the first experiment, performance using the frequency-compression and conventional hearing aids was assessed on tests of sound localization, speech perception in a background of noise, and two self-report questionnaires. In the second experiment, consonant and vowel perception in quiet was assessed monaurally for the two conditions. In both experiments, subjects alternated daily between a frequency-compression and conventional hearing aid for 2 mo. The parameters of frequency compression were set individually for each subject, and audibility was measured for the frequency compression and conventional hearing aid programs by comparing estimations of the Speech Intelligibility Index (SII) using a modified algorithm (Bentler et al, 2011). In both experiments, the outcome measures were administered following the hearing aid fitting to assess performance at baseline and after 2 mo of use. Results: For this group of subjects, the results revealed no significant difference between the frequency-compression and conventional hearing aid on tests of localization and consonant recognition. Spondee-in-noise and vowel perception scores were significantly higher with the conventional hearing aid compared to the frequency-compression hearing aid after 2 mo of use. Conclusions: These results suggest that, for the subjects in this study, frequency compression is not a better bimodal option than conventional amplification. In addition, speech perception may be negatively influenced by frequency compression because formant frequencies are too severely compressed and can no longer be distinguished.


1996 ◽  
Vol 5 (1) ◽  
pp. 23-32 ◽  
Author(s):  
Chris Halpin ◽  
Barbara Herrmann ◽  
Margaret Whearty

The family described in this article provides an unusual opportunity to relate findings from genetic, histological, electrophysiological, psychophysical, and rehabilitative investigation. Although the total number evaluated is large (49), the known, living affected population is smaller (14), and these are spread from age 20 to age 59. As a result, the findings described above are those of a large-scale case study. Clearly, more data will be available through longitudinal study of the individuals documented in the course of this investigation but, given the slow nature of the progression in this disease, such studies will be undertaken after an interval of several years. The general picture presented to the audiologist who must rehabilitate these cases is that of a progressive cochlear degeneration that affects only thresholds at first, and then rapidly diminishes speech intelligibility. The expected result is that, after normal language development, the patient may accept hearing aids well, encouraged by the support of the family. Performance and satisfaction with the hearing aids is good, until the onset of the speech intelligibility loss, at which time the patient will encounter serious difficulties and may reject hearing aids as unhelpful. As the histological and electrophysiological results indicate, however, the eighth nerve remains viable, especially in the younger affected members, and success with cochlear implantation may be expected. Audiologic counseling efforts are aided by the presence of role models and support from the other affected members of the family. Speech-language pathology services were not considered important by the members of this family since their speech production developed normally and has remained very good. Self-correction of speech was supported by hearing aids and cochlear implants (Case 5’s speech production was documented in Perkell, Lane, Svirsky, & Webster, 1992). These patients received genetic counseling and, due to the high penetrance of the disease, exhibited serious concerns regarding future generations and the hope of a cure.


1986 ◽  
Vol 51 (4) ◽  
pp. 362-369 ◽  
Author(s):  
Donna M. Risberg ◽  
Robyn M. Cox

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE instruments. The difference in input received at the microphone locations of the two types of hearing aids was measured for 10 different subjects and compared to the functional gain data. It was concluded that (a) for persons with mild to moderately severe hearing losses, appropriately adjusted custom ITE fittings typically yield speech intelligibility that is equal to the better OTE fitting identified in a comparative evaluation; and (b) gain prescriptions for ITE hearing aids should be adjusted to account for the high-frequency emphasis associated with in-the-concha microphone placement.


2008 ◽  
Vol 18 (1) ◽  
pp. 31-40 ◽  
Author(s):  
David J. Zajac

Abstract The purpose of this opinion article is to review the impact of the principles and technology of speech science on clinical practice in the area of craniofacial disorders. Current practice relative to (a) speech aerodynamic assessment, (b) computer-assisted single-word speech intelligibility testing, and (c) behavioral management of hypernasal resonance are reviewed. Future directions and/or refinement of each area are also identified. It is suggested that both challenging and rewarding times are in store for clinical researchers in craniofacial disorders.


Author(s):  
Isiaka Ajewale Alimi

Digital hearing aids addresses the issues of noise and speech intelligibility that is associated with the analogue types. One of the main functions of the digital signal processor (DSP) of digital hearing aid systems is noise reduction which can be achieved by speech enhancement algorithms which in turn improve system performance and flexibility. However, studies have shown that the quality of experience (QoE) with some of the current hearing aids is not up to expectation in a noisy environment due to interfering sound, background noise and reverberation. It is also suggested that noise reduction features of the DSP can be further improved accordingly. Recently, we proposed an adaptive spectral subtraction algorithm to enhance the performance of communication systems and address the issue of associated musical noise generated by the conventional spectral subtraction algorithm. The effectiveness of the algorithm has been confirmed by different objective and subjective evaluations. In this study, an adaptive spectral subtraction algorithm is implemented using the noise-estimation algorithm for highly non-stationary noisy environments instead of the voice activity detection (VAD) employed in our previous work due to its effectiveness. Also, signal to residual spectrum ratio (SR) is implemented in order to control the amplification distortion for speech intelligibility improvement. The results show that the proposed scheme gives comparatively better performance and can be easily employed in digital hearing aid system for improving speech quality and intelligibility.


Trials ◽  
2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Xin Ye ◽  
Dawei Zhu ◽  
Siyuan Chen ◽  
Xuefeng Shi ◽  
Rui Gong ◽  
...  

Abstract Background Hearing loss is quite prevalent and can be related to people’s quality of life. To our knowledge, there are limited studies assessing the efficacy of hearing interventions on quality of life in adults. Therefore, we aim to conduct a randomized controlled trial (RCT) to determine the impact and cost-effectiveness of community-based hearing rehabilitation on quality of life among Chinese adults with hearing loss. Methods/design In this two-arm feasibility study, participants aged 16 and above with some degree of hearing loss (n = 464) will be recruited from Linyi City, Shandong Province. They are randomly assigned to the treatment group or the control group. Those in the treatment group are prescribed with hearing aids, while those in the control group receive no intervention. Reinstruction in use of devices is provided for the treatment group during booster visits held 12 months post-randomization or unscheduled interim visits when necessary. Data are collected at baseline and the follow-up 20 months later. The primary outcome is changes in quality of life over a 20-month study period. Secondary outcomes include sub-dimensions in quality of life, physical functioning, chronic diseases, cognitive function, depression, social support, hospitalizations, falls, and healthcare costs. Finally, we will evaluate whether hearing aids intervention is cost-effective to apply in a large scale. Discussion The trial is designed to evaluate the impact and cost-effectiveness of a community-based rehabilitation intervention on quality of life among Chinese adults with hearing loss. We hope that it would help improve the well-being for Chinese adults and provide references in policy and practice for China and other countries. Trial registration Chinese Clinical Trial Registry ChiCTR1900024739. Registered on 26 July 2019.


2021 ◽  
Vol 11 (2) ◽  
pp. 200-206
Author(s):  
Gennaro Auletta ◽  
Annamaria Franzè ◽  
Carla Laria ◽  
Carmine Piccolo ◽  
Carmine Papa ◽  
...  

Background: The aim of this study was to compare, in users of bimodal cochlear implants, the performance obtained using their own hearing aids (adjusted with the standard NAL-NL1 fitting formula) with the performance using the Phonak Naìda Link Ultra Power hearing aid adjusted with both NAL-NL1 and a new bimodal system (Adaptive Phonak Digital Bimodal (APDB)) developed by Advanced Bionics and Phonak Corporations. Methods: Eleven bimodal users (Naìda CI Q70 + contralateral hearing aid) were enrolled in our study. The users’ own hearing aids were replaced with the Phonak Naìda Link Ultra Power and fitted following the new formula. Speech intelligibility was assessed in quiet and noisy conditions, and comparisons were made with the results obtained with the users’ previous hearing aids and with the Naída Link hearing aids fitted with the NAL-NL1 generic prescription formula. Results: Using Phonak Naìda Link Ultra Power hearing aids with the Adaptive Phonak Digital Bimodal fitting formula, performance was significantly better than that with the users’ own rehabilitation systems, especially in challenging hearing situations for all analyzed subjects. Conclusions: Speech intelligibility tests in quiet settings did not reveal a significant difference in performance between the new fitting formula and NAL-NL1 fittings (using the Naída Link hearing aids), whereas the performance difference between the two fittings was very significant in noisy test conditions.


Electronics ◽  
2021 ◽  
Vol 10 (7) ◽  
pp. 777
Author(s):  
Jan Leuchter ◽  
Radim Bloudicek ◽  
Jan Boril ◽  
Josef Bajer ◽  
Erik Blasch

The paper describes the influence of power electronics, energy processing, and emergency radio systems (ERS) immunity testing on onboard aircraft equipment and ground stations providing air traffic services. The implementation of next-generation power electronics introduces potential hazards for the safety and reliability of aircraft systems, especially the interferences from power electronics with high-power processing. The paper focuses on clearly identifying, experimentally verifying, and quantifiably measuring the effects of power electronics processing using switching modes versus the electromagnetic compatibility (EMC) of emergency radio systems with electromagnetic interference (EMI). EMI can be very critical when switching power radios utilize backup receivers, which are used as aircraft backup systems or airport last-resort systems. The switching power electronics process produces interfering electromagnetic energy to create problems with onboard aircraft radios or instrument landing system (ILS) avionics services. Analyses demonstrate significant threats and risks resulting from interferences between radio and power electronics in airborne systems. Results demonstrate the impact of interferences on intermediate-frequency processing, namely, for very high frequency (VHF) radios. The paper also describes the methodology of testing radio immunity against both weak and strong signals in accordance with recent aviation standards and guidance for military radio communication systems in the VHF band.