Evaluation of the Bond Strength of Resin Cements to New Lithium Disilicate-Reinforced Glass Ceramic Materials

2019 ◽  
Vol 11 (11) ◽  
pp. 1501-1509
Author(s):  
Lin-Lin Zhu ◽  
Yang Ji ◽  
Qiang Wang ◽  
Li-Hong Qiu
2018 ◽  
Vol 12 (3) ◽  
pp. 391-399 ◽  
Author(s):  
Оksana Savvova ◽  
◽  
Gennadii Voronov ◽  
Vitalii Topchyi ◽  
Yuliya Smyrnova ◽  
...  

2016 ◽  
Vol 17 (2) ◽  
pp. 149-153 ◽  
Author(s):  
Cristina Parise Gré ◽  
Renan C de Ré Silveira ◽  
Shizuma Shibata ◽  
Carlo TR Lago ◽  
Luiz CC Vieira

ABSTRACT Aim This study evaluated the influence of a silane-coupling agent on the bond strength of a self-adhesive cement and a conventional resin cement to a lithium disilicate glass ceramic. Materials and methods A total of eight ceramic blocks were fabricated and divided into four groups (n = 2). In groups 1 and 3, ceramic surfaces were etched with hydrofluoric acid 10% for 20 seconds, rinsed for 30 seconds, and air-dried. One layer of a silane agent was applied onto all ceramic specimens and air-dried for 30 seconds. In groups 2 and 4, ceramic surfaces were etched with hydrofluoric acid, rinsed, and air-dried without application of the silane-coupling agent. The ceramic blocks were bonded to a block of composite with a self-adhesive resin cement or with a conventional resin cement, according to the manufacturer's instructions. After 24 hours in distilled water at 37°C, the specimens were sectioned perpendicular to the bonding interface area to obtain beams with a bonding area of 0.8 mm2 and submitted to a microtensile bond strength test at a crosshead speed of 0.5 mm/min. Data were statistically analyzed with one-way analysis of variance and the Games–Howell post hoc test (p = 0.05). Fractured specimens were examined under optical microscopy at 40× magnification. Results Silanization resulted in higher microtensile bond strength compared to groups without silane. No significant differences were found between the conventional resin cement and the self-adhesive resin cement with silane agent (p = 0.983), and without silane agent (p = 0.877). Conclusion Silanization appears to be crucial for resin bonding to a lithium disilicate-based ceramic, regardless of the resin cement used. The self-adhesive resin cement performed as well as the conventional resin cement. Clinical significance Applying one layer of a silane-coupling agent after etching the ceramic surface with hydrofluoric acid 10% enhanced the bond strength between resin cements and a glass ceramic. How to cite this article Gré CP, de Ré Silveira RC, Shibata S, Lago CTR, Vieira LCC. Effect of Silanization on Microtensile Bond Strength of Different Resin Cements to a Lithium Disilicate Glass Ceramic. J Contemp Dent Pract 2016;17(2):149-153.


2015 ◽  
Vol 26 (5) ◽  
pp. 474-477 ◽  
Author(s):  
Samantha Schaffer Pugsley Baratto ◽  
Denis Roberto Falcão Spina ◽  
Carla Castiglia Gonzaga ◽  
Leonardo Fernandes da Cunha ◽  
Adilson Yoshio Furuse ◽  
...  

Abstract: The aim of this study was to evaluate the effect of silanization protocols on the bond strength of two resin cements to a lithium disilicate glass-ceramic. Thirty-two ceramic discs were assigned to 2 groups (n=16): G1 - dual-cured resin cement and G2 - light-cured resin cement. Four subgroups were evaluated according to the used silanization protocol. The glass-ceramic was etched with 10% hydrofluoric acid for 20 s and silane was applied for 1 min, as follows: CTL - according to the manufacturer's instructions; HA - dried with hot air; NWA - washed and dried with water and air at room temperature; HWA - washed and dried with hot water and hot air. Thereafter, adhesive was applied and light-cured for 20 s. Silicon molds were used to prepare resin cement cylinders (1x1 mm) on the ceramic surface. The specimens were stored in deionized water at 37 °C for 48 h and subjected to a micro-shear test. The data were submitted to statistical analysis (?#61537;=0.05). Group G1 showed higher bond strengths than G2, except for the CTL and NWA subgroups. Differences as function of the silanization protocol were only observed in G1: HWA (25.13±6.83)≥HA (22.95±7.78)≥CTL(17.44±7.24) ≥NWA(14.63±8.76). For G2 there was no difference among the subgroups. In conclusion, the silanization protocol affected the resin cement/ceramic bond strengths, depending on the material. Washing/drying with hot water and/or hot air increased only the bond strength of the dual-cured resin cement.


Molecules ◽  
2020 ◽  
Vol 25 (15) ◽  
pp. 3407
Author(s):  
Liliana Porojan ◽  
Roxana-Diana Vasiliu ◽  
Mihaela-Ionela Bîrdeanu ◽  
Sorin-Daniel Porojan

The development of various dental glass-ceramic materials and the evolution of novel processing technologies lead to an essential change in the clinical and technical workflow. The long-term success of a dental restoration treatment is defined by its durability, which is directly influenced by the oral environment. This study’s purpose was to evaluate the artificial aging behavior of nanostructured, respective microstructured ceramics related to surface topography, roughness, and optical properties. Six monolithic restoration materials were selected: milled lithium disilicate glass-ceramic (LDS-M) MT (medium translucency), hot-pressed lithium disilicate glass-ceramic (LDS-P) MT and HT (high translucency), milled zirconia-reinforced lithium silicate ceramic (ZLS-M) MT and hot-pressed zirconia-reinforced lithium silicate ceramic (ZLS-P) MT and HT, resulting n = 96 surfaces. All the samples were artificially aged by thermal cycling, and all investigations were made before and after thermal cycling. In terms of optical properties, differences recorded between ZLS and LDS ceramics are not significant. Thermal cycling increases the translucency of ZLS and LDS glass-ceramic materials significantly, with the most harmful effect on the pressed and polished samples. Micro- and nano roughness are significantly influenced by in vitro aging and a negative correlation was recorded. Glazed samples are characterized by significant rougher surfaces for all types of materials. On nanolevel, ZLS materials are significantly smoothed by thermal cycling.


Author(s):  
O.V. Savvova ◽  
G.K. Voronov ◽  
O.I. Fesenko ◽  
Yu.O. Smirnova ◽  
E. Bairamov

The need to improve the level of dental health of the population of Ukraine was identified. The prospects for the use of ceramic prostheses to provide quality medical care in dentistry have been established. An analytical review of various types of ceramic and glass-ceramic materials used as dental prostheses for tooth replacement: porcelain, alumina, zirconium oxide, glass-ceramics based on leucite and lithium disilicate and mica with the addition of fluorides. Peculiarities of the structure and operational properties of ceramic and glass-ceramic materials for dentistry have been identified, their advantages and disadvantages have been established. The effectiveness of the use of glass-ceramic materials based on lithium disilicate for dental prosthetics is substantiated. The basic lithium silicate system was selected and glasses for obtaining glass-ceramic crowns based on lithium disilicate by the method of high-temperature pressing and calcium phosphate-silicate system for obtaining glass-ceramic coatings were synthesized. The methodological approach to the development of glass-ceramic prostheses based on lithium disilicate is determined. The limits of the compositions of oxide components are determined and raw materials for the synthesis of the glass matrix are selected. The technological parameters of melting (T = 1350 – 1400ºС) and heat treatment with simultaneous formation of products (stage of nucleation T = 600 – 650ºС, τ = 30 – 60 min; stages of formation T = 900ºС, τ ≈ 20 min) are selected. The composition of fluoroapatite glass-ceramic coating for glazing of glass-ceramics and the mode of its firing (T = 800 – 850ºС, τ ≈ 1,0 – 1,5 min) were determined. The serviceability of the developed glass-ceramic samples DL st.glass, which were obtained by the technology of high-temperature pressing, are determined. The comparative analysis of glass-ceramic prostheses for dentistry allowed to establish that the operational properties of the developed glass-ceramic prostheses according to ISO 6872:2015 are at the level of world analogues. This will allow them to successfully compete in the Ukrainian market with well-known foreign counterparts and help ensure the social priorities of the state in the field of health care.


2020 ◽  
Vol 69 (3) ◽  
Author(s):  
Felipe Sczepanski ◽  
Cláudia R. Brunnquell ◽  
Sandrine B. Berger ◽  
Eloisa A. Paloco ◽  
Murilo B. Lopes ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document