Influences of Screw Access Hole and Mechanical Cycling on the Fracture Load of Implant-Supported Crowns

2019 ◽  
Vol 32 (5) ◽  
pp. 423-429 ◽  
Author(s):  
Luciano Rosa ◽  
Márcia Borba ◽  
Fernando Mallmann ◽  
Fernando Fornari ◽  
Alvaro Bona
2021 ◽  
pp. 1-11
Author(s):  
Shusen Zhang ◽  
Qi Cheng ◽  
Min Wei ◽  
Yuanjing Zhu ◽  
Yu Han ◽  
...  

2016 ◽  
Vol 10 (3) ◽  
pp. 181-188 ◽  
Author(s):  
Hadi Mokhtarpour ◽  
Reza Eftekhar Ashtiani ◽  
Minoo Mahshid ◽  
Farhad Tabatabaian ◽  
Marzieh Alikhasi

2018 ◽  
Vol 73 ◽  
pp. 97-104 ◽  
Author(s):  
Carlos López-Suárez ◽  
Raquel Castillo-Oyagüe ◽  
Verónica Rodríguez-Alonso ◽  
Christopher D. Lynch ◽  
María-Jesús Suárez-García

2019 ◽  
Vol 44 (6) ◽  
pp. E299-E308 ◽  
Author(s):  
PE Fontana ◽  
TC Bohrer ◽  
VF Wandscher ◽  
LF Valandro ◽  
IF Limberger ◽  
...  

SUMMARY Purpose: To investigate the influence of ferrule thickness on fracture resistance after mechanical cycling of teeth restored with different intracanal posts. Methods and Materials: One hundred twenty bovine incisor teeth were randomized into six study groups, based on the intracanal post used (fiber post or cast post and core) and the presence and thickness of a ferrule (without ferrule, presence of 0.5-mm or 1-mm-thick ferrule, retaining unaltered 2-mm ferrule height). The root posts and the metal crowns were cemented using an adhesive cement. The samples were subjected to mechanical cycling (at 37°C, 45°, 130 N, 2.2 Hz, and 2 × 106 pulses). Afterward, they were subjected to a fracture load test at a speed of 0.5 mm/min and on a 45° slope until failure occurred. The failures were classified as favorable or unfavorable. The fracture resistance data were analyzed with two-way analysis of variance and Tukey test. The chi-square test was used to analyze the pattern of failure. Results: When considering the cast post and core, the 1-mm ferrule thickness group presented a higher resistance to fracture than did the group in which a ferrule was not used (p=0.001). When using a glass fiber post, the groups showed no differences in fracture resistance. Overall, 96.7% of the specimens survived the mechanical cycling. Of the fractures, 58.6% of the fractures were unfavorable, while 41.6% were favorable. Conclusions: A thicker ferrule statistically increased the fracture resistance only for cast post and core when it was at least 1 mm thick, despite causing more unfavorable failures. Thus, ferrule thickness should be considered when choosing different intracanal posts, to reduce the occurrence of unfavorable failures. In the absence of a ferrule, the use of a cast post and core presents more favorable failures, and in the presence of a 1-mm-thick ferrule, the use of a glass fiber post seems to be the best clinical decision.


Materials ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 959
Author(s):  
Verónica Rodríguez ◽  
Celia Tobar ◽  
Carlos López-Suárez ◽  
Jesús Peláez ◽  
María J. Suárez

The aim of this study was to investigate the load to fracture and fracture pattern of prosthetic frameworks for tooth-supported fixed partial dentures (FPDs) fabricated with different subtractive computer-aided design and computer-aided manufacturing (CAD-CAM) materials. Materials and Methods: Thirty standardized specimens with two abutments were fabricated to receive three-unit posterior FDP frameworks with an intermediate pontic. Specimens were randomly divided into three groups (n = 10 each) according to the material: group 1 (MM)—milled metal; group 2 (L)—zirconia; and group 3 (P)—Polyetheretherketone (PEEK). The specimens were thermo-cycled and subjected to a three-point bending test until fracture using a universal testing machine (cross-head speed: 1 mm/min). Axial compressive loads were applied at the central fossa of the pontics. Data analysis was made using one-way analysis of variance, Tamhane post hoc test, and Weibull statistics (α = 0.05). Results: Significant differences were observed among the groups for the fracture load (p < 0.0001). MM frameworks showed the highest fracture load values. The PEEK group registered higher fracture load values than zirconia samples. The Weibull statistics corroborated these results. The fracture pattern was different among the groups. Conclusions: Milled metal provided the highest fracture load values, followed by PEEK, and zirconia. However, all tested groups demonstrated clinically acceptable fracture load values higher than 1000 N. PEEK might be considered a promising alternative for posterior FPDs.


Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3103
Author(s):  
Laurent Gremillard ◽  
Agnès Mattlet ◽  
Alexandre Mathevon ◽  
Damien Fabrègue ◽  
Bruno Zberg ◽  
...  

Due to growing demand for metal-free dental restorations, dental ceramics, especially dental zirconia, represent an increasing share of the dental implants market. They may offer mechanical performances of the same range as titanium ones. However, their use is still restricted by a lack of confidence in their durability and, in particular, in their ability to resist hydrothermal ageing. In the present study, the ageing kinetics of commercial zirconia dental implants are characterized by X-ray diffraction after accelerated ageing in an autoclave at different temperatures, enabling their extrapolation to body temperature. Measurements of the fracture loads show no effect of hydrothermal ageing even after ageing treatments simulated a 90-year implantation.


2012 ◽  
Vol 06 (02) ◽  
pp. 169-177
Author(s):  
Gislaine Cristine Martins ◽  
Alfonso Sánchez-Ayala ◽  
Paulo Henrique Perlatti D’Alpino ◽  
Abraham Lincoln Calixto ◽  
João Carlos Gomes ◽  
...  

ABSTRACTObjectives: Objective: To evaluate the effect of thermo-mechanical cycling (TMC) on the microleakage (μL) and axial gap width (AG) of Class V bonded restorations in premolars using self-etching adhesive systems. The bond strength of composite restorations to dentin (μTBS) using the same adhesives was also evaluated in third molars after water storage: 24 h and 6 months. The research hypotheses were tested for the results of two self-etching adhesives in comparison when a conventional two-step adhesive was used: (1) the μL and AG would be lower, regardless of TMC; (2) the μTBS of self-etching adhesives would be higher, irrespective of evaluation times.Methods: Sixty Class V composite restorations were made in 30 premolars and bonded with Adper Single Bond 2 (ASB2), AdheSE (ASE), and Adper Prompt L-Pop (APL-P) (n=20). Dentin μL and AG were immediately measured for half of the sample. The other half was evaluated after TMC. Eighteen third molars were also selected and bonded using the same adhesives to test the μTBS to dentin. Specimens were evaluated after 24 h and 6 months of water storage.Results: No differences in μL and AG were found among the groups (P>.05). The μTBS mean values were: ASB2>ASE>APL-P (P<.05); only Adper Single Bond 2 presented a significantly lower μTBS after water storage (P<.05)Conclusions: The bonding approach does not influence the microleakage and interfacial gap extension. Despite the decrease in the mean values, the bond strength to dentin of the conventional, two-step adhesive remains high after 6 months of water storage. (Eur J Dent 2012;6:169-177)


Sign in / Sign up

Export Citation Format

Share Document