Intravenous Administration of Human IgG to Newborn Infants: Changes in Serum Antibody Levels to GBS

Author(s):  
K. K. Christensen ◽  
P. Christensen ◽  
R. A. Seger
1984 ◽  
Vol 143 (2) ◽  
pp. 123-127 ◽  
Author(s):  
K. K. Christensen ◽  
P. Christensen ◽  
H. U. Bucher ◽  
G. Duc ◽  
C. H. Kind ◽  
...  

1994 ◽  
Vol 71 (01) ◽  
pp. 129-133 ◽  
Author(s):  
P J Declerck ◽  
S Vanderschueren ◽  
J Billiet ◽  
H Moreau ◽  
D Collen

SummaryStreptokinase (SK) is a routinely used thrombolytic agent but it is immunogenic and allergenic; staphylokinase (STA) is a potential alternative agent which is under early clinical evaluation. The comparative prevalence of antibodies against recombinant STA (STAR) and against SK was studied in healthy subjects and their induction with intravenous administration in small groups of patients.Enzyme-linked immunosorbent assays, using microtiter plates coated with STAR or SK and calibration with affinospecific human antibodies, revealed 2.1 to 65 μg/ml (median 11 μg/ml) anti-STAR antibodies and 0.9 to 370 μg/ml (median 18 μg/ml) anti-SK antibodies (p <0.001 vs anti-STAR antibodies) in plasma from 100 blood donors, with corresponding values of 0.6 to 100 μg/ml (median 7.1 μg/ml) and 0.4 to 120 μg/ml (median 7.3 μg/ml), respectively, in 104 patients with angina pectoris. Three out of 17 patients with Staphylococcus aureus bacteremia had significantly increased anti-STAR antibody levels (150, 75 and 75 μg/ml), and STAR neutralizing activities (2.2, 3.6 and 4.1 μg STAR neutralized per ml plasma, respectively). In 6 patients with acute myocardial infarction, given 10 mg STAR intravenously over 30 min, median anti-STAR antibody levels were 3.5 μg/ml at baseline, 2.9 μg/ml at 6 to 8 days and 1.2 μg/ml at 2 to 9 weeks, with median corresponding titers of STAR neutralizing activity at 2 to 9 weeks of 42 μg/ml plasma. Conversely, in 5 patients treated with 1,500,000 units SK over 60 min, median anti-SK antibodies increased from 2.9 μg/ml at baseline to 360 μg/ml at 5 to 10 days, with corresponding median SK neutralizing activities of 13 μg/ml. Antibodies against STAR did not cross-react with SK and vice versa.Plasma from human subjects contains low levels of circulating antibodies against recombinant staphylokinase, and intravenous administration of this compound boosts antibody titers. These antibodies do however not cross-react with streptokinase, whereby the use of these two immunogenic thrombolytic agents would not be mutually exclusive.


Parasitology ◽  
1999 ◽  
Vol 118 (6) ◽  
pp. 635-639 ◽  
Author(s):  
P. NIE ◽  
D. HOOLE

The humoral antibody response and the number of pronephric antibody-secreting cells were examined in naturally Bothriocephalus acheilognathi-infected carp. Cyprinus carpio, and in those injected intraperitoneally with an extract of the cestode. In the extract-injected fish, specific antibody was detected 3 weeks after a second injection given 2 weeks after the primary injection, and antibody levels persisted for more than 200 days. A third injection also enhanced the antibody level in the extract-injected carp. The numbers of antibody-secreting cells were significantly higher in carp injected 3 times with the extract than in the control. In naturally-infected fish, the serum antibody levels and the number of pronephric antibody-secreting cells were higher in infected fish than in uninfected individuals although this difference was not statistically significant. The relevance of these results to immune protection against infection is discussed.


Antibiotics ◽  
2021 ◽  
Vol 10 (6) ◽  
pp. 627
Author(s):  
Sławomir Letkiewicz ◽  
Marzanna Łusiak-Szelachowska ◽  
Ryszard Międzybrodzki ◽  
Maciej Żaczek ◽  
Beata Weber-Dąbrowska ◽  
...  

Patients with chronic urinary and urogenital multidrug resistant bacterial infections received phage therapy (PT) using intravesical or intravesical and intravaginal phage administration. A single course of PT did not induce significant serum antibody responses against administered phage. Whilst the second cycle of PT caused a significant increase in antibody levels, they nevertheless remained quite low. These data combined with good therapy results achieved in some patients suggest that this mode of PT may be an efficient means of therapy for urogenital infections and a reliable model for a clinical trial of PT.


1984 ◽  
Vol 19 (6) ◽  
pp. 614-617 ◽  
Author(s):  
H. K. Hrodek ◽  
R. Gmur ◽  
U. Saxlr ◽  
B. Guggenheim

2014 ◽  
Vol 80 (5) ◽  
pp. 377-379 ◽  
Author(s):  
G. Pidelaserra Martí ◽  
K. G. Isdahl Mohn ◽  
R. J. Cox ◽  
K. A. Brokstad

1998 ◽  
Vol 177 (6) ◽  
pp. 1710-1714 ◽  
Author(s):  
Veronika af Geijersstam ◽  
Mari Kibur ◽  
Zhaohui Wang ◽  
Pentti Koskela ◽  
Eero Pukka la ◽  
...  

1980 ◽  
Vol 89 (3_suppl) ◽  
pp. 117-120 ◽  
Author(s):  
P. Branefors ◽  
T. Dahlberg ◽  
O. Nylén

A series of episodes of acute otitis media were studied with reference to the bacterial findings in the nasopharynx and the specific antibody response in a group of children nine months to ten years of age, with previous frequent episodes of acute otitis media, Serum IgG, IgM and IgA antibody levels against five polysaccharide antigens, namely Haemophilus influenzae type b and Streptococcus pneumoniae types 3, 6, 19 and 23, were studied by means of an enzyme-linked immunosorbent assay. The selection of polysaccharide antigens was based on isolation frequency. The sera to be tested were tenfold serially diluted. An extinction of 0.2 over the base was taken as the end-point titer and expressed as in-log10. The results showed that most children including those under three years of age showed increasing homologous antibody titers at an infection, or had already initially very high antibody titers, especially of the IgG class. The titers reached levels of 104 to 105. In some cases, however, it could be shown that high serum antibody titers did not give protection against a new infection with the same serological type of bacteria. It was also demonstrated that most children, regardless of age, had IgG and IgM titers against the heterologous antigens. In some cases the levels were quite high (103 to 104). However, the IgA antibody levels were lower and in a considerable number of samples antibodies were not even detectable.


2020 ◽  
Author(s):  
Bertram Flehmig ◽  
Michael Schindler ◽  
Natalia Ruetalo ◽  
Ramona Businger ◽  
Manfred Bayer ◽  
...  

Background: Patients infected with SARS-CoV-2 exhibit a highly variable clinical course, varying from barely discernible signs of disease, to moderate flu-like symptoms and, occasionally, with life-threatening pneumonia and/or cytokine storm. The relationship between the nasopharyngeal virus load, IgA and IgG antibodies to both the S1-RBD-protein and the N-protein as well the neutralizing activity (NAbs) against SARS-CoV-2 in the blood of moderately afflicted COVID-19 patients has not been investigated longitudinally so far. Methods: Several new serological methods to examine these parameters were developed and validated for the longitudinal investigation in three patients of a family which underwent a mild course of COVID-19. Findings: We observed that the virus load had almost completely disappeared after about four weeks, whereas serum antibodies showed a contrasting course. IgA levels to S1-RBD-protein and, to a lesser extent, to the N-protein, peaked about three weeks after clinical disease onset but declined soon thereafter. IgG levels rose continuously, reaching a plateau approximately six weeks after disease onset. NAbs in serum reached a peak about four weeks after disease onset but dropped to a lower level about six weeks later. Interpretation: Our data establishes associations of virus neutralization and a serological immune response foremost against Sars-CoV-2 S1-RDB-protein in a longitudinal manner.


Sign in / Sign up

Export Citation Format

Share Document