scholarly journals Three Configurations of Compact Planar Multistub Microstrip Antennas for mmW Mobile Applications

2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Asma Lak ◽  
Zahra Adelpour ◽  
Homayoon Oraizi ◽  
Naser Parhizgar

Three configurations of compact planar multistub antennas are proposed in the frequency range of 27–29.5 GHz as candidates for the 5G standard frequency band. Each antenna consists of the same feeding part configuration but different structures for the dipole, director, and reflector parts. The feeding part is based on the substrate integrated waveguide (SIW) technology which results in compact size. The TE10 dominant mode is considered in the design procedure by HFSS software simulations. The proposed antennas have been simulated, fabricated, and measured (for S11, E, and H pattern). The simulation and measurement results show reasonable agreement for S11 and radiation patterns of E- and H-planes and impedance bandwidths. Moreover, for specific absorption rate (SAR) estimation, a three-layer human head model (skin, skull, and brain) is placed next to the antennas as the exposure source. The simulation results show the performance of the proposed antennas for low-SAR, which make them good candidates for safe usage concerning the negative impact of millimeter waves (mmWs) on human health. Finally, a comparison table is presented which verifies the compact size of our proposed antennas.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
A. Lak ◽  
Z. Adelpour ◽  
H. Oraizi ◽  
N. Parhizgar

AbstractIn this paper three different multi stub antenna arrays at 27–29.5 GHz are designed. The proposed antenna arrays consist of eight single elements. The structure of feeding parts is the same but the radiation elements are different. The feeding network for array is an eight way Wilkinson power divider (WPD). To guarantee the simulation results, one of the proposed structures is fabricated and measured (namely the characteristics of S11, E-, and H-plane patterns) which shows acceptable consistency with measurement results. The simulation results by CST and HFSS show reasonable agreement for reflection coefficient and radiation patterns in the E- and H- planes. The overall size of the proposed antenna in maximum case is 29.5 mm × 52 mm ×  0.38 mm  (2.8 $${{\varvec{\lambda}}}_{0}$$ λ 0 × 4.86$${{\varvec{\lambda}}}_{0}$$ λ 0 × 0.036$${{\varvec{\lambda}}}_{0}$$ λ 0 ). Moreover, for Specific Absorption Rate (SAR) estimation, a three-layer spherical human head model (skin, skull, and the brain) is placed next to the arrays as the exposure source. The simulation results show that the performance of proposed antennas as low-SAR sources makes them ideal candidates for the safe usage and lack of impact of millimeter waves (mmW) on the human health. In all three cases of SAR simulations the value of SAR1g and SAR10g are below the standard limitations.


2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Alireza Chamanzar ◽  
Marlene Behrmann ◽  
Pulkit Grover

AbstractA rapid and cost-effective noninvasive tool to detect and characterize neural silences can be of important benefit in diagnosing and treating many disorders. We propose an algorithm, SilenceMap, for uncovering the absence of electrophysiological signals, or neural silences, using noninvasive scalp electroencephalography (EEG) signals. By accounting for the contributions of different sources to the power of the recorded signals, and using a hemispheric baseline approach and a convex spectral clustering framework, SilenceMap permits rapid detection and localization of regions of silence in the brain using a relatively small amount of EEG data. SilenceMap substantially outperformed existing source localization algorithms in estimating the center-of-mass of the silence for three pediatric cortical resection patients, using fewer than 3 minutes of EEG recordings (13, 2, and 11mm vs. 25, 62, and 53 mm), as well for 100 different simulated regions of silence based on a real human head model (12 ± 0.7 mm vs. 54 ± 2.2 mm). SilenceMap paves the way towards accessible early diagnosis and continuous monitoring of altered physiological properties of human cortical function.


PeerJ ◽  
2017 ◽  
Vol 5 ◽  
pp. e4061 ◽  
Author(s):  
Awais Munawar Qureshi ◽  
Zartasha Mustansar

In this paper, we have presented a microwave scattering analysis from multiple human head models. This study incorporates different levels of detail in the human head models and its effect on microwave scattering phenomenon. Two levels of detail are taken into account; (i) Simplified ellipse shaped head model (ii) Anatomically realistic head model, implemented using 2-D geometry. In addition, heterogenic and frequency-dispersive behavior of the brain tissues has also been incorporated in our head models. It is identified during this study that the microwave scattering phenomenon changes significantly once the complexity of head model is increased by incorporating more details using magnetic resonance imaging database. It is also found out that the microwave scattering results match in both types of head model (i.e., geometrically simple and anatomically realistic), once the measurements are made in the structurally simplified regions. However, the results diverge considerably in the complex areas of brain due to the arbitrary shape interface of tissue layers in the anatomically realistic head model.After incorporating various levels of detail, the solution of subject microwave scattering problem and the measurement of transmitted and backscattered signals were obtained using finite element method. Mesh convergence analysis was also performed to achieve error free results with a minimum number of mesh elements and a lesser degree of freedom in the fast computational time. The results were promising and the E-Field values converged for both simple and complex geometrical models. However, the E-Field difference between both types of head model at the same reference point differentiated a lot in terms of magnitude. At complex location, a high difference value of 0.04236 V/m was measured compared to the simple location, where it turned out to be 0.00197 V/m. This study also contributes to provide a comparison analysis between the direct and iterative solvers so as to find out the solution of subject microwave scattering problem in a minimum computational time along with memory resources requirement.It is seen from this study that the microwave imaging may effectively be utilized for the detection, localization and differentiation of different types of brain stroke. The simulation results verified that the microwave imaging can be efficiently exploited to study the significant contrast between electric field values of the normal and abnormal brain tissues for the investigation of brain anomalies. In the end, a specific absorption rate analysis was carried out to compare the ionizing effects of microwave signals to different types of head model using a factor of safety for brain tissues. It is also suggested after careful study of various inversion methods in practice for microwave head imaging, that the contrast source inversion method may be more suitable and computationally efficient for such problems.


2021 ◽  
Vol 36 (2) ◽  
pp. 159-167
Author(s):  
Fatih Kaburcuk ◽  
Atef Elsherbeni

Numerical study of electromagnetic interaction between an adjacent antenna and a human head model requires long computation time and large computer memory. In this paper, two speeding up techniques for a dispersive algorithm based on finite-difference time-domain method are used to reduce the required computation time and computer memory. In order to evaluate the validity of these two speeding up techniques, specific absorption rate (SAR) and temperature rise distributions in a dispersive human head model due to radiation from an antenna integrated into a pair of smart glasses are investigated. The antenna integrated into the pair of smart glasses have wireless connectivity at 2.4 GHz and 5th generation (5G) cellular connectivity at 4.9 GHz. Two different positions for the antenna integrated into the frame are considered in this investigation. These techniques provide remarkable reduction in computation time and computer memory.


Author(s):  
X. Gary Tan ◽  
Amit Bagchi

Abstract Combat helmets have gone through many changes, from shells made of metal to advanced composites using Kevlar and Dyneema, along with introduction of pad suspensions to provide comfort and protection. Helmets have been designed to perform against ballistic and blunt impact threats. But, in today’s warfare, combat helmets are expected to protect against all three threats, blunt, ballistic impacts and blast effects to minimize traumatic brain injury (TBI) and provide a better thermal comfort. We are developing a helmet system analysis methodology integrating the effect of multiple threats, i.e., blast and blunt impacts, to achieve an optimal helmet system design, by utilizing multi-physics computational tools. We used a validated human head model to represent the warfighter’s head. The helmet composite shell was represented by an orthotropic elasto-plastic material model. A strain rate dependent model was employed for pad suspension material. Available dynamic loading data was used to calibrate the material parameters. Multiple helmet system configurations subjected to blast and blunt loadings were considered to quantify their influence on brain biomechanical response. Parametric studies were carried out to assess energy absorption for different suspension geometry and material morphology for different loadings. The resulting brain responses were used with published injury criteria to characterize the helmet system performance through a single metric for each threat type. Approaches to combine single-threat metrics to allow aggregating performance against multiple threats were discussed.


2013 ◽  
Vol 2013 ◽  
pp. 1-12 ◽  
Author(s):  
Maria Ida Iacono ◽  
Nikos Makris ◽  
Luca Mainardi ◽  
Leonardo M. Angelone ◽  
Giorgio Bonmassar

Deep brain stimulation (DBS) is an established procedure for the treatment of movement and affective disorders. Patients with DBS may benefit from magnetic resonance imaging (MRI) to evaluate injuries or comorbidities. However, the MRI radio-frequency (RF) energy may cause excessive tissue heating particularly near the electrode. This paper studies how the accuracy of numerical modeling of the RF field inside a DBS patient varies with spatial resolution and corresponding anatomical detail of the volume surrounding the electrodes. A multiscale model (MS) was created by an atlas-based segmentation using a 1 mm3head model (mRes) refined in the basal ganglia by a 200 μm2ex-vivo dataset. Four DBS electrodes targeting the left globus pallidus internus were modeled. Electromagnetic simulations at 128 MHz showed that the peak of the electric field of the MS doubled (18.7 kV/m versus 9.33 kV/m) and shifted 6.4 mm compared to the mRes model. Additionally, the MS had a sixfold increase over the mRes model in peak-specific absorption rate (SAR of 43.9 kW/kg versus 7 kW/kg). The results suggest that submillimetric resolution and improved anatomical detail in the model may increase the accuracy of computed electric field and local SAR around the tip of the implant.


Sign in / Sign up

Export Citation Format

Share Document