scholarly journals MRI-Based Multiscale Model for Electromagnetic Analysis in the Human Head with Implanted DBS

2013 ◽  
Vol 2013 ◽  
pp. 1-12 ◽  
Author(s):  
Maria Ida Iacono ◽  
Nikos Makris ◽  
Luca Mainardi ◽  
Leonardo M. Angelone ◽  
Giorgio Bonmassar

Deep brain stimulation (DBS) is an established procedure for the treatment of movement and affective disorders. Patients with DBS may benefit from magnetic resonance imaging (MRI) to evaluate injuries or comorbidities. However, the MRI radio-frequency (RF) energy may cause excessive tissue heating particularly near the electrode. This paper studies how the accuracy of numerical modeling of the RF field inside a DBS patient varies with spatial resolution and corresponding anatomical detail of the volume surrounding the electrodes. A multiscale model (MS) was created by an atlas-based segmentation using a 1 mm3head model (mRes) refined in the basal ganglia by a 200 μm2ex-vivo dataset. Four DBS electrodes targeting the left globus pallidus internus were modeled. Electromagnetic simulations at 128 MHz showed that the peak of the electric field of the MS doubled (18.7 kV/m versus 9.33 kV/m) and shifted 6.4 mm compared to the mRes model. Additionally, the MS had a sixfold increase over the mRes model in peak-specific absorption rate (SAR of 43.9 kW/kg versus 7 kW/kg). The results suggest that submillimetric resolution and improved anatomical detail in the model may increase the accuracy of computed electric field and local SAR around the tip of the implant.

2014 ◽  
Vol 2014 ◽  
pp. 1-14 ◽  
Author(s):  
Edward T. Dougherty ◽  
James C. Turner ◽  
Frank Vogel

Transcranial direct current stimulation (tDCS) continues to demonstrate success as a medical intervention for neurodegenerative diseases, psychological conditions, and traumatic brain injury recovery. One aspect of tDCS still not fully comprehended is the influence of the tDCS electric field on neural functionality. To address this issue, we present a mathematical, multiscale model that couples tDCS administration to neuron electrodynamics. We demonstrate the model’s validity and medical applicability with computational simulations using an idealized two-dimensional domain and then an MRI-derived, three-dimensional human head geometry possessing inhomogeneous and anisotropic tissue conductivities. We exemplify the capabilities of these simulations with real-world tDCS electrode configurations and treatment parameters and compare the model’s predictions to those attained from medical research studies. The model is implemented using efficient numerical strategies and solution techniques to allow the use of fine computational grids needed by the medical community.


2018 ◽  
Vol 5 (7) ◽  
pp. 180319
Author(s):  
Awais Munawar Qureshi ◽  
Zartasha Mustansar ◽  
Samah Mustafa

In this paper, a detailed analysis of microwave (MW) scattering from a three-dimensional (3D) anthropomorphic human head model is presented. It is the first time that the finite-element method (FEM) has been deployed to study the MW scattering phenomenon of a 3D realistic head model for brain stroke detection. A major contribution of this paper is to add anatomically more realistic details to the human head model compared with the literature available to date. Using the MRI database, a 3D numerical head model was developed and segmented into 21 different types through a novel tissue-mapping scheme and a mixed-model approach. The heterogeneous and frequency-dispersive dielectric properties were assigned to brain tissues using the same mapping technique. To mimic the simulation set-up, an eight-elements antenna array around the head model was designed using dipole antennae. Two types of brain stroke (haemorrhagic and ischaemic) at various locations inside the head model were then analysed for possible detection and classification. The transmitted and backscattered signals were calculated by finding out the solution of the Helmholtz wave equation in the frequency domain using the FEM. FE mesh convergence analysis for electric field values and comparison between different types of iterative solver were also performed to obtain error-free results in minimal computational time. At the end, specific absorption rate analysis was conducted to examine the ionization effects of MW signals to a 3D human head model. Through computer simulations, it is foreseen that MW imaging may efficiently be exploited to locate and differentiate two types of brain stroke by detecting abnormal tissues’ dielectric properties. A significant contrast between electric field values of the normal and stroke-affected brain tissues was observed at the stroke location. This is a step towards generating MW scattering information for the development of an efficient image reconstruction algorithm.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Sangjun Lee ◽  
Jimin Park ◽  
Jinuk Kwon ◽  
Dong Hwan Kim ◽  
Chang-Hwan Im

AbstractTransorbital electrical stimulation (tES) has been studied as a new noninvasive method for treating intractable eye diseases by delivering weak electrical current to the eye through a pair of electrodes attached to the skin around the eye. Studies have reported that the therapeutic effect of tES is determined by the effective stimulation of retinal cells that are densely distributed in the posterior part of the retina. However, in conventional tES with a pair of electrodes, a greater portion of the electric field is delivered to the anterior part of the retina. In this study, to address this issue, a new electrode montage with multiple electrodes was proposed for the effective delivery of electric fields to the posterior retina. Electric field analysis based on the finite element method was performed with a realistic human head model, and optimal injection currents were determined using constrained convex optimization. The resultant electric field distributions showed that the proposed multi-channel tES enables a more effective stimulation of the posterior retina than the conventional tES with a pair of electrodes.


2021 ◽  
Vol 83 (6) ◽  
pp. 109-115
Author(s):  
Anis Nisma Yanti ◽  
Marlin Ramadhan Baidillah ◽  
Triwikantoro Triwikantoro ◽  
Endarko Endarko ◽  
Warsito Purwo Taruno

The wire-mesh capacitance tomography (WMCT) has been applied to visualize 2D of the distribution of electric field intensity in the treatment planning system (TPS) of electro-capacitive cancer therapy (ECCT) using human head model. WMCT is proposed in this study to estimate accurately the distribution of electric field intensity which is the main optimum factors of ECCT in order to compensate the inaccuracy of TPS ECCT simulation. The experimental and simulation studies were conducted with wire-mesh sensor consisted of 8×8 wire matrix of copper in human head model using two type of helmet ECCT. The result of electric field value at the intersection wire-mesh have been compared between experimental studies and simulation studies. The electric field average value resulted from ECCT helmet-1 is higher than ECCT helmet-2. The average electric field generated by the ECCT helmet-1 is 1585.72 V/m in an air medium, 97.43 V/m in grey matter and 80.58 V/m in the cancer. While the average electric field generated by the ECCT helmet-2 is 1413.28 V/m in an air medium, 64.20 V/m in grey matter and 52.65 V/m in the cancer. ECCT helmet-1 and helmet-2 result the different of electric field distribution pattern. ECCT helmet-1 is more optimal for used to patient has cancer position in the right and bottom, while ECCT helmet-2 is more optimal for used to patient has cancer position in the top and bottom. 


Author(s):  
Alexander V. Ashikhmin ◽  
Rubin R. Aliev

AbstractWe simulated the electric current distribution in the brain during transcranial direct current stimulation (tDCS) using an anatomically accurate human head model. We estimated an effect of common electrode montages on spatial distribution of the electric field during tDCS procedure and analyzed a sensitivity of the technique to variations of electrode size and orientation. We concluded that the used electrode montages are stable with respect to minor changes in electrode size and position, while an assumption of homogeneity and isotropy of the head model results in crucial changes of the electric field distribution. We determined the electrode montages suited to deliver strong effect on hippocampus and cerebellum.


2015 ◽  
Vol 08 (03) ◽  
pp. 1540003 ◽  
Author(s):  
Yan Ye ◽  
Xiaoping Li ◽  
Tiecheng Wu ◽  
Zhe Li ◽  
Wenwen Xie

Deep brain activity is conventionally recorded with surgical implantation of electrodes. During the neurosurgery, brain tissue damage and the consequent side effects to patients are inevitably incurred. In order to eliminate undesired risks, we propose that deep brain activity should be measured using the noninvasive scalp electroencephalography (EEG) technique. However, the deeper the neuronal activity is located, the noisier the corresponding scalp EEG signals are. Thus, the present study aims to evaluate whether deep brain activity could be observed from EEG recordings. In the experiment, a three-layer cylindrical head model was constructed to mimic a human head. A single dipole source (sine wave, 10 Hz, altering amplitudes) was embedded inside the model to simulate neuronal activity. When the dipole source was activated, surface potential was measured via electrodes attached on the top surface of the model and raw data were recorded for signal analysis. Results show that the dipole source activity positioned at 66 mm depth in the model, equivalent to the depth of deep brain structures, is clearly observed from surface potential recordings. Therefore, it is highly possible that deep brain activity could be observed from EEG recordings and deep brain activity could be measured using the noninvasive scalp EEG technique.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2670
Author(s):  
Thomas Quirin ◽  
Corentin Féry ◽  
Dorian Vogel ◽  
Céline Vergne ◽  
Mathieu Sarracanie ◽  
...  

This paper presents a tracking system using magnetometers, possibly integrable in a deep brain stimulation (DBS) electrode. DBS is a treatment for movement disorders where the position of the implant is of prime importance. Positioning challenges during the surgery could be addressed thanks to a magnetic tracking. The system proposed in this paper, complementary to existing procedures, has been designed to bridge preoperative clinical imaging with DBS surgery, allowing the surgeon to increase his/her control on the implantation trajectory. Here the magnetic source required for tracking consists of three coils, and is experimentally mapped. This mapping has been performed with an in-house three-dimensional magnetic camera. The system demonstrates how magnetometers integrated directly at the tip of a DBS electrode, might improve treatment by monitoring the position during and after the surgery. The three-dimensional operation without line of sight has been demonstrated using a reference obtained with magnetic resonance imaging (MRI) of a simplified brain model. We observed experimentally a mean absolute error of 1.35 mm and an Euclidean error of 3.07 mm. Several areas of improvement to target errors below 1 mm are also discussed.


Sign in / Sign up

Export Citation Format

Share Document