scholarly journals Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients

2020 ◽  
Vol 2020 ◽  
pp. 1-9 ◽  
Author(s):  
Jinhai Huang ◽  
Yuyu Zhao ◽  
Giacomo Savini ◽  
Guanshun Yu ◽  
Jinjin Yu ◽  
...  

Purpose. To comprehensively assess the reliability of a new optical biometer (IOLMaster 700), based on swept-source optical coherence tomography (SS-OCT) and comparison with a standard biometer (IOLMaster 500), in healthy children, adults, and cataract patients. Methods. A total of 301 eyes from 301 consecutive subjects were enrolled prospectively. Two experienced operators measured each eye three times consecutively with the IOLMaster 700. The axial length (AL), keratometry (K), anterior chamber depth (ACD), lens thickness (LT), central corneal thickness (CCT), and white-to-white (WTW) distance were recorded. Intraoperator repeatability and interoperator reproducibility of the IOLMaster 700 were analyzed using the test-retest (TRT), coefficients of variation (CoV), and intraclass correlation coefficients (ICCs). The agreement between the two devices was evaluated using the Bland–Altman method. Results. The repeatability and reproducibility of the SS-OCT optical biometer were high for all ocular biometry parameters in all groups, except for the WTW in cataract patients (TRT, 0.27–0.44 mm; ICC, 0.86–0.95). The reproducibility of averaged measurements from three consecutive readings (TRT : AL = 0.02 mm, CCT = 5.41 μm, ACD = 0.03 mm, LT = 0.03 mm, Km = 0.17 D, and WTW = 0.22 mm) was higher than the reproducibility of single measurements (TRT : AL = 0.04 mm, CCT = 7.43 μm, ACD = 0.06 mm, LT = 0.05 mm, Km = 0.26 D, and WTW = 0.35 mm) in the three groups. The consistency in the data between the two biometers was high, with narrow 95% LoAs in the three groups. Conclusion. Repeatability and reproducibility of the new SS-OCT optical biometer were excellent and consistent with that of the standard biometer with respect to healthy children, healthy adults, and cataract patients.

2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Xi Feng ◽  
Yong Wang ◽  
Jianheng Liang ◽  
Yali Xu ◽  
Julio Ortega-Usobiaga ◽  
...  

Objective. This study aimed to analyze the distribution of lens thickness (LT) and its associations in age-related cataract patients based on swept-source optical coherence tomography (SS-OCT). Methods. This cross-sectional study included 59,726 Chinese age-related cataract patients. Only right-eye data were included in the study. Repeated measures of ocular parameters were performed using an IOL Master 700 device. The distributions of ocular biometric data including anterior chamber depth (ACD), LT, axial length (AL), central corneal thickness (CCT), white-to-white (WTW), and mean keratometry (MK) and their associations with age were assessed. The anterior segment (AS) was measured as the sum of CCT, ACD, and LT, while the vitreous chamber depth (VCD) was calculated as the difference between AL and AS. The values of LT : AL, AS : AL, and VCD : AL in different AL groups and their changes are the main outcome measures used to observe the proportion of the anterior and posterior segments of the eye. Results. Biometric data were available for 59,726 individuals. The mean age was 68.81 years (range = 40–100); 40.62% were male and 59.38% were female. Mean anterior chamber depth (ACD) was 3.02 ± 0.44 mm, mean LT was 4.51 ± 0.44 mm, mean axial length (AL) was 23.89 ± 1.92 mm, mean central corneal thickness (CCT) was 0.53 ± 0.03 mm, mean white-to-white (WTW) was 11.64 ± 0.44 mm, and mean keratometry (MK) was 44.27 ± 1.65 diopter. Female patients had shorter AL, shallower ACD, smaller CCT and WTW, decreased LT, and steeper corneas ( p  < 0.005). ACD revealed the strongest negative correlation ( p  ≤ 0.001, r = –0.682) with LT. Age ( p  ≤ 0.001, r = 0.348) showed a moderate positive correlation, whereas MK ( p  < 0.05, r = 0.011), CCT ( p  ≤ 0.001, r = 0.041) had a weak positive correlation and WTW ( p  ≤ 0.001, r = –0.034) had a weak negative correlation with LT. A nonlinear correlation was found between LT and AL. LT increased with age in both males and females. LT changed variably in eyes with AL less than 27 mm, LT decreased as AL increased, then LT gradually increased as AL increased in extremely long and extra-long eyes ( p  ≤ 0.001). LT : AL and AS : AL decreased as AL increased, VCD : AL gradually increased as AL increased in highly myopic eyes, and VCD : AL increased by about 0.01 for every 1 mm increase in AL. Conclusions. Among Chinese age-related cataract patients, we found LT to have the strongest relation with ACD. The lens was thicker in elderly patients and women. The correlation between LT and AL is not a simple negative correlation; with the increase of age, LT decreases first and then increases. The proportion of VCD is constantly rising with the elongation of AL.


2017 ◽  
Vol 2017 ◽  
pp. 1-5 ◽  
Author(s):  
Soyeon Jung ◽  
Hee Seung Chin ◽  
Na Rae Kim ◽  
Kang Won Lee ◽  
Ji Won Jung

Purpose. To assess the repeatability and agreement of parameters obtained with two biometers and to compare the predictability. Methods. Biometry was performed on 101 eyes with cataract using the IOLMaster 700 and the Galilei G6. Three measurements were obtained per eye with each device, and repeatability was evaluated. The axial length (AL), anterior chamber depth (ACD), keratometry (K), white-to-white (WTW) corneal diameter, central corneal thickness (CCT), and lens thickness (LT) were measured and postoperative predictability was compared. Results. Measurements could not be obtained with the IOLMaster 700 in one eye and in seven eyes with the Galilei G6 due to dense cataract. Both the IOLMaster 700 and Galilei G6 showed good repeatability, although the IOLMaster 700 showed better repeatability than the Galilei G6. There were no statistically significant differences in AL, ACD, steepest K, WTW, and LT (P>0.050), although flattest K, mean K, and CCT differed (P<0.050). The proportion of eyes with an absolute prediction error within 0.5 D was 85.0% for the IOLMaster 700 and was 80.0% for the Galilei G6 based on the SRK/T formula. Conclusions. Two biometers showed high repeatability and relatively good agreements. The swept-source optical biometer demonstrated better repeatability, penetration, and an overall lower prediction error.


2015 ◽  
Vol 2015 ◽  
pp. 1-10 ◽  
Author(s):  
Anna K. Nowinska ◽  
Sławomir J. Teper ◽  
Dominika A. Janiszewska ◽  
Anita Lyssek-Boron ◽  
Dariusz Dobrowolski ◽  
...  

Purpose.To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs).Methods. Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots.Results.Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters.Conclusions.Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Tommy C. Y. Chan ◽  
Marco C. Y. Yu ◽  
Vivian Chiu ◽  
Gilda Lai ◽  
Christopher K. S. Leung ◽  
...  

AbstractTo evaluate the repeatability and agreement of corneal and biometry measurements obtained with two swept-source optical coherence tomography (SSOCT) and a partial coherence interferometry-based device. This is a cross-sectional study. Forty-eight eyes of 48 patients had three consecutive measurements for ANTERION (Heidelberg Engineering, Germany), CASIAII (Tomey, Japan) and IOLMaster500 (Carl Zeiss Meditec, USA) on the same visit. Mean keratometry (Km), central corneal thickness (CCT), anterior chamber depth (ACD) and axial length (AL) were recorded. Corneal astigmatic measurements were converted into vector components—J0 and J45. Intra-device repeatability and agreements of measurements amongst the devices were evaluated using repeatability coefficients (RCs) and Bland–Altman plots, respectively. All devices demonstrated comparable repeatability for Km (p ≥ 0.138). ANTERION had the lowest RC for J0 amongst the devices (p ≤ 0.039). Systematic difference was found for the Km and J0 obtained with IOLMaster500 compared to either SSOCTs (p ≤ 0.010). The ACD and AL measured by IOLMaster500 showed a higher RC compared with either SSOCTs (p < 0.002). Systematic difference was found in CCT and ACD between the two SSOCTs (p < 0.001), and in AL between ANTERION and IOLMaster500 (p < 0.001), with a mean difference of 1.6 µm, 0.022 mm and 0.021 mm, respectively. Both SSOCTs demonstrated smaller test–retest variability for measuring ACD and AL compared with IOLMaster500. There were significant disagreement in keratometry and AL measurements between the SSOCTs and PCI-based device; their measurements should not be considered as interchangeable.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Richul Oh ◽  
Joo Youn Oh ◽  
Hyuk Jin Choi ◽  
Mee Kum Kim ◽  
Chang Ho Yoon

Abstract Background Precise measurement of ocular biometry is critical for determining intraocular lens power. Newly developed swept-source optical coherence tomography (SS-OCT) - based ocular biometric devices, ANTERION and CASIA2 provide ocular biometric measurements as IOLMaster 700. This study aimed to assess agreement between three devices. Methods This retrospective comparative study includes patients with cataract who underwent ocular biometric measurements with three devices, ANTERION, CASIA2, and IOLMaster 700, at Seoul National University Hospital, in April 2020. Anterior keratometry, total keratometry, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and axial length (AL) were the main parameters for the comparison. To assess the agreement between the devices, intraclass coefficient (ICC) and Bland-Altman analysis with 95% limits of agreement (LoA) were used. Results A total of 47 eyes of 29 patients were measured with three devices. Average anterior keratometry showed excellent agreement (ICC ≥ 0.989), and the mean difference was less than 0.1 D. However, the ICC of the total average keratometry ranged from 0.808 to 0.952, and the difference was more than 0.43 D. The AL measured by ANTERION and IOLMaster 700 showed excellent agreement (ICC = 0.999), and the mean difference was 0.005 mm. The ANTERION and IOLMaster 700 did not obtain AL in six (12.8%) and three (6.4%) cases, respectively (P = 0.001 by Fisher’s exact test). The CCT, ACD, and LT also showed excellent agreement (ICC > 0.9). Conclusions The new SS-OCT-based devices, ANTERION, and CASIA2 showed a good agreement with IOLMaster 700 in measuring ocular biometry except for the total keratometry. The AL of ANTERION and IOLMaster 700 showed excellent agreement.


2021 ◽  
Author(s):  
Qiong Lei ◽  
Haixia Tu ◽  
Xi Feng ◽  
Yong Wang

Abstract Background: To create an anterior chamber depth (ACD) regression model for adult cataract surgery candidates from China, and to evaluate the distribution of their ocular biometric parameters.Methods: The ocular biometric records of 28,709 right eyes of cataract surgery candidates who were treated at Aier Eye Hospitals in nine cities from 2018 to 2019 were retrospectively analyzed. All measurements were taken with IOLMaster 700. We included patients who were at least 40 years old and were diagnosed with cataract.Results: The mean age of the patients was 68.6 ± 11.0 years. The mean values recorded were as follows: axial length (AL), 24.17 ± 2.47 mm; mean keratometry (Km) value, 44.09 ± 3.25 D; corneal astigmatism (CA), 1.06 ± 0.98 D; ACD, 3.02 ± 0.45 mm; lens thickness (LT), 4.52 ± 0.45 mm; central corneal thickness (CCT), 0.534 ± 0.04 mm; and white to white (WTW) corneal diameter, 11.64 ± 0.46 mm. The proportion of patients with long axial length (AL >25 mm) decreased with age. ACD, LT, AL, Km, WTW, and age were correlated. In the multivariate regression analysis of ACD, which included LT, AL, WTW, sex, Km, CCT, and age, there was a reasonable prediction with adjusted R2 = 0.629.Conclusions: The results show that high myopes are inclined to schedule cataract surgery at a younger age. LT and AL were found to be important factors that affect ACD. This study provides reference data for cataract patients from China.


2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Sisi Chen ◽  
Rongrong Gao ◽  
Colm McAlinden ◽  
Junming Ye ◽  
Yiran Wang ◽  
...  

Purpose. To compare central corneal thickness (CCT), aqueous depth (AQD), and anterior chamber depth (ACD) measurements using the swept-source (CASIA SS-1000, Tomey, Japan) and time-domain (Visante, Carl Zeiss Meditec, USA) anterior segment optical coherence tomographers (OCT) in normal eyes. Methods. Sixty-eight eyes of 68 subjects were included. Three consecutive scans of each subject were obtained using both devices in a random order by one experienced operator. Standard deviation (Sw), coefficient of repeatability (CoR), coefficients of variation (CoV), and intraclass correlation coefficients (ICC) were used to evaluate the intraoperator repeatability. Agreement was assessed using the Bland–Altman plots and 95% limits of agreement (LoA). Results. All measurements of the swept-source OCT (SS-OCT) and time-domain OCT (TD-OCT) showed high repeatability with low CoR (CCT: 2.34 μm and 6.16 μm; AQD: 0.05 mm and 0.09 mm; ACD: 0.06 mm and 0.09 mm), low CoV (CCT: 0.16% and 0.42%; AQD: 0.61% and 0.97%; ACD: 0.53% and 0.83%), and high ICC (>0.98). The mean CCT with SS-OCT was slightly thicker than the results with TD-OCT (difference = 4.55 ± 2.62 μm, P<0.001). There was no statistically significant difference in AQD or ACD measurements between the two devices (0.01 ± 0.05 mm, P=0.111; 0.02 ± 0.05 mm, P=0.022, respectively). The 95% LoA between the SS-OCT and TD-OCT were −0.59 to 9.69 μm for CCT, −0.10 to 0.12 mm for AQD, and −0.09 to 0.12 mm for ACD. Conclusions. High levels of repeatability and agreement were found between the two devices for all three parameters, suggesting interchangeability. SS-OCT demonstrated superior repeatability compared with TD-OCT.