scholarly journals Field Assessment of Neighboring Building and Tree Shading Effects on the 3D Radiant Environment and Human Thermal Comfort in Summer within Urban Settlements in Northeast China

2020 ◽  
Vol 2020 ◽  
pp. 1-19
Author(s):  
Jing Du ◽  
Lin Liu ◽  
Xin Chen ◽  
Jing Liu

Shading is one of the most effective strategies to mitigate urban local-scale heat stress during summer. Therefore, this study investigates the effects of shading caused by buildings and trees via exhaustive field measurement research on urban outdoor 3D radiant environment and human thermal comfort. We analyzed the characteristics of micrometeorology and human thermal comfort at shaded areas, and compared the difference between building and tree shading effects as well as that between shaded and sunlit sites. The results demonstrate that mean radiant temperature Tmrt (mean reduction values of 28.1°C for tree shading and 28.8°C for building shading) decreased considerably more than air temperature Ta (mean reduction values of 1.9°C for tree shading and 1.2°C for building shading) owing to shading; furthermore, the reduction effect of shading on UTCI synthesized the variation in the above two parameters. Within the shaded areas, short-wave radiant components (mean standardized values of 0.104 for tree shading and 0.087 for building shading) decreased considerably more than long-wave radiant components (mean standardized values of 0.848 for tree shading and 0.851 for building shading) owing to shading; the proportion of long-wave radiant flux densities absorbed by the reference standing person was high, leading to a relatively high long-wave mean radiant temperature, and R2 between long-wave mean radiant temperature and air temperature exceeded 0.8. Moreover, the directional sky view factor (SVF) was utilized in this study, and it showed significant positive correlation with short-wave radiant flux densities, but no statistically evident correlation with long-wave radiant flux densities. Meanwhile, Tmrt was most relevant with SVFS⟶ with R2 of 0.9756. Furthermore, UTCI rose two categories at the sunlit areas compared with that at the shaded areas. In contrast, Ta and Tmrt played the first positive role in UTCI at shaded and sunlit areas, respectively.

2011 ◽  
Vol 243-249 ◽  
pp. 4905-4908
Author(s):  
Xue Min Sui ◽  
Xu Zhang ◽  
Guang Hui Han

Relative humidity is an important micro-climate parameter in radiant cooling environment. Based on the human thermal comfort model, this paper studied the effect on PMV index of relative humidity, and studied the relationship of low mean radiant temperature and relative humidity, drew the appropriate design range of indoor relative humidity for radiant cooling systems.The results show that high relative humidity can compensate for the impact on thermal comfort of low mean radiant temperature, on the premise of achieving the same thermal comfort requirements. However, because of the limited compensation range of relative humidity, together with the constraints for it due to anti-condensation of radiant terminal devices, the design range of relative humidity should not be improved, and it can still use the traditional air-conditioning design standards.


2011 ◽  
Vol 3 (1) ◽  
Author(s):  
Noémi Kántor ◽  
János Unger

AbstractThis paper gives a review on the topic of the mean radiant temperature Tmrt, the most important parameter influencing outdoor thermal comfort during sunny conditions. Tmrt summarizes all short wave and long wave radiation fluxes reaching the human body, which can be very complex (variable in spatial and also in temporal manner) in urban settings. Thermal comfort researchers and urban planners need easy and sound methodological approaches to assess Tmrt. After the basics of the Tmrt calculation some of the methods suitable for obtaining Tmrt also in urban environments will be presented.. Two of the discussed methods are based on instruments which measure the radiation fluxes integral (globe thermometer, pyranometer-pyrgeometer combination), and three of the methods are based on modelling the radiation environment with PC software (RayMan, ENVI-met and SOLWEIG).


1977 ◽  
Vol 78 (1) ◽  
pp. 17-26 ◽  
Author(s):  
R. M. Smith ◽  
A. Rae

SUMMARYThe patient is identified as being of prime importance for comfort standards in hospital ward areas, other ward users being expected to adjust their dress to suit the conditions necessary for patient comfort. A study to identify the optimum steady state conditions for patient comfort is then described.Although this study raises some doubts as to the applicability of the standard thermal comfort assessment techniques to ward areas, it is felt that its results give a good indication of the steady-state conditions preferred by the patients. These were an air temperature of between 21.5° and 22° C and a relative humidity of between 30% and 70%, where the air velocity was less than 0.1 m/s and the mean radiant temperature was close to air temperature.


2020 ◽  
Vol 13 (7) ◽  
pp. 3055-3065 ◽  
Author(s):  
Dominik Fröhlich ◽  
Andreas Matzarakis

Abstract. In the frame of the project “MOSAIK – Model-based city planning and application in climate change”, a German-wide research project within the call “Urban Climate Under Change” ([UC]2) funded by the German Federal Ministry of Education and Research (BMBF), a biometeorology module was implemented into the Parallelized Large-Eddy Simulation Model (PALM) system. The new biometeorology module is comprised of methods for the calculation of UV-exposure quantities, a human–biometeorologically weighted mean radiant temperature (Tmrt), as well as for the estimation of human thermal comfort or stress. The latter is achieved through the implementation of the three widely used thermal indices: perceived temperature (PT), Universal Thermal Climate Index (UTCI), as well as physiologically equivalent temperature (PET). Comparison calculations were performed for the PT, UTCI and PET indices based on the SkyHelios model and showing PALM calculates higher values in general. This is mostly due to a higher radiational gain leading to higher values of mean radiant temperature. For a more direct comparison, the PT, PET and UTCI indices were calculated by the biometeorology module, as well as the programs provided by the attachment to Verein Deutscher Ingenieure (VDI) guideline 3787, as well as by the RayMan model based on the very same input dataset. Results show deviations below the relevant precision of 0.1 K for PET and UTCI and some deviations of up to 2.683 K for PT caused by repeated unfavorable rounding in very rare cases (0.027 %).


2019 ◽  
Author(s):  
Dominik Fröhlich ◽  
Andreas Matzarakis

Abstract. In the frame of the project MOSAIK – Model–based city planning and application in climate change, a German-wide research project within the call Urban Climate Under Change ([UC]2) funded by the German Federal Ministry of Education and Research (BMBF), a biometeorology module was implemented into the PALM model system. The new biometeorology module comprises of methods for the calculation of uv-exposure quantities, a human–biometeorologically weighted mean radiant temperature (Tmrt), as well as for the estimation of human thermal comfort or stress. The latter is achieved through the implementation of the three widely–used thermal indices Perceived Temperature (PT), Universal Thermal Climate Index (UTCI), as well as Physiologically Equivalent Temperature (PET) together with a newly developed instationary index instationary Perceived Temperature (iPT) based on PT for use with the multi–agent model. Comparison calculations were performed for the indices PT, UTCI and PET based on the SkyHelios model and showing PALM calculates higher values in general. This is mostly due to a higher radiational gain leading to higher values of mean radiant temperature. For a more direct comparison, the indices PT, PET and UTCI were calculated by the biometeorology module, as well as the programs provided by the attachment to the VDI guideline 3787, as well as by the RayMan model based on the very same input dataset. Results show deviations below rounding precision (less than 0.1 K) for PET and UTCI and some deviations of up to 2.683 K for PT caused by rounding leading to the selection of a different clothing insulation step in very rare cases (0.027 %).


Atmosphere ◽  
2018 ◽  
Vol 9 (6) ◽  
pp. 210 ◽  
Author(s):  
Satoshi Hirabayashi ◽  
Tsutomu Abe ◽  
Fumiko Imamura ◽  
Chie Morioka

Heat stress is an issue for marathon races in the summer, such as the one planned for the 2020 Tokyo Summer Olympic games. The Tokyo Metropolitan Government is planning to grow existing street trees’ canopies to enlarge their shade to reduce air temperature and solar radiation. To formulate a baseline to assess the effect of street trees and buildings on human thermal comfort, Distributed-COMfort FormulA (D-COMFA), a prototype of a distributed computer model using a geographic information system (GIS) was developed. D-COMFA calculates the energy budget of a human body on a 1 m cell basis, using readily available datasets such as weather measurements and polygon data for street structures. D-COMFA was applied to a street segment along the marathon course in Tokyo on an hourly-basis on 9 August 2016, the hottest day in Tokyo in 2016. Our case study showed that the energy budget was positively related to the sky view factor, air temperature, and solar radiation. The energy budget was reduced on average by 26–62% in the shade throughout the day.


2018 ◽  
Vol 7 (4.3) ◽  
pp. 383 ◽  
Author(s):  
V. I. Deshko ◽  
N. A. Buyak ◽  
I. O. Sukhodub1

The building is considered together with a heating source in the analysis, it is also proposed to include a human thermal comfort model in this complex system. Regression equations for determining the comfortable room air temperature according to energy and exergy approaches are presented. Human thermal comfort model is included for the first time in the complex building energy system, by determining the comfortable room air temperature, which corresponds to PMV (predicted mean vote), not lower than value for the corresponding building category. The effect of enclosing structures thermal resistance changes on space average radiant temperature and on building category in terms of providing comfortable conditions is estimated. The influence of thermal comfort subjective parameters on primary fuel exergy consumption by the centralized heating system is estimated on the basis of developed model for the Ukrainian conditions.  