scholarly journals Design and Numerical Validation of an Algorithm for the Detumbling and Angular Rate Determination of a CubeSat Using Only Three-Axis Magnetometer Data

2018 ◽  
Vol 2018 ◽  
pp. 1-12 ◽  
Author(s):  
Stefano Carletta ◽  
Paolo Teofilatto

A detumbling algorithm is developed to yield three-axis magnetic stabilization of a CubeSat deployed with unknown RAAN, orbit phase angle, inclination, attitude, and angular rate. Data from a three-axis magnetometer are the only input to determine both the control torque and the angular rate of the spacecraft. The algorithm is designed to produce a magnetic dipole moment which is constantly orthogonal to the geomagnetic field vector, independently of both the attitude and the angular rate of the rigid spacecraft. The angular rates are calculated in real time from magnetometer data, and the use of a second-order low-pass filter allows to rapidly reduce the measurement error within ±0.2 deg/sec. Numerical validation of the algorithm is performed, and a variety of feasible scenarios is simulated assuming the CubeSat to operate in low Earth orbit. The robustness of the algorithm, with respect to unknown deployment conditions, different sampling rates, and uncertainties on the moments of inertia of the CubeSat, is verified.

2017 ◽  
Vol E100.C (10) ◽  
pp. 858-865 ◽  
Author(s):  
Yohei MORISHITA ◽  
Koichi MIZUNO ◽  
Junji SATO ◽  
Koji TAKINAMI ◽  
Kazuaki TAKAHASHI

2016 ◽  
Vol 15 (12) ◽  
pp. 2579-2586
Author(s):  
Adina Racasan ◽  
Calin Munteanu ◽  
Vasile Topa ◽  
Claudia Pacurar ◽  
Claudia Hebedean

Author(s):  
Nanan Chomnak ◽  
Siradanai Srisamranrungrueang ◽  
Natapong Wongprommoon
Keyword(s):  

Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4305
Author(s):  
Takamasa Terada ◽  
Masahiro Toyoura ◽  
Takahide Sato ◽  
Xiaoyang Mao

In this work, we propose a fabric electrode with a special structure that can play the role of a noise reduction filter. Fabric electrodes made of the conductive fabric have been used for long-term ECG measurements because of their flexibility and non-invasiveness; however, due to the large impedance between the skin and the fabric electrodes, noise is easily introduced into the ECG signal. In contrast to conventional work, in which chip-type passive elements are glued to the electrode to reduce noise, the proposed electrode can obtain a noise-reduced ECG by changing the structure of fabric. Specifically, the proposed electrode was folded multiple times to form a capacitor with a capacitance of about 3 nF. It is combined with the skin-electrode impedance to form a low-pass filter. In the experiment, we made a prototype of the electrodes and measured ECG at rest and during EMG-induced exercise. As a result, the SNR values at rest and during exercise were improved about 12.02 and 10.29 , respectively, compared with the fabric electrode without special structure. In conclusion, we have shown that changing the fabric electrode structure effectively removes noise in ECG measurement.


Sign in / Sign up

Export Citation Format

Share Document