scholarly journals Simulation Analysis on Water’s Micro Seepage Laws under Different Pressure Gradients Using Computed Tomography Method

2018 ◽  
Vol 2018 ◽  
pp. 1-26 ◽  
Author(s):  
Gang Zhou ◽  
Lei Qiu ◽  
Wenzheng Zhang ◽  
Jiao Xue

The aim of this paper was to develop a model that can characterize the actual micropore structures in coal and gain an in-depth insight into water’s seepage rules in coal pores under different pressure gradients from a microscopic perspective. To achieve this goal, long-flame coals were first scanned by an X-ray 3D microscope; then, through a representative elementary volume (REV) analysis, the optimal side length was determined to be 60 μm; subsequently, by using Avizo software, the coal’s micropore structures were acquired. Considering that the porosity varies in the same coal sample, this study selected four regions in the sample for an in-depth analysis. Moreover, numerical simulations on water’s seepage behaviors in coal under 30 different pressure gradients were performed. The results show that (1) the variation of the simulated seepage velocity and pressure gradient accorded with Forchheimer’s high-velocity nonlinear seepage rules; (2) the permeability did not necessarily increase with the increase of the effective porosity; (3) in the same model, under different pressure gradients, the average seepage pressure decreased gradually, while the average seepage velocity and average mass flow varied greatly with the increase of the seepage length; and (4) under the same pressure gradient, the increase of the average mass flow from the inlet to the outlet became more significant under a higher inlet pressure.

During transpiration the hydrostatic tension which develops in the xylem conducting elements of the root draws water from the soil through the intervening tissues of the cortex, etc. It is uncertain whether this movement is entirely diffusional or in part a mass flow. To detect any such mass flow tomato plants grown in water culture were decapitated and placed in a canister through the lid of which the cut stem protruded and in which the pressure on the culture medium could be raised. The resulting rate of exudation (flux) was measured, and compared with the flux caused by an equivalent difference in osmotic potential obtained by measuring the ∆ f. p. of the medium and sap exuded. If these values of flux were equal, movement was by diffusion alone, but if pressure caused a greater flux, an additional mass flow was indicated. Preliminary experiments indicated a much greater flux in response to differences of pressure than osmotic potential, but accurate assessment of the effect was precluded by difficulties inherent in this straightforward approach. A less direct technique was therefore devised; the change in flux caused by changing the osmotic potential of the external medium (the hydrostatic pressure being maintained constant) was compared with the change in flux caused by changing the external pressure (the osmotic potential of the external medium being kept constant). The changes in flux were measured in such a way as to minimize changes in the osmotic potential in the xylem and in resistances to diffusion or mass flow respectively. In this way the change in flux per unit change in osmotic potential difference across the cortex (osmotic permeability coefficient, k 0 ) and the change in flux per unit change in pressure difference across the cortex (pressure permeability coefficient, k p ) could be compared under the same pressure gradient and in addition the effects of pressure gradients on k 0 could be studied. Thus, the effects of a pressure gradient on the diffusional movement of water could be assessed, as well as any mass flow component of the flux detected and measured.


Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1158
Author(s):  
Giovanna Cavazzini ◽  
Francesco Giacomel ◽  
Alberto Benato ◽  
Francesco Nascimben ◽  
Guido Ardizzon

Scroll compressors are widely adopted machines in both refrigeration systems and heat pumps. However, their efficiency is basically poor and constitutes the main bottleneck for improving the overall system performance. In fact, due to the complex machine fluid dynamics, scroll design is mainly based on theoretical and/or semi-empirical approaches. Designs strategies that do not guarantee an in-depth analysis of the machine behavior can be supplemented with a Computation Fluid Dynamics (CFD) approach. To this purpose, in the present work, the scroll compressor inner fluid dynamics is numerically analyzed in detail using two CFD software and two different modelling strategies for the axial gap. The analysis of the fluid evolution within the scroll wraps reveals unsteady phenomena developing during the suction and discharge phases, amplified by the axial clearance with negative impact on the main fluid flow (e.g., −13% of average mass flow rate for an axial gap of 30 μ) and on the scroll performance (e.g., +26% of average absorbed power for an axial gap of 30 μ). In terms of accuracy, the k-ε offers good performance on the estimation of average quantities but proves to be inadequate for capturing the complexity of the unsteady phenomena caused by the axial gap (e.g., −19% of the absorbed power in case of perfect tip seal). The need for considering specific geometric details in design procedures is highlighted, and guidelines on the choice of the most suitable numerical model are provided depending on the analysis needs.


2011 ◽  
Vol 301 (1) ◽  
pp. H48-H60 ◽  
Author(s):  
Michael J. Davis ◽  
Elaheh Rahbar ◽  
Anatoliy A. Gashev ◽  
David C. Zawieja ◽  
James E. Moore

Secondary lymphatic valves are essential for minimizing backflow of lymph and are presumed to gate passively according to the instantaneous trans-valve pressure gradient. We hypothesized that valve gating is also modulated by vessel distention, which could alter leaflet stiffness and coaptation. To test this hypothesis, we devised protocols to measure the small pressure gradients required to open or close lymphatic valves and determine if the gradients varied as a function of vessel diameter. Lymphatic vessels were isolated from rat mesentery, cannulated, and pressurized using a servo-control system. Detection of valve leaflet position simultaneously with diameter and intraluminal pressure changes in two-valve segments revealed the detailed temporal relationships between these parameters during the lymphatic contraction cycle. The timing of valve movements was similar to that of cardiac valves, but only when lymphatic vessel afterload was elevated. The pressure gradients required to open or close a valve were determined in one-valve segments during slow, ramp-wise pressure elevation, either from the input or output side of the valve. Tests were conducted over a wide range of baseline pressures (and thus diameters) in passive vessels as well as in vessels with two levels of imposed tone. Surprisingly, the pressure gradient required for valve closure varied >20-fold (0.1–2.2 cmH2O) as a passive vessel progressively distended. Similarly, the pressure gradient required for valve opening varied sixfold with vessel distention. Finally, our functional evidence supports the concept that lymphatic muscle tone exerts an indirect effect on valve gating.


1997 ◽  
Vol 273 (2) ◽  
pp. H997-H1002 ◽  
Author(s):  
R. E. Drake ◽  
S. Dhother ◽  
R. A. Teague ◽  
J. C. Gabel

Microvascular membranes are heteroporous, so the mean osmotic reflection coefficient for a microvascular membrane (sigma d) is a function of the reflection coefficient for each pore. Investigators have derived equations for sigma d based on the assumption that the protein osmotic pressure gradient across the membrane (delta II) does not vary from pore to pore. However, for most microvascular membranes, delta II probably does vary from pore to pore. In this study, we derived a new equation for sigma d. According to our equation, pore-to-pore differences in delta II increase the effect of small pores and decrease the effect of large pores on the overall membrane osmotic reflection coefficient. Thus sigma d for a heteroporous membrane may be much higher than previously derived equations indicate. Furthermore, pore-to-pore delta II differences increase the effect of plasma protein osmotic pressure to oppose microvascular fluid filtration.


1999 ◽  
Vol 122 (1) ◽  
pp. 60-65 ◽  
Author(s):  
A. J. Pierorazio ◽  
A. M. Birk

This paper presents the results of the first full test series of commercial pressure relief valves using the newly constructed Queen’s University/Transport Canada dynamic valve test facility (VTF) in Maitland, Ontario. This facility is unique among those reported in the literature in its ability to cycle the valves repeatedly and to measure the time-varying flow rates during operation. This dynamic testing provides much more insight into valve behavior than the single-pop or continuous flow tests commonly reported. The facility is additionally unique in its simulation of accident conditions as a means of measuring valve performance. Specimen valves for this series represent 20 each of three manufacturers’ design for a semi-internal 1-in. 312 psi LPG relief valve. The purpose of this paper is to present the procedure and results of these tests. No effort is made to perform in-depth analysis into the causes of the various behaviors, nor is any assessment made of the risk presented by any of the valves. [S0094-9930(00)01201-4]


Author(s):  
Frank J. Aldrich

A physics-based approach is employed and a new prediction tool is developed to predict the wavevector-frequency spectrum of the turbulent boundary layer wall pressure fluctuations for subsonic airfoils under the influence of adverse pressure gradients. The prediction tool uses an explicit relationship developed by D. M. Chase, which is based on a fit to zero pressure gradient data. The tool takes into account the boundary layer edge velocity distribution and geometry of the airfoil, including the blade chord and thickness. Comparison to experimental adverse pressure gradient data shows a need for an update to the modeling constants of the Chase model. To optimize the correlation between the predicted turbulent boundary layer wall pressure spectrum and the experimental data, an optimization code (iSIGHT) is employed. This optimization module is used to minimize the absolute value of the difference (in dB) between the predicted values and those measured across the analysis frequency range. An optimized set of modeling constants is derived that provides reasonable agreement with the measurements.


Author(s):  
Farhan Javaid ◽  
Habib Pouriayevali ◽  
Karsten Durst

Abstract To comprehend the mechanical behavior of a polycrystalline material, an in-depth analysis of individual grain boundary (GB) and dislocation interactions is of prime importance. In the past decade, nanoindentation emerged as a powerful tool to study the local mechanical response in the vicinity of the GB. The improved instrumentation and test protocols allow to capture various GB–dislocation interactions during the nanoindentation in the form of strain bursts on the load–displacement curve. Moreover, the interaction of the plastic zone with the GB provides important insight into the dislocation transmission effects of distinct grain boundaries. Of great importance for the analysis and interpretation of the observed effects are microstructural investigations and computational approaches. This review paper focused on recent advances in the dislocation–GB interactions and underlying mechanisms studied via nanoindentation, which includes GB pop-in phenomenon, localized grain movement under ambient conditions, and an analysis of the slip transfer mechanism using theoretical treatments and simulations. Graphical abstract


Author(s):  
Jeffrey P. Bons ◽  
Stephen T. McClain

Experimental measurements of heat transfer (St) are reported for low speed flow over scaled turbine roughness models at three different freestream pressure gradients: adverse, zero (nominally), and favorable. The roughness models were scaled from surface measurements taken on actual, in-service land-based turbine hardware and include samples of fuel deposits, TBC spallation, erosion, and pitting as well as a smooth control surface. All St measurements were made in a developing turbulent boundary layer at the same value of Reynolds number (Rex≅900,000). An integral boundary layer method used to estimate cf for the smooth wall cases allowed the calculation of the Reynolds analogy (2St/cf). Results indicate that for a smooth wall, Reynolds analogy varies appreciably with pressure gradient. Smooth surface heat transfer is considerably less sensitive to pressure gradients than skin friction. For the rough surfaces with adverse pressure gradient, St is less sensitive to roughness than with zero or favorable pressure gradient. Roughness-induced Stanton number increases at zero pressure gradient range from 16–44% (depending on roughness type), while increases with adverse pressure gradient are 7% less on average for the same roughness type. Hot-wire measurements show a corresponding drop in roughness-induced momentum deficit and streamwise turbulent kinetic energy generation in the adverse pressure gradient boundary layer compared with the other pressure gradient conditions. The combined effects of roughness and pressure gradient are different than their individual effects added together. Specifically, for adverse pressure gradient the combined effect on heat transfer is 9% less than that estimated by adding their separate effects. For favorable pressure gradient, the additive estimate is 6% lower than the result with combined effects. Identical measurements on a “simulated” roughness surface composed of cones in an ordered array show a behavior unlike that of the scaled “real” roughness models. St calculations made using a discrete-element roughness model show promising agreement with the experimental data. Predictions and data combine to underline the importance of accounting for pressure gradient and surface roughness effects simultaneously rather than independently for accurate performance calculations in turbines.


2021 ◽  
Author(s):  
Nikolay Baryshnikov ◽  
Evgeniy Zenchenko ◽  
Sergey Turuntaev

<p>Currently, a number of studies showing that the injection of fluid into the formation can cause induced seismicity. Usually, it is associated with a change in the stress-strain state of the reservoir during the pore pressure front propagation. Modeling this process requires knowledge of the features of the filtration properties of reservoir rocks. Many researchers note the fact that the measured permeability of rock samples decreases at low pressure gradients. Among other things, this may be due to the formation of boundary adhesion layers with altered properties at the interfaces between the liquid and solid phases. The characteristic thickness of such layer can be fractions of a micron, and the effect becomes significant when filtering the fluid in rocks with a comparable characteristic pore size. The purpose of this work was to study the filtration properties of rock samples with low permeability at low flow rates. Laboratory modeling of such processes is associated with significant technical difficulties, primarily with the accuracy limit of measuring instruments when approaching zero speed values. The technique used by us to conduct the experiment and data processing allows us to study the dependence of the apparent permeability on the pore pressure gradient in the range of 0.01 MPa/m, which is comparable to the characteristic pressure gradients during the development of oil fields. In the course of the study, we carried out laboratory experiments on limestone core samples, during which the dependencies of their apparent permeability on the pore pressure gradient were obtained. We observed a significant decrease in their permeability at low flow rates. In the course of analyzing the experimental results, we proposed that a decrease in apparent permeability may occur due to the effect of even a small amount of residual gas in the pore space of the samples. This has been confirmed by additional experiments. The possibility of clogging of core sample pore space must be considered when conducting when conducting laboratory studies of the core apparent permeability.</p>


Sign in / Sign up

Export Citation Format

Share Document