scholarly journals Evaluation of Mechanical Properties and Marginal Fit of Crowns Fabricated Using Commercially Pure Titanium and FUS-Invest

2017 ◽  
Vol 2017 ◽  
pp. 1-9 ◽  
Author(s):  
Jinshuang Wu ◽  
Xianli Wang ◽  
Helin Xing ◽  
Tianwen Guo ◽  
Chaofang Dong ◽  
...  

This study investigated the mechanical properties and single crown accuracy of the tailor-made Fourth University Stomatology investment (FUS-invest) for casting titanium. Background. Current investment for casting titanium is not optimal for obtaining high-quality castings, and the commercially available titanium investment is costly. Methods. Titanium specimens were cast using the tailor-made FUS-invest. The mechanical properties were tested using a universal testing machine. Fractured castings were characterized by energy-dispersive spectroscopy. 19 titanium crowns were produced using FUS-invest and another 19 by Symbion. The accuracy of crowns was evaluated. Results. The mechanical properties of the titanium cast by FUS-invest were elastic modulus 125.6 ± 8.8 GPa, yield strength 567.5 ± 11.1 MPa, tensile strength 671.2 ± 15.6 MPa, and elongation 4.6 ± 0.2%. For marginal fit, no significant difference (P>0.05) was found at four marker points of each group. For internal fit, no significant difference (P>0.05) was found between two groups, whereas significant difference (P<0.01) was found at different mark point of each group. Conclusions. The mechanical properties of titanium casted using FUS-invest fulfilled the ISO 9693 criteria. The marginal and internal fit of the titanium crowns using either the FUS-invest or Symbion were similar.

2007 ◽  
Vol 18 (3) ◽  
pp. 225-230 ◽  
Author(s):  
Natércia Carreira Soriani ◽  
Mônica Barbosa Leal ◽  
Silvana Maria Paulino ◽  
Valéria Oliveira Pagnano ◽  
Osvaldo Luiz Bezzon

The goal of this study was to evaluate the effect of using die spacers on the marginal fit of NiCr (M1) and NiCrBe (M2) alloys and commercially pure titanium (cpTi) (M3) copings cast by the lost wax technique. Using a metal matrix, 45 resin added extra hard type IV stone models were obtained for the fabrication of wax patterns under the following conditions: no die spacer (A), with one die spacer layer (B) and with two die spacer layers (C), with five repetitions for each condition (alloy x die). Each die was waxed and the wax patterns were invested as per manufacturer's instructions. Three wax patterns were embedded in each casting ring, each corresponding to one of the conditions. Each coping, seated to the metal matrix by a seating pressure standardizing device (SPSD), was taken to an optical microscope for measurement of marginal discrepancy. The obtained data (µm) were analyzed statistically by ANOVA and Tukey' test (a=5%). There was statistically significant difference (p<0.05) among the materials (M1=110.67; M2=130.33 and M3=148.33). Regarding the use of the die spacer, there was a statistically significant difference (p<0.05) among the three conditions (A=162.00; B=131.06 and C=96.67). It was concluded that there is less marginal discrepancy with two die spacer layers.


2012 ◽  
Vol 13 (4) ◽  
pp. 476-480
Author(s):  
Johnson Campideli Fonseca ◽  
Aloísio Oro Spazzin ◽  
Lucas Zago Naves ◽  
Ana Rosa Costa ◽  
Lourenço Correr-Sobrinho ◽  
...  

ABSTRACT Aim To evaluate the mechanical properties (ultimate tensile strength, elongation and hardness) of the commercially pure titanium (cp Ti) as casting and after ceramic firing cycles. Materials and methods Dumbbell-shaped specimens were prepared for the tensile strength testing. Disk-shaped cast specimens were used for microhardness testing. The ceramic firing cycles were made simulating a low fusion ceramic application. Tensile testing was conducted in a universal testing machine at a crosshead speed of 1 mm/min until failure. Ultimate tensile strength and elongation were recorded. The fracture mode was analyzed by scanning electron microscopy. Vickers hardness was measured in a hardness tester. The data from the tensile and hardness tests were subjected to a one-way analysis of variance and Tukey's test (α = 0.05). Results The mean values of tensile strength were not changed by the ceramic firing cycles. Lower hardness was observed for cp Ti as casting compared with Ti cast after the firing cycles. Clinical significance The ceramic firing cycles did not show any considerable prejudicial effects on the mechanical properties of the cp Ti. How to cite this article Fonseca JC, Spazzin AO, Naves LZ, Costa AR, Correr-Sobrinho L, Henriques GEP. Mechanical Properties of Cast Commercially Pure Titanium Simulating Ceramic Firing Cycles. J Contemp Dent Pract 2012;13(4): 476-480.


2005 ◽  
Vol 19 (2) ◽  
pp. 139-143 ◽  
Author(s):  
Wagner Sotero Fragoso ◽  
Guilherme Elias Pessanha Henriques ◽  
Edwin Fernando Ruiz Contreras ◽  
Marcelo Ferraz Mesquita

Commercially pure titanium (CP Ti) has been widely applied to fabricate cast devices because of its favorable properties. However, the mold temperature recommended for the manufacture of casts has been considered relatively low, causing inadequate castability and poor marginal fit of cast crowns. This study evaluated and compared the influence of mold temperature (430°C - as control, 550°C, 670°C) on the marginal discrepancies of cast CP Ti crowns. Eight bovine teeth were prepared on a mechanical grinding device and impressions were used to duplicate each tooth and produce eight master dies. Twenty-four crowns were fabricated using CP Ti in three different groups of mold temperature (n = 8): 430°C (as control), 550°C and 670°C. The gap between the crown and the bovine tooth was measured at 50 X magnification with a traveling microscope. The marginal fit values of the cast CP Ti crowns were submitted to the Kruskal-Wallis test (p = 0.03). The 550°C group (95.0 µm) showed significantly better marginal fit than the crowns of the 430°C group (203.4 µm) and 670°C group (213.8 µm). Better marginal fit for cast CP Ti crowns was observed with the mold temperature of 550°C, differing from the 430°C recommended by the manufacturer.


2007 ◽  
Vol 35 (10) ◽  
pp. 800-805 ◽  
Author(s):  
Érica Miranda de Torres ◽  
Renata Cristina Silveira Rodrigues ◽  
Maria da Gloria Chiarello de Mattos ◽  
Ricardo Faria Ribeiro

2017 ◽  
Vol 1 (88) ◽  
pp. 5-11 ◽  
Author(s):  
J. Palán ◽  
L. Maleček ◽  
J. Hodek ◽  
M. Zemko ◽  
J. Dzugan

Purpose: At present, materials research in the area of SPD (severe plastic deformation) processes is very intensive. Materials processed by these techniques show better mechanical properties and have finer grain when compared to the input feedstock. The refined microstructure may be ultrafine-grained or nanostructured, where the grain size becomes less than 100 nm. One of the materials used for such processes is CP (commercially pure) titanium of various grades, which is widely used for manufacturing dental implants. The article deals with one of the technologies available for the production of ultrafine-grained titanium: Conform technology. CP titanium processed by CONFORM technology exhibits improved mechanical properties and very favourable biocompatibility, due to its fine-grained structure. The article presents the current experience in the production of ultrafine CP titanium using this technology. The main objective of this article is describing the behaviour of CP titanium during forming in the Conform device and its subsequent use in dental implantology. Design/methodology/approach: In the present study, commercially pure Grade 2 titanium was processed using the CONFORM machine. The numerical simulation of the process was done using FEM method with DEFORMTM software. The evaluation was performed by simple tensile testing and transmission electron microscopy. The first conclusions were derived from the determined mechanical properties and based on analogies in available publications on a similar topic. Findings: This study confirmed that the SPD process improves mechanical properties and does not impair the ductility of the material. The CONFORM process enables the continuous production of ultrafine-grained or nanostructured materials. Research limitations/implications: At the present work, the results show the possible way of continuous production of ultrafine-grained or nanostructured materials. Nevertheless, the further optimization is needed in order to improve the final quality of wires and stabilize the process. As these factors will be solved, the technology will be ready for the industry. Practical implications: The article gives the practical information about the continuous production of ultrafine-grained pure titanium Grade 2 and the possibility of use this material for dental implants. Originality/value: The present paper gives information about the influence of the CONFORM technology on final mechanical and structural properties with the emphasis on technological aspects


2012 ◽  
Vol 23 (5) ◽  
pp. 496-501 ◽  
Author(s):  
Marcelo Bighetti Toniollo ◽  
Rodrigo Galo ◽  
Ana Paula Macedo ◽  
Renata Cristina Silveira Rodrigues ◽  
Ricardo Faria Ribeiro ◽  
...  

The effects of fluoride, which is present in different oral hygiene products, deserve more investigation because little is known about their impact on the surface of titanium, which is largely used in Implantology. This study evaluated the surface of commercially pure titanium (cpTi) after exposure to different concentrations of sodium fluoride (NaF). The hypothesis tested in this study was that different concentrations of NaF applied at different time intervals can affect the titanium surface in different ways. The treatments resulted in the following groups: GA (control): immersion in distilled water; GB: immersion in 0.05% NaF for 3 min daily; GC: immersion in 0.2% NaF for 3 min daily; GD: immersion in 0.05% NaF for 3 min every 2 weeks; and GE: immersion in 0.2% NaF for 3 min every 2 weeks. The experiment lasted 60 days. Roughness was measured initially and every 15 days subsequently up to 60 days. After 60 days, corrosion analysis and anodic polarization were done. The samples were examined by scanning electron microscopy (SEM). The roughness data were analyzed by ANOVA and there was no significant difference among groups and among time intervals. The corrosion data (i corr) were analyzed by the Mann-Whitney test, and significant differences were found between GA and GC, GB and GC, GC and GD, GC and GE. SEM micrographs showed that the titanium surface exposed to NaF presented corrosion that varied with the different concentrations. This study suggests that the use of 0.05% NaF solution on cpTi is safe, whereas the 0.2% NaF solution should be carefully evaluated with regard to its daily use.


Sign in / Sign up

Export Citation Format

Share Document