scholarly journals MEMS Technology Sensors as a More Advantageous Technique for Measuring Foot Plantar Pressure and Balance in Humans

2016 ◽  
Vol 2016 ◽  
pp. 1-9 ◽  
Author(s):  
Clara Sanz Morère ◽  
Łukasz Surażyński ◽  
Ana Rodrigo Pérez-Tabernero ◽  
Erkki Vihriälä ◽  
Teemu Myllylä

Locomotor activities are part and parcel of daily human life. During walking or running, feet are subjected to high plantar pressure, leading sometimes to limb problems, pain, or foot ulceration. A current objective in foot plantar pressure measurements is developing sensors that are small in size, lightweight, and energy efficient, while enabling high mobility, particularly for wearable applications. Moreover, improvements in spatial resolution, accuracy, and sensitivity are of interest. Sensors with improved sensing techniques can be applied to a variety of research problems: diagnosing limb problems, footwear design, or injury prevention. This paper reviews commercially available sensors used in foot plantar pressure measurements and proposes the utilization of pressure sensors based on the MEMS (microelectromechanical systems) technique. Pressure sensors based on this technique have the capacity to measure pressure with high accuracy and linearity up to high pressure levels. Moreover, being small in size, they are highly suitable for this type of measurement. We present two MEMS sensor models and study their suitability for the intended purpose by performing several experiments. Preliminary results indicate that the sensors are indeed suitable for measuring foot plantar pressure. Importantly, by measuring pressure continuously, they can also be utilized for body balance measurements.

2001 ◽  
Author(s):  
Emily J. Pryputniewicz ◽  
John P. Angelosanto ◽  
Gordon C. Brown ◽  
Cosme Furlong ◽  
Ryszard J. Pryputniewicz

Abstract Using recent advances in microelectromechanical systems (MEMS) technology, a new multivariable sensor was developed. This MEMS sensor, capable of measuring temperature, absolute pressure, and differential pressure on a single chip, is particularly suitable for applications in process control industry. However, functional operation of the sensor depends on validation of its performance under specific test conditions. We have developed a hybrid methodology, based on analysis and measurements, that allows such validation. In this paper, the MEMS multivariable sensor is described, the hybrid methodology is outlined, and its use is illustrated with representative results.


Sensors ◽  
2019 ◽  
Vol 19 (13) ◽  
pp. 2908 ◽  
Author(s):  
Yongzhao Xu ◽  
Xiduo Hu ◽  
Sudip Kundu ◽  
Anindya Nag ◽  
Nasrin Afsarimanesh ◽  
...  

The paper highlights some of the significant works done in the field of medical and biomedical sensing using silicon-based technology. The use of silicon sensors is one of the pivotal and prolonged techniques employed in a range of healthcare, industrial and environmental applications by virtue of its distinct advantages over other counterparts in Microelectromechanical systems (MEMS) technology. Among them, the sensors for biomedical applications are one of the most significant ones, which not only assist in improving the quality of human life but also help in the field of microfabrication by imparting knowledge about how to develop enhanced multifunctional sensing prototypes. The paper emphasises the use of silicon, in different forms, to fabricate electrodes and substrates for the sensors that are to be used for biomedical sensing. The electrical conductivity and the mechanical flexibility of silicon vary to a large extent depending on its use in developing prototypes. The article also explains some of the bottlenecks that need to be dealt with in the current scenario, along with some possible remedies. Finally, a brief market survey is given to estimate a probable increase in the usage of silicon in developing a variety of biomedical prototypes in the upcoming years.


2014 ◽  
Vol 8 (1) ◽  
pp. 84-92 ◽  
Author(s):  
Hussein Abou Ghaida ◽  
Serge Mottet ◽  
Jean-Marc Goujon

In order to monitor pressure under feet, this study presents a biomechanical model of the human foot. The main elements of the foot that induce the plantar pressure distribution are described. Then the link between the forces applied at the ankle and the distribution of the plantar pressure is established. Assumptions are made by defining the concepts of a 3D internal foot shape, which can be extracted from the plantar pressure measurements, and a uniform elastic medium, which describes the soft tissues behaviour. In a second part, we show that just 3 discrete pressure sensors per foot are enough to generate real time plantar pressure cartographies in the standing position or during walking. Finally, the generated cartographies are compared with pressure cartographies issued from the F-SCAN system. The results show 0.01 daN (2% of full scale) average error, in the standing position.


Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 2246
Author(s):  
Scott Pardoel ◽  
Gaurav Shalin ◽  
Julie Nantel ◽  
Edward D. Lemaire ◽  
Jonathan Kofman

Freezing of gait (FOG) is a sudden and highly disruptive gait dysfunction that appears in mid to late-stage Parkinson’s disease (PD) and can lead to falling and injury. A system that predicts freezing before it occurs or detects freezing immediately after onset would generate an opportunity for FOG prevention or mitigation and thus enhance safe mobility and quality of life. This research used accelerometer, gyroscope, and plantar pressure sensors to extract 861 features from walking data collected from 11 people with FOG. Minimum-redundancy maximum-relevance and Relief-F feature selection were performed prior to training boosted ensembles of decision trees. The binary classification models identified Total-FOG or No FOG states, wherein the Total-FOG class included data windows from 2 s before the FOG onset until the end of the FOG episode. Three feature sets were compared: plantar pressure, inertial measurement unit (IMU), and both plantar pressure and IMU features. The plantar-pressure-only model had the greatest sensitivity and the IMU-only model had the greatest specificity. The best overall model used the combination of plantar pressure and IMU features, achieving 76.4% sensitivity and 86.2% specificity. Next, the Total-FOG class components were evaluated individually (i.e., Pre-FOG windows, Freeze windows, transition windows between Pre-FOG and Freeze). The best model detected windows that contained both Pre-FOG and FOG data with 85.2% sensitivity, which is equivalent to detecting FOG less than 1 s after the freeze began. Windows of FOG data were detected with 93.4% sensitivity. The IMU and plantar pressure feature-based model slightly outperformed models that used data from a single sensor type. The model achieved early detection by identifying the transition from Pre-FOG to FOG while maintaining excellent FOG detection performance (93.4% sensitivity). Therefore, if used as part of an intelligent, real-time FOG identification and cueing system, even if the Pre-FOG state were missed, the model would perform well as a freeze detection and cueing system that could improve the mobility and independence of people with PD during their daily activities.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1450
Author(s):  
Alfredo Ciniglio ◽  
Annamaria Guiotto ◽  
Fabiola Spolaor ◽  
Zimi Sawacha

The quantification of plantar pressure distribution is widely done in the diagnosis of lower limbs deformities, gait analysis, footwear design, and sport applications. To date, a number of pressure insole layouts have been proposed, with different configurations according to their applications. The goal of this study is to assess the validity of a 16-sensors (1.5 × 1.5 cm) pressure insole to detect plantar pressure distribution during different tasks in the clinic and sport domains. The data of 39 healthy adults, acquired with a Pedar-X® system (Novel GmbH, Munich, Germany) during walking, weight lifting, and drop landing, were used to simulate the insole. The sensors were distributed by considering the location of the peak pressure on all trials: 4 on the hindfoot, 3 on the midfoot, and 9 on the forefoot. The following variables were computed with both systems and compared by estimating the Root Mean Square Error (RMSE): Peak/Mean Pressure, Ground Reaction Force (GRF), Center of Pressure (COP), the distance between COP and the origin, the Contact Area. The lowest (0.61%) and highest (82.4%) RMSE values were detected during gait on the medial-lateral COP and the GRF, respectively. This approach could be used for testing different layouts on various applications prior to production.


Author(s):  
J-B Li ◽  
K Jiang ◽  
G J Davies

A novel die-sinking micro-electro discharge machining (EDM) process is presented for volume fabrication of metallic microcomponents. In the process, a high-precision silicon electrode is fabricated using deep reactive ion etching (DRIE) process of microelectromechanical systems (MEMS) technology and then coated with a thin layer of copper to increase the conductivity. The metalized Si electrode is used in the EDM process to manufacture metallic microcomponents by imprinting the electrode onto a flat metallic surface. The two main advantages of this process are that it enables the fabrication of metallic microdevices and reduces manufacturing cost and time. The development of the new EDM process is described. A silicon component was produced using the Surface Technology Systems plasma etcher and the DRIE process. Such components can be manufactured with a precision in nanometres. The minimum feature of the component is 50 μm. In the experiments, the Si component was coated with copper and then used as the electrode on an EDM machine of 1 μm resolution. In the manufacturing process, 130 V and 0.2 A currents were used for a period of 5 min. The SEM images of the resulting device show clear etched areas, and the electric discharge wave chart indicates a good fabrication condition. The experimental results have been analysed and the new micro-EDM process is found to be able to fabricate 25 μm features.


2011 ◽  
Vol 39 (12) ◽  
pp. 2679-2685 ◽  
Author(s):  
Rebecca S. Kearney ◽  
Sarah E. Lamb ◽  
Juul Achten ◽  
Nicholas R. Parsons ◽  
Matthew L. Costa

Background: Advances in the management of Achilles tendon rupture have led to the development of immediate weightbearing protocols. These vary regarding which ankle-foot orthoses (AFOs) are used and the number of inserted heel wedges used within them. Purpose: This study was conducted to evaluate plantar pressure measurements and temporal gait parameters within different AFOs, using different numbers of heel wedges. Study Design: Controlled laboratory study. Methods: Fifteen healthy participants were evaluated using 3 different AFOs, with 4 different levels of inserted heel wedges. Therefore, a total of 12 conditions were evaluated, in a sequence that was randomly allocated to each participant. Pressure and temporal gait parameters were measured using an in-shoe F-Scan pressure system, and range of movement was measured using an electrogoniometer. Results: Ankle-foot orthoses that were restrictive in design, combined with a higher number of inserted heel wedges, reduced forefoot pressures, increased heel pressures, and decreased the amount of time spent in the terminal stance and preswing phase of the gait cycle ( P = .029, .002, and .001). Conclusion: The choice of AFO design and the number of inserted heel wedges have a significant effect on plantar pressure measurements and temporal gait parameters. The implications of these changes need to be applied to the clinical management of acute Achilles tendon ruptures. This clinical management requires a balance between protected weightbearing and functional loading, requiring further research within a clinical context. Clinical Relevance: The biomechanical data from this research imply that a carbon-fiber AFO, with 1 heel raise, protects against excessive dorsiflexion while facilitating the restoration of near-normal gait parameters. This could lead to an accelerated return to function, avoiding the effects of disuse atrophy. This is in contrast to the rigid rocker-bottom AFO design with a greater number of heel-wedge inserts. However, research within a clinical context would be required to ascertain if these biomechanical advantages translate into a functional benefit for patients. The results should also be considered in relation to the amount of force a healing Achilles tendon can withstand.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Eung Tae Kim ◽  
Sungmin Kim

AbstractA smart insole system consisting of pressure sensors, wireless communication modules, and pressure monitoring software has been developed to measure plantar pressure distribution that appears in sewing process. This system calculates the cycle time of each operation by analyzing the real-time plantar pressure data. The operation cycle time was divided into the time done by machine and by manual and calculated by adding the two types of time. By analyzing the cycle time, it is possible to estimate the type of operation a worker is performing. The ability to calculate accurate cycle time and to manage a large volume of data is the advantage of this system. Establishing an accurate cycle time of all operations would be of great help in improving the production process, capacity planning, line efficiency, and labor cost calculation. The system is expected to be a good alternative to the conventional manual measurement process. It will also be able to meet the high demand from garment manufacturers for automated monitoring systems.


2012 ◽  
Vol 81 ◽  
pp. 65-74 ◽  
Author(s):  
Jacopo Iannacci ◽  
Giuseppe Resta ◽  
Paola Farinelli ◽  
Roberto Sorrentino

MEMS (MicroElectroMechanical-Systems) technology applied to the field of Radio Frequency systems (i.e. RF-MEMS) has emerged in the last 10-15 years as a valuable and viable solution to manufacture low-cost and very high-performance passive components, like variable capacitors, inductors and micro-relays, as well as complex networks, like tunable filters, reconfigurable impedance matching networks and phase shifters, and so on. The availability of such components and their integration within RF systems (e.g. radio transceivers, radars, satellites, etc.) enables boosting the characteristics and performance of telecommunication systems, addressing for instance a significant increase of their reconfigurability. The benefits resulting from the employment of RF-MEMS technology are paramount, being some of them the reduction of hardware redundancy and power consumption, along with the operability of the same RF system according to multiple standards. After framing more in detail the whole context of RF MEMS technology, this paper will provide a brief introduction on a typical RF-MEMS technology platform. Subsequently, some relevant examples of lumped RF MEMS passive elements and complex reconfigurable networks will be reported along with their measured RF performance and characteristics.


Sign in / Sign up

Export Citation Format

Share Document