scholarly journals The Impact of Noise Models on Capacity Performance of Distribution Broadband over Power Lines Networks

2016 ◽  
Vol 2016 ◽  
pp. 1-14 ◽  
Author(s):  
Athanasios G. Lazaropoulos

This paper considers broadband potential of distribution Broadband over Power Lines (BPL) networks when different well-known noise models of the BPL literature are applied. The contribution of this paper is twofold. First, the seven most representative and used noise models of the BPL literature are synopsized in this paper. With reference to this set, the broadband performance of a great number of distribution BPL topologies either Overhead (OV) or Underground (UN), either Medium-Voltage (MV) or Low-Voltage (LV), is investigated in terms of suitable capacity metrics. Second, based on the proposed capacity metrics, a comparative capacity analysis is performed among various well-validated noise models. Through the careful study of its results, it is demonstrated that during capacity computations of distribution BPL networks, the flat Additive White Gaussian Noise (FL noise model) can be comfortably assumed as an efficient noise model either in 3–30 MHz or in 3–88 MHz frequency range since its capacity differences with the other well-proven noise models are negligible.

2013 ◽  
Vol 2013 ◽  
pp. 1-19 ◽  
Author(s):  
Athanasios G. Lazaropoulos

This paper reviews and analyzes the broadband capacity and the coexistence potential of overhead and underground medium-voltage/broadband over power lines (MV/BPL) and low-voltage/broadband over power lines (LV/BPL) topologies when one and two repeaters are additively deployed between their existing transmitting and receiving ends (overhead and underground MV/BPL and LV/BPL topologies with two- and three-hop repeater system, respectively). The contribution of this paper is four fold. First, the factors that influence the broadband capacity performance of overhead and underground MV/BPL and LV/BPL topologies with multihop repeater systems are identified, namely the number of repeaters, the distribution power grid type—either overhead or underground, either MV or LV, the initial distribution BPL topology, the multiconductor transmission line configuration, and coupling scheme applied. Second, the well-validated applicability of two-hop repeater systems is now extended in overhead and underground LV/BPL and MV/BPL networks. The significant mitigating role of two-hop repeater systems against capacity losses due to aggravated topologies or different coupling schemes is verified. Third, the deployment upgrade of two- to three-hop repeater systems in distribution BPL topologies is first examined in terms of broadband capacity performance. To study the occurred capacity improvement, suitable capacity contour plots are first proposed. Fourth, multi-hop repeater systems are identified as valuable technology solution so that the required intraoperability between overhead and underground MV/BPL and LV/BPL networks, which is a prerequisite condition before BPL systems symbiosis with other broadband technologies (interoperability), is promoted.


2013 ◽  
Vol 2013 ◽  
pp. 1-30 ◽  
Author(s):  
Athanasios G. Lazaropoulos

This review paper reveals the broadband potential of overhead and underground low-voltage (LV) and medium-voltage (MV) broadband over power lines (BPL) networks associated with multiple-input multiple-output (MIMO) technology. The contribution of this review paper is fourfold. First, the unified value decomposition (UVD) modal analysis is introduced. UVD modal analysis is a new technique that unifies eigenvalue decomposition (EVD) and singular value decomposition (SVD) modal analyses achieving the common handling of traditional SISO/BPL and upcoming MIMO/BPL systems. The validity of UVD modal analysis is examined by comparing its simulation results with those of other exact analytical models. Second, based on the proposed UVD modal analysis, the MIMO channels of overhead and underground LV and MV BPL networks (distribution BPL networks) are investigated with regard to their inherent characteristics. Towards that direction, an extended collection of well-validated metrics from the communications literature, such as channel attenuation, average channel gain (ACG), root-mean-square delay spread (RMS-DS), coherence bandwidth (CB), cumulative capacity, capacity complementary cumulative distribution function (CCDF), and capacity gain (GC), is first applied in overhead and underground MIMO/LV and MIMO/MV BPL channels and systems. It is found that the results of the aforementioned metrics portfolio depend drastically on the frequency, the power grid type (either overhead or underground, either LV or MV), the MIMO scheme configuration properties, the MTL configuration, the physical properties of the cables used, the end-to-end distance, and the number, the electrical length, and the terminations of the branches encountered along the end-to-end BPL signal propagation. Third, three interesting findings concerning the statistical properties of MIMO channels of distribution BPL networks are demonstrated, namely, (i) the ACG, RMS-DS, and cumulative capacity lognormal distributions; (ii) the correlation between RMS-DS and ACG; and (iii) the correlation between RMS-DS and CB. By fitting the numerical results, unified regression distributions appropriate for MIMO/BPL channels and systems are proposed. These three fundamental properties can play significant role in the evaluation of recently proposed statistical channel models for various BPL systems. Fourth, the potential of transformation of overhead and underground LV/BPL and MV/BPL distribution grids to an alternative solution to fiber-to-the-building (FTTB) technology is first revealed. By examining the capacity characteristics of various MIMO scheme configurations and by comparing these capacity results against SISO ones, a new promising urban backbone network seems to be born in a smart grid (SG) environment.


2010 ◽  
Vol 108-111 ◽  
pp. 771-776
Author(s):  
Nan Tian Huang ◽  
Xiao Sheng Liu ◽  
Dian Guo Xu

The power line communication (PLC) channel has been a transmission medium that enables to transfer high-speed digital data through the classical electrical wires. Channel characteristics of power lines are very important for communications systems design. In order to get the suitable model for power line communications analysis and improve the PLC communication quality, researchers do lots of study about the PLC channel characterizations based on actual measurement and theoretical analysis. This paper reviews the conclusions of recent studies, summaries the characteristics of PLC channel for medium voltage power lines and low voltage power lines. The further research is also put forward.


2016 ◽  
Vol 2016 ◽  
pp. 1-24 ◽  
Author(s):  
Athanasios G. Lazaropoulos

This paper investigates the efficiency and accuracy of the best L1 piecewise monotonic data approximation (best L1PMA) in order either to approximate the transfer functions of distribution BPL networks or to reveal the aforementioned transfer functions when various faults occur during their determination. The contribution of this paper is quadruple. First, based on the inherent piecewise monotonicity of distribution BPL transfer functions, a piecewise monotonic data approximation is first applied in BPL networks; best L1PMA is outlined and applied during the determination of distribution BPL transfer functions. Second, suitable performance metrics such as the percent error sum (PES) and fault PES are reported and applied so as to assess the efficiency and accuracy of the best L1PMA during the determination of distribution BPL transfer functions. Third, the factors of distribution BPL networks that influence the performance of best L1PMA are identified. Fourth, the accuracy of the best L1PMA is assessed with respect to its inherent properties, namely, the assumed number of monotonic sections and the nature of faults, that is, faults that follow either continuous uniform distribution (CUD) or normal distribution (ND), during the determination of distribution BPL transfer functions. Finally, best L1PMA may operate as the necessary intermediate antifault method for the theoretical and practical transfer function determination of distribution BPL networks.


2020 ◽  
Author(s):  
Evangelos Pompodakis

<p><b>Conventional power flow (CPF) algorithms assume that the network resistances and reactances remain constant regardless of the weather and loading conditions. Although the impact of the weather in power flow analysis has been recently investigated via the weather-dependent power flow (WDPF) approaches, the magnetic effects in the core of ACSR conductors have not been explicitly considered. ACSR conductors are widely used in distribution networks. Therefore, this manuscript proposes a three-phase weather-dependent power flow algorithm for 4-wire multi-grounded unbalanced microgrids (MGs), which takes into consideration the impact of weather as well as the magnetic effects in the core of ACSR conductors. It is shown that the magnetic effects in the core can significantly influence the power flow results, especially for networks composed of single-layer ACSR conductors. Furthermore, the proposed algorithm explicitly considers the multi-grounded neutral conductor, thus it can precisely simulate unbalanced low voltage (LV) and medium voltage (MV) networks. In addition, the proposed approach is generic and can be applied in both grid-connected and islanded networks. Simulations conducted in a 25-Bus unbalanced LV microgrid highlight the accuracy and benefit of the proposed approach. </b></p>


2020 ◽  
Author(s):  
Evangelos Pompodakis

<p><b>Conventional power flow (CPF) algorithms assume that the network resistances and reactances remain constant regardless of the weather and loading conditions. Although the impact of the weather in power flow analysis has been recently investigated via the weather-dependent power flow (WDPF) approaches, the magnetic effects in the core of ACSR conductors have not been explicitly considered. ACSR conductors are widely used in distribution networks. Therefore, this manuscript proposes a three-phase weather-dependent power flow algorithm for 4-wire multi-grounded unbalanced microgrids (MGs), which takes into consideration the impact of weather as well as the magnetic effects in the core of ACSR conductors. It is shown that the magnetic effects in the core can significantly influence the power flow results, especially for networks composed of single-layer ACSR conductors. Furthermore, the proposed algorithm explicitly considers the multi-grounded neutral conductor, thus it can precisely simulate unbalanced low voltage (LV) and medium voltage (MV) networks. In addition, the proposed approach is generic and can be applied in both grid-connected and islanded networks. Simulations conducted in a 25-Bus unbalanced LV microgrid highlight the accuracy and benefit of the proposed approach. </b></p>


Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1093
Author(s):  
Shimi Sudha Letha ◽  
Angela Espin Delgado ◽  
Sarah K. Rönnberg ◽  
Math H. J. Bollen

Power converters with high switching frequency used to integrate renewable power sources to medium and low voltage networks are sources of emission in the supraharmonic range (2 to 150 kHz). When such converters are connected to a medium voltage (MV) network these supraharmonics propagate through the MV network and can impact network and customer equipment over a wide range. This paper evaluates an existing Swedish MV electrical network and studies the pattern of supraharmonic resonance and the propagation of supraharmonics. The MV network consists of eight feeders including a small wind farm. Simulations reveal that, the bigger the MV network, the more resonant frequencies, but also the lower the amplitude of the resonance peaks in the driving point impedance. It was also identified that for short feeders as length increases, the magnitude of the transfer impedance at supraharmonic frequency decreases. For further increment in feeder length, the magnitude increases or becomes almost constant. For very long feeders, the transfer impedance further starts decreasing. The eight feeders in the network under study are similar but show completely different impedance versus frequency characteristics. Measurements at the MV side of the wind farm show time varying emissions in the supraharmonic range during low power production. The impact of these emissions coupled with system resonance is examined.


2015 ◽  
pp. 64-74 ◽  
Author(s):  
Mark V. Pestov ◽  
◽  
Fedor A. Saraev ◽  
Vladimir A. Terentiev ◽  
Zhaskairat E. Nurmuhambetov ◽  
...  

2020 ◽  
Author(s):  
Evangelos Pompodakis

<p><b>Conventional power flow (CPF) algorithms assume that the network resistances and reactances remain constant regardless of the weather and loading conditions. Although the impact of the weather in power flow analysis has been recently investigated via the weather-dependent power flow (WDPF) approaches, the magnetic effects in the core of ACSR conductors have not been explicitly considered. ACSR conductors are widely used in distribution networks. Therefore, this manuscript proposes a three-phase weather-dependent power flow algorithm for 4-wire multi-grounded unbalanced microgrids (MGs), which takes into consideration the impact of weather as well as the magnetic effects in the core of ACSR conductors. It is shown that the magnetic effects in the core can significantly influence the power flow results, especially for networks composed of single-layer ACSR conductors. Furthermore, the proposed algorithm explicitly considers the multi-grounded neutral conductor, thus it can precisely simulate unbalanced low voltage (LV) and medium voltage (MV) networks. In addition, the proposed approach is generic and can be applied in both grid-connected and islanded networks. Simulations conducted in a 25-Bus unbalanced LV microgrid highlight the accuracy and benefit of the proposed approach. </b></p>