scholarly journals Assessment of Root Canal Enlargement Using Mtwo and BioRace Rotary Files

2015 ◽  
Vol 2015 ◽  
pp. 1-4
Author(s):  
Enzo Cumbo ◽  
Riccardo Russo ◽  
Giuseppe Gallina

Objective. To evaluate root canal enlargement following mechanical shaping using 2 nickel titanium rotary systems.Material and Methods. Forty single-rooted teeth were immersed in resin and sectioned perpendicular to the long axis at 4, 8, and 12 mm from the apex. Digital capture of sections was performed before and after canal instrumentation using Mtwo and BioRace instruments. The area increase of endodontic space was calculated by subtraction.Results. The use of both instruments has allowed the removal of great amounts of dentin from the canal walls, even when the endodontic morphology is characterized by awkwardness to reach recesses.Conclusions. Both procedures seem to be valid and no differences were found between Mtwo and BioRaCe considering the amount of dentin removed at different distances from the apex.

2021 ◽  
Vol 38 (3) ◽  
pp. 291-298
Author(s):  
Nenad Stošić ◽  
Jelena Popović ◽  
Marija Anđelković-Apostolović ◽  
Aleksandar Mitić ◽  
Marija Nikolić ◽  
...  

One of the primary goals in endodontics is efficient cleaning and shaping of the root canal while maintaining its original configuration. Numerous studies highlight the advantage of using nickel-titanium instruments and the most important is their high flexibility and the ability to penetrate the curved canals. The aim of this study was to analyze the ultrastructure of the surface of nickel-titanium endodontic files before and after use. Eighty-four instruments were included in this study. The instruments were used one, three and six times for root canal preparation on extracted upper premolars. The analysis was performed based on the number of uses and the size of the instruments. Changes on flat surfaces in the grooves of the instruments, defects of the cutting edges and fractures were evaluated. The surface ultrastructure was analyzed on a scanning electron microscope (SEM). SEM analysis showed irregularities on the surfaces of the new instruments. Surface defects and damage of the cutting edges were present after the first use. After three uses, the damage was more evident in instruments of all sizes. After six uses, all instruments showed damage of the cutting edges, and a significant number of fractures were observed. Irregularities on the working parts are already noticed on the new endodontic instruments and originate from the production process. The first signs of damage appear after the first use. In order to prevent errors in clinical work during root canal preparation, it is recommended that the number of instruments uses should be limited.


2014 ◽  
Vol 15 (2) ◽  
pp. 174-180 ◽  
Author(s):  
Dina Al-Sudani ◽  
Majed Almalki ◽  
Saad Al-Shahrani ◽  
Michael Ahlquist

ABSTRACT Aim The present study was conducted with the aim of evaluating and comparing the shaping ability of two Nickel-titanium rotary instruments, with two disparate design features, on root canal geometry of extracted human maxillary first premolars using microcomputed tomography. Study design Twenty four bifurcated maxillary first premolars were divided into two groups and embedded in a rubber-based impression material. Both groups were submitted to microcomputed tomography before and after canal preparation (buccal and palatal) with either ProFile Vortex or Revo-S rotary instruments. Images were reconstructed and cross-sections corresponding to a distance 1, 2, 3, 4, 5, 6, and 7 mm from the anatomical apex were selected for canal transportation analysis. Volume changes were also measured. Results The degree and direction of canal transportation were non-significant for both instruments. Statistically significant differences were observed only between levels in the buccal canal in both groups. There was no significant difference between the two rotary systems in regards to the volume of dentin removed. Conclusion Our findings showed that ProFile Vortex and Revo-S instruments respected the original root canal anatomy and behaved similarly. ProFile Vortex rotary systems produced with innovative process were concluded to shape the upper maxillary premolar by leading minimal canal transportation, similar to Revo-S, rotary systems produced from traditional process. How to cite this article Al-Sudani D, Almalki M, Al-Shahrani S, Ahlquist M. Geometric Analysis of Maxillary First Premolar Prepared by Two Nickel-Titanium Rotary Instruments. J Contemp Dent Pract 2014;15(2):174-180.


2018 ◽  
Vol 47 (1) ◽  
pp. 325-334 ◽  
Author(s):  
Zhuwei Huang ◽  
Jingjing Quan ◽  
Jia Liu ◽  
Wen Zhang ◽  
Xiaolei Zhang ◽  
...  

Objective To evaluate the shaping ability of three thermally-treated rotary nickel-titanium (NiTi) systems including ProTaper Next (PTN), HyFlex™ CM (HFCM) and HyFlex™ EDM (HFEDM) during root canal preparation in simulated root canals. Methods A total of 45 simulated root canals were divided into three groups ( n = 15) and prepared with PTN, HFCM or HFEDM files up to size 25. Microcomputed tomography (microCT) was used to scan the specimens before and after instrumentation. Volume and diameter changes, transportations and centring ratios at 11 levels of the simulated root canals were measured and compared. Results HFEDM caused significantly greater volume increases than HFCM and PTN in the entire root canal and in the apical and middle thirds. HFCM removed the least amount of resin in the coronal third compared with HFEDM and PTN. Overall, HFCM caused significantly less transportation in the apical 2 mm and was better centred than PTN in the apical 3 mm. Conclusion Under the conditions of this study, all systems prepared curved canals without significant shaping errors and instrument fracture. PTN and HFCM cut less resin than HFEDM. HFCM stayed centred apically and cut the least material coronally.


2018 ◽  
Vol 12 (1) ◽  
pp. 32-45 ◽  
Author(s):  
Iussif Mamede-Neto ◽  
Álvaro Henrique Borges ◽  
Ana Helena Gonçalves Alencar ◽  
Marco Antonio Hungaro Duarte ◽  
Manoel Damião Sousa Neto ◽  
...  

Objective: To evaluate transportation (T) and centering ability (CA) of root canal preparations using continuous or reciprocating nickel-titanium endodontic files. Materials and Methods: Ninety-six mesiobuccal root canals of mandibular first and second molars were randomly divided into 6 groups (n=16) according to the rotary file used: 1. ProTaper Next; 2. ProTaper Gold; 3. Mtwo; 4. BioRaCe; 5. WaveOne Gold; 6. Reciproc. Root canals were prepared according to manufacturer’s instructions. Cone beam computed tomography scans were obtained before and after root canal preparation. Measurements were made at six different reference points: 2, 3 and 4 mm from the apex and 2, 3 and 4 mm below furcation in different directions. Results: The greatest Mesiodistal (MD) Transportation (T) was found for Reciproc files (p<0.05), and the greatest buccolingual (BL) T, for Reciproc, ProTaper Gold and ProTaper Next files (p<0.05). The greatest Mesiodistal (MD) Centering Ability (CA) was found for BioRaCe files (p<0.05), and the greatest Buccolingual (BL) CA, for BioRaCe and Mtwo files (p<0.05). Conclusion: All systems produced root canal transportation. No file system achieved perfect CA of root preparation. Reciproc files had the greatest MD T and BL T. BioRaCe files had the greatest MD CA, whereas BL CA was similar for BioRaCe and Mtwo files.


Metals ◽  
2020 ◽  
Vol 10 (2) ◽  
pp. 172 ◽  
Author(s):  
Saulius Drukteinis ◽  
Vytaute Peciuliene ◽  
Ruta Bendinskaite ◽  
Vilma Brukiene ◽  
Rasmute Maneliene ◽  
...  

The aim of this study was to investigate the shaping ability and cyclic fatigue resistance of Genius (GN) and WaveOne (WO) nickel-titanium (NiTi) instruments. Forty mesial root canals of mandibular molars were randomly divided into two groups, according to the instrument system used for root canal preparation (n = 20): GN and WO. Root canals were prepared to the full working length using the crown-down technique, with up to 40.04 instruments for GN group and 40.08 instruments for WO group. Specimens were scanned with a µCT before and after instrumentation. The changes in 3D parameters and degree of canal transportation were evaluated in the apical, middle and coronal thirds of root canals. Size 25, taper 0.04 (GN) and 0.08 (WO) instruments (n = 20) were used in simulated root canals until fracturing, and the number of cycles to failure (NCF) was recorded. The fractured files were investigated under a scanning electron microscope to characterize fractured surfaces. Data were analyzed using ANOVA post hoc Tuckey’s tests with the significance level set at 5%. The GN system was able to prepare the higher percentage of the canal surface with less canal transportation in all root canal thirds and displayed the higher resistance to cyclic fatigue in comparison to WO instruments (p < 0.05). However, the length of the fractured segments was not significantly different among the groups; meanwhile, SEM investigations revealed the typical topographic characteristics of fractured surfaces. Hybrid GN instruments demonstrated superior shaping ability and resistance to cyclic fatigue. However, both NiTi instrument systems prepared the root canals with no significant shaping errors, considerable changes in 3D parameters and no significant differences in the topographic appearances of the instrument surfaces after fractures.


2014 ◽  
Vol 25 (3) ◽  
pp. 232-236 ◽  
Author(s):  
Maria Antonieta Veloso Carvalho de Oliveira ◽  
Jessyca Figueira Venâncio ◽  
Analice Giovani Pereira ◽  
Luís Henrique Araújo Raposo ◽  
João Carlos Gabrielli Biffi

The aim of this study was to evaluate the root canal anatomy of mandibular incisors before and after endodontic instrumentation, identifying regions inaccessible to the action of files (Critical instrumentation Area - CA) in a three-dimensional perspective. Thirty human mandibular central incisors were selected, assigned to two groups (n=15) and instrumented using ProTaper Universal rotary files. In the RX group, longitudinal digital radiographic images were obtained in the buccolingual (BL) and mesiodistal (MD) views. In the CT group, cross-sectional micro-computed tomography (µCT) images were obtained at 3, 9 and 15 mm from the apex. The canal area of the specimens was evaluated before and after instrumentation using digital images from each group. Data were analyzed using t-test, one-way ANOVA with subdivided parcels and Tukey's test (α=0.05). The canal area found in the MD radiographs was larger than in the BL radiographs, which was also confirmed in the transversal images (p<0.01). The CA was only detected in the MD radiographs and µCT scans. On the root canal configuration, a continuous reduction in the canal conicity was observed in BL radiographs, while in MD view there was a constriction at the cervical third and subsequent increase at the middle third (p<0.01). The conical shape of the root canal was observed only in the BL view. The canal enlargement in BL radiographs was not indicative of homogeneous instrumentation, since unprepared areas (CA) were also verified on the buccal and lingual walls in different images


2018 ◽  
Vol 46 (6) ◽  
pp. 2219-2229 ◽  
Author(s):  
Ke Xu ◽  
Juan Wang ◽  
Ke Wang ◽  
Nan Gen ◽  
Jin Li

Objective This study was performed to compare the removal efficacy of hard-tissue debris in mandibular first molars prepared to various apical sizes. Methods The mesial root canals of 40 extracted mandibular first molars were prepared by rotary nickel-titanium files to an apical size of #25/0.04 (Group #2504), #30/0.04 (Group #3004), #35/0.04 (Group #3504), and #40/0.04 (Group #4004). Irrigation was performed with 5.25% NaOCl and 17% EDTA. Micro-computed tomography was used to scan the samples before and after root canal preparation. Remnant hard-tissue debris was identified, quantified, and visualized three-dimensionally using shape recognition and image superimposition analysis, and the debris was mapped to its location. Results After preparation, 11.67%±2.99% of the root canals contained hard-tissue debris in Group #2504, 8.00%±2.71% in Group #3004, 7.17%±2.88% in Group #3504, and 4.51%±1.61% in Group #4004. The amount of accumulated hard-tissue debris was significantly less in Group #4004 than in the other groups. However, there were no significant differences between Groups #3004 and #3504. Conclusions An increased final apical size resulted in significantly lower debris accumulation. However, no root canal in any group was completely free from hard-tissue debris, and debris was mostly found in the isthmus of the mesial root canals.


2017 ◽  
Vol 11 (1) ◽  
pp. 71-78 ◽  
Author(s):  
Iussif Mamede-Neto ◽  
Alvaro Henrique Borges ◽  
Orlando Aguirre Guedes ◽  
Durvalino de Oliveira ◽  
Fábio Luis Miranda Pedro ◽  
...  

Introduction: The aim of this study was to evaluate, using cone-beam computed tomography (CBCT), transportation and centralization of different nickel-titanium (NiTi) rotary instruments. Methods: One hundred and twenty eight mandibular premolars were selected and instrumented using the following brands of NiTi files: WaveOne, WaveOne Gold, Reciproc, ProTaper Next, ProTaper Gold, Mtwo, BioRaCe and RaCe. CBCT imaging was performed before and after root canal preparation to obtain measurements of mesial and distal dentin walls and calculations of root canal transportation and centralization. A normal distribution of data was confirmed by the Kolmogorov-Smirnov and Levene tests, and results were assessed using the Kruskal-Wallis test. Statistical significance was set at 5%. Results: ProTaper Gold produced the lowest canal transportation values, and RaCe, the highest. ProTaper Gold files also showed the highest values for centering ability, whereas BioRaCe showed the lowest. No significant differences were found across the different instruments in terms of canal transportation and centering ability (P > 0.05). Conclusion: Based on the methodology employed, all instruments used for root canal preparation of mandibular premolars performed similarly with regard to canal transportation and centering ability.


Sign in / Sign up

Export Citation Format

Share Document