scholarly journals Determination of Glycerin from a Marketed Personal Care Product Using Gas Chromatography

2015 ◽  
Vol 2015 ◽  
pp. 1-5
Author(s):  
Amit Kumar De ◽  
Partha Pratim Chowdhury ◽  
Shyama Prasad Chattopadhyay

The current study presents a packed column gas chromatographic technique for the estimation of glycerin using a flame ionization detector from a marketed hair tonic in presence of resorcinol, ethanol, biotin, keratin hydrolysate, undecylenic acid alkylolamide (hyalkyl HBU), D-biotin, nicotinic acid, and polyvinylpyrrolidone. The validation studies show the proposed method to be specific, sensitive, precise, and accurate. The method is found to be linear in the concentration range 1.25 mg/mL to 10.02 mg/mL with r2 value 0.99. The limit of detection and the limit of quantitation were 0.01 mg/mL and 0.05 mg/mL, respectively. The method does not involve any complex sample preparation procedure and is therefore suitable for regular analysis of glycerin from marketed hair tonic.

1994 ◽  
Vol 77 (3) ◽  
pp. 583-586 ◽  
Author(s):  
Walter K Gavlick ◽  
Paula K Davis

Abstract A gas chromatographic (GC) method with flame ionization detection was developed to separate and quantitate p-chloroaniline (PCA) from other components in a chlorhexidine digluconate (CHG)-containing alcohol foam surgical scrub product. A simple sample preparation method was developed in which 1-butanol was used to dissolve the foam and precipitate the CHG, which otherwise would interfere with the GC analysis. The method was validated with respect to linear dynamic range, precision, accuracy, selectivity, limit of detection, and limit of quantitation.


Author(s):  
LAKSHMI NARASIMHA RAO KATAKAM ◽  
THIRUPATHI DONGALA

Objective: The study spotlights on a new gas chromatographic (GC) method with flame ionization detection technique that has been developed and validated for the selective determination of 1,4-dioxane content in sodium laureth sulfate (SLS), raw material. Methods: The method was developed using a Thermo Scientific TR-1 (30 m×0.25 mm×1.0 μm) column with a carrier gas used as helium. The diluent used as purified water and the flow pressure of the carrier gas is 9.0 psi with a split ratio of 1:5. The optimized method was validated as per the ICH Q2 guidelines. Results: Regression analysis confers a correlation coefficient for the stated compounds that are found to be greater than 0.999. The limit of quantitation and limit of detection are established at a sensitive determination level of 9 ppm and 3 ppm, respectively. Conclusion: The validated and rugged GC method developed for the determination of 1,4-dioxane using a specific GC method in the SLS raw material. The recovery results prove the sound judgment in the determination of accuracy toward its evaluation. Hence, the validated analytical method was specific, selective, economical, and accurate for the determination of 1,4-dioxane by gas chromatographic method with flame ionization detection technique.


2009 ◽  
Vol 92 (3) ◽  
pp. 773-778 ◽  
Author(s):  
Juan Chen ◽  
Xue-Mei Ma ◽  
Yan-Ping Shi

Abstract A high-performance liquid chromatographic technique coupled with photodiode array detection was proposed for the simultaneous determination of 7 flavonoids, i.e., quercetin, kaempferol, 7-hydroxyflavanone, 7-methoxyflavanone, 2,4-dihydroxychalcone, 2,4-dihydroxydihydrochalcone, and 7,2-dihydroxy-3, 4-dimethoxyisoflavane, in extracts of the plant Ixeridium gracile. Optimum separation was obtained by using a reversed-phase C18 method. Because of the different UV characteristics of these components, 5 detection wavelengths were used for the quantitative analysis. All of the flavonoids showed good linearity (r > 0.9999). The limit of detection and limit of quantitation values for the analytes ranged from 0.06 to 0.46 g/mL and from 0.18 to 1.48 g/mL, respectively. The method was validated by evaluating repeatability, precision, stability, and accuracy. Five different extraction and purification procedures were investigated for preparation of the sample solution. The optimized method was applied to the determination of flavonoids in I. gracile and was found to be efficient.


1991 ◽  
Vol 74 (2) ◽  
pp. 400-403
Author(s):  
Walter Fiddler ◽  
Robert C Doerr ◽  
Robert A Gates

Abstract A method Is described for analysis of minced fish-meat and surlmi-meat frankfurters for dimethylamine (DMA), trimethyiamine (TMA), and trimethyiamine oxide (TMAO) using a headspace-gas chromatographic technique. After simple acid extraction and addition of NaOH, the headspace was directly Injected Into a gas chromatograph by a gas-tight syringe. DMA and TMA were separated on a Chromosorb 103 column and detected by a flame Ionization detector. TMAO was measured as TMA after Zn reduction. Repeatability of the method for DMA, TMA, and TMAO was 6.6,1.0, and 18.8 ppm, respectively. The method was applicable to Alaska pollock-meat and Atlantic menhaden-meat frankfurters, unwashed, and washed mince and surlml.


2013 ◽  
Vol 634-638 ◽  
pp. 1586-1590
Author(s):  
Su Fang Wang ◽  
Shou Jie Zhang ◽  
Chun Hong Dong ◽  
Guo Qing Wang ◽  
Jun Feng Guo ◽  
...  

A method for simultaneous determination of residuals of four herbicides and pesticides, simazine, carboxin, diflubenzuron and rotenone, in Chinese green tea was developed. In the proposed method, the tea powder was placed in a centrifuge tube with a plug, extracted in saturated aqueous sodium chloride solution and acetonitrile, agitated using vortex oscillator, and then centrifuged 5 min at 4000 rpm. The supernatant solution was purified by primary secondary amine (PSA) sorbent, C18 power, and graphitized carbon black powder, respectively. Then the purified extracts were dissolved with acetonitrile:0.1% formic acid aqueous solution (40:60, V/V) and agitated, filtered using a syringe with 0.22 μm nylon filter prior to UPLC-MS/MS analysis. The UPLC analysis was performed on an ACQUITY UPLC® HSS T3 column (2.1 mm×100 mm, 1.8 µm), using acetonitrile-0.1% formic acid as mobile phase with the flow rate as 0.3 mL•min-1. Injection volume was 10 µL. Positive ionization mode was applied, and the ions were monitored in the multiple reaction monitoring (MRM) mode with curtain gas 0.069 MPa, collision gas 0.052 MPa, ESI ion spray voltage 5000 V, temperature 550 °C, nebulizer gas 0.24 MPa, and turbo gas 0.28 MPa. The limit of detection (LOD) and limit of quantitation (LOQ) of the proposed method are 1 μg•kg-1and 5 μg•kg-1, respectively. The average recoveries of the four pesticides at 10, 20, and 50 µg•kg-1spiking levels range from 77.4% to 95.3%. TheSupersSuperscript textcript textrelative standard deviation (RSD) (n=6) range form 11.83% to 4.52%.


Author(s):  
Sandip A Telavane ◽  
Seema Kothari ◽  
Manohar V. Lokhande

Validation is important technique for detection, progress and estimation of drugs for pharmaceutical analysis. Aim of this article was to check the progress and validation of the method employed for the Residual Solvents in Bisoprolol Fumarate by Gas Chromatographic technique. The objective of this protocol is to validate a GC method of analysis for detection and Quantification of Residual Solvents Methanol, Acetone and Methylene dichloride in Bisoprolol Fumarate. In the pharmaceutical industry, validation policy is more important for documented of validation, types of validation and validation policy. The method was developed accurately and validation parameters are explained. Chromatographic condition was GC- 2014, gas chromatograph equipped with FID detector, column: 30 m x 0.32 mm ID x 1.8 µm DB - 624 capillary column or equivalent and column temperature was 45°C (hold 7 minutes) to 250°C @ 40°C/minutes, hold at 250°C for 3 minutes. The parameters such as Accuracy, Specificity, Precision, Linearity and Range, Limit of detection (LOD), Limit of quantitation (LOQ), ruggedness, robustness and system suitability testing with residual solvent such as Methanol, Acetone and methylene dichloride. All validation parameters are used in the routine and stability analysis.


2014 ◽  
Vol 68 (11) ◽  
Author(s):  
Pavel Mikuška ◽  
Lukáš Bružeňák ◽  
Zbyněk Večeřa

AbstractA method for the rapid and sensitive determination of peroxyacetyl nitrate (PAN) in air based on a chemiluminescence reaction with an alkaline solution of luminol in the chemiluminescence aerosol detector is described. The PAN is chromatographically separated from nitrogen dioxide and ozone in a packed column filled with 5 % OV-1 on Chromosorb 30/60 and the eluted PAN is detected via the direct reaction with the luminol solution consisting of 0.002 mol L−1 luminol, 1 vol. % Brij-35 and 0.1 mol L−1 KOH. The limit of detection is 14.9 ng m−3 (3 ppt) of PAN. Alternatively, the PAN after separation is thermally converted to NO2 which is detected by the chemiluminescence reaction with a solution consisting of 0.002 mol L−1 luminol, 0.5 mol L−1 KOH, 0.2 mol L−1 Na2SO3, 0.1 mol L−1 KI, 0.05 mol L−1 EDTA and 0.5 vol. % triton X-100. The alternative approach affords the simultaneous determination of PAN and NO2. The limit of detection is 50 ppt of PAN and 50 ppt of NO2. The time resolution is 3 min. The method was applied to the measurement of ambient peroxyacetyl nitrate in air.


Author(s):  
Birva A. Athavia ◽  
Zarna R. Dedania ◽  
Ronak R. Dedania ◽  
S. M. Vijayendra Swamy ◽  
Chetana B. Prajapati

Objective: The aim and objective of this study was to develop and validate Stability Indicating HPLC method for determination of Vilazodone Hydrochloride.Methods: The method was carried out on a Phenomenex, C18 (250x4.6 mm, 5 µm) Column using a mixture of Acetonitrile: Water (50:50v/v), pH adjusted to 3.3 with Glacial Acetic Acid for separation. The flow rate was adjusted at 1 ml/min and Detection was carried out at 240 nm.Results: The retention time of vilazodone hydrochloride was found to be 2.3 min. The calibration curve was found to be linear in the range 25-75µg/ml with a correlation coefficient (R2=0.996). The limit of detection and limit of quantitation were found to be 4.78µg/ml and 14.48µg/ml respectively. The % recovery of vilazodone hydrochloride was found to be in the range of 98.21±0.08 % to 99.07±0.64%. The proposed method was successfully applied for the estimation of vilazodone hydrochloride in marketed tablet formulation.Vilazodone Hydrochloride was subjected to forced degradation under Acidic, Alkaline, Oxidation, Dry Heat and Photolytic degradation conditions. Vilazodone hydrochloride showed 3.12% degradation under acidic condition, 4.78% under alkaline condition, 7.8% under oxidation condition, 3.53% under dry heat condition and 4.9% under photolytic condition.Acid degradation impurity was identified and characterised by LC-MS/MS was found to be 1-(4-Penten-1-yl) piperazine having molecular weight 154.253 (m/z 155.08) and Molecular Formula C9H18N2.Conclusion: A simple, precise, rapid and accurate Stability Indicating HPLC method has been developed and validated for the determination of Vilazodone Hydrochloride in presence of its degradation products as per the ICH Guidelines. 


2017 ◽  
Vol 9 (2) ◽  
pp. 34
Author(s):  
N. Balaji ◽  
Sayeeda Sultana

Objective: An efficient, high performance liquid chromatographic method has been developed and validated for the quantification of related substances in pioglitazone hydrochloride drug substance.Methods: This method includes the determination of three related substances in pioglitazone hydrochloride. The mobile phase A is 0.1% w/v triethylamine in water with pH 2.5 adjusted by dilute phosphoric acid. The mobile phase B is premixed and degassed mixtures of acetonitrile and methanol. The flow rate was 1 ml/min. The elution used was gradient mode. The HPLC column used for the analysis was symmetry C18 with a length of 250 mm, the internal diameter of 4.6 mm and particle size of 5.0 microns.Results: The developed method was found to be linear with the range of 0.006-250% with a coefficient of correlation 0.99. The precision study revealed that the percentage relative standard deviation was within the acceptable limit. The limit of detection and limit of quantitation of the impurities was less than 0.002%and 0.006% with respect to pioglitazone hydrochloride test concentration of 2000 µg/ml respectively. This method has been validated as per ICH guidelines Q2 (R1).Conclusion: A reliable, economical HPLC method was magnificently established for quantitative analysis of related substances of pioglitazone hydrochloride drug substance.


Author(s):  
Abolfazl Darroudi ◽  
Saeid Nazari ◽  
Seyed Ali Marashi ◽  
Mahdi Karimi-Nazarabad

Abstract An accurate, rapid, simple, and novel technique was developed to determine simvastatin (SMV). In this research, a screen-printed electrode (SPE) was deposited with graphene oxide (GO) and sodium dodecyl sulfate (SDS), respectively. For the first time, the handmade modified SPE measured the SMV by differential pulse voltammetry (DPV) with high sensitivity and selectivity. The results of cyclic voltammetry indicated the oxidation irreversible process of SMV. Various parameters (pH, concentration, scan rate, support electrolyte) were performed to optimize the conditions for the determination of SMV. Under the optimum experiment condition of 0.1 M KNO3 as support electrolyte and pH 7.0, the linear range was achieved for SMV concentration from 1.8 to 36.6 µM with a limit of detection (LOD), and a limit of quantitation (LOQ) of 0.06 and 1.8 µM, respectively. The proposed method was successfully utilized to determine SMV in tablets and urine samples with a satisfactory recovery in the range of 96.2 to 103.3%.


Sign in / Sign up

Export Citation Format

Share Document