scholarly journals Development of a Hybrid Magnetic Resonance and Ultrasound Imaging System

2014 ◽  
Vol 2014 ◽  
pp. 1-16 ◽  
Author(s):  
Victoria Sherwood ◽  
John Civale ◽  
Ian Rivens ◽  
David J. Collins ◽  
Martin O. Leach ◽  
...  

A system which allows magnetic resonance (MR) and ultrasound (US) image data to be acquired simultaneously has been developed. B-mode and Doppler US were performed inside the bore of a clinical 1.5 T MRI scanner using a clinical 1–4 MHz US transducer with an 8-metre cable. Susceptibility artefacts and RF noise were introduced into MR images by the US imaging system. RF noise was minimised by using aluminium foil to shield the transducer. A study of MR and B-mode US image signal-to-noise ratio (SNR) as a function of transducer-phantom separation was performed using a gel phantom. This revealed that a 4 cm separation between the phantom surface and the transducer was sufficient to minimise the effect of the susceptibility artefact in MR images. MR-US imaging was demonstratedin vivowith the aid of a 2 mm VeroWhite 3D-printed spherical target placed over the thigh muscle of a rat. The target allowed single-point registration of MR and US images in the axial plane to be performed. The system was subsequently demonstrated as a tool for the targeting and visualisation of high intensity focused ultrasound exposure in the rat thigh muscle.

2017 ◽  
Vol 2017 ◽  
pp. 1-7 ◽  
Author(s):  
A. Vargas-Olivares ◽  
O. Navarro-Hinojosa ◽  
M. Maqueo-Vicencio ◽  
L. Curiel ◽  
M. Alencastre-Miranda ◽  
...  

High-intensity focused ultrasound (HIFU) is a minimally invasive therapy modality in which ultrasound beams are concentrated at a focal region, producing a rise of temperature and selective ablation within the focal volume and leaving surrounding tissues intact. HIFU has been proposed for the safe ablation of both malignant and benign tissues and as an agent for drug delivery. Magnetic resonance imaging (MRI) has been proposed as guidance and monitoring method for the therapy. The identification of regions of interest is a crucial procedure in HIFU therapy planning. This procedure is performed in the MR images. The purpose of the present research work is to implement a time-efficient and functional segmentation scheme, based on the watershed segmentation algorithm, for the MR images used for the HIFU therapy planning. The achievement of a segmentation process with functional results is feasible, but preliminary image processing steps are required in order to define the markers for the segmentation algorithm. Moreover, the segmentation scheme is applied in parallel to an MR image data set through the use of a thread pool, achieving a near real-time execution and making a contribution to solve the time-consuming problem of the HIFU therapy planning.


Author(s):  
Azadeh Moini ◽  
Amin Nikoozadeh ◽  
Jung Woo Choe ◽  
Butrus T. Khuri-Yakub ◽  
Chienliu Chang ◽  
...  

Ultrasound is increasingly in demand as a medical imaging tool and can be particularly beneficial in the field of intracardiac echocardiography (ICE). However, many challenges remain in the development of a 3D ultrasound imaging system. We have designed and fabricated a quad-ring capacitive micromachined ultrasound transducer (CMUT) for real-time, volumetric medical imaging. Each CMUT array is composed of four concentric, independent ring arrays, each operating at a different frequency, with 128 elements per ring. In this project, one ring will be used for imaging. A large (5mm diameter) lumen is available for delivering other devices, including high intensity focused ultrasound transducers for therapeutic applications or optical fibers for photoacoustic imaging. We address several challenges in developing a 3D imaging system. Through wafer vias are incorporated in the fabrication process for producing 2D CMUT arrays. Device integration with electronics is achieved through solder bumping the arrays, designing a flexible PCB, and flip chip bonding CMUT and ASICs to the flexible substrate. Finally, we describe a method for integrating the flex assembly into a catheter shaft. The package, once assembled, will be used for in-vivo open chest experiments.