scholarly journals The Nested Site Selection Model for Water Treatment Plants Based on the Optimization of Water Supply Radius

2014 ◽  
Vol 2014 ◽  
pp. 1-9
Author(s):  
Yan Li ◽  
Lianying Zhang

This paper analyzes the site selection problems of water treatment plants by utilizing the set covering model. Fully consider the influence of the pipe network arrangement on the site selection when confirming the covering radius, analyze the best water supply radius of water treatment plants combining investment benefits and pipe network optimization theory, and take the best water supply radius as the covering radius. Make the pipe network optimization nest into the site selection problem meanwhile confirming the covering radius, which fully reflect the viewpoints of the integrated logistics arrangement system. Considering the multiple solutions of the set covering model, this paper introduces the model of which the cost’s present value is minimum to make the quadratic optimization and get the best site selection results of water treatment plant. At last, this paper verifies the model by combining with the cases of water supply project construction of a county; the results prove that the model is feasible and effective. This paper expects to provide some reference for the planning design of regionally centralized water supply projects concerning villages and small towns and the site selection and construction of water treatment plant.

2021 ◽  
Vol 3 (3) ◽  
Author(s):  
Anne Louise de Melo Dores ◽  
Felipe Corrêa Veloso dos Santos

AbstractTo elaborate efficient and economical water supply systems is one of the main objectives in the sanitation companies water system projects. In order to address the challenges faced in reaching this objective, this study aims to identify, first, the relation between the percentage of non-conformed samples in treated water and the inefficiency of the filtering units installed in the water treatment plant, and second, if, by drawing the consumption variation curve it is the most efficient way to predict the storage tanks volume—comparing necessary capacity, determined by the consumption curve, and installed capacity, predict by the outdated Brazilian normative. In order to reach answers for these two questions, this study measured the operating efficiency of the treatment plant as well as have set a quantitative comparison between the two dimensioning criteria for storage tanks volume present in the literature. As a result, the analysis provided the authors to detect a focus of contamination in the single-layered filtering units, limited by the filtering capacity of 2–6 m3/(m2 day), whilst operating at 333.13 m3/(m2 day). As well as to detect by the drawing of the consumption variation curve an oversize of 68% and 60% in the dimensioning of the studied storage tanks. With the results provided by this analysis approach, it was possible to efficiently detect and correct critical impairments in the treatment phase and to conclude that a long-term analysis should be drawn in order to affirm if the consumption variation curve is the best design methodology for the reservoirs.


2016 ◽  
Vol 16 (4) ◽  
pp. 922-930 ◽  
Author(s):  
L. Richard ◽  
E. Mayr ◽  
M. Zunabovic ◽  
R. Allabashi ◽  
R. Perfler

The implementation and evaluation of biological nitrification as a possible treatment option for the small-scale drinking water supply of a rural Upper Austrian community was investigated. The drinking water supply of this community (average system input volume: 20 m3/d) is based on the use of deep anaerobic groundwater with a high ammonium content of geogenic origin (up to 5 mg/l) which must be treated to prevent the formation of nitrites in the drinking water supply system. This paper describes the implementation and operation of biological nitrification despite several constraints including space availability, location and financial and manpower resources. A pilot drinking water treatment plant, including biological nitrification implemented in sand filters, was designed and constructed for a maximum treatment capacity of 1.2 m3/h. Online monitoring of selected physicochemical parameters has provided continuous treatment performance data. Treatment performance of the plant was evaluated under standard operation as well as in the case of selected malfunction events.


2013 ◽  
Vol 3 (4) ◽  
pp. 549-556 ◽  
Author(s):  
Kaveh Sookhak Lari ◽  
Morteza Kargar

High-rate lamella settlers in clarifiers and triple media filters have been implemented in Isfahan water treatment plant (known as ‘Baba-Sheikh-Ali’) in Iran to upgrade existing clarification/filtration processes during the recent years. The applied technologies are mainly used to reduce finished water turbidity as the primary regional criterion on water quality. However, application of both technologies faced some operational limitations since they began to work. These problems are due to the existing layout of the process units and available materials. The current study focuses on performance of restricted application of the two technologies with respect to turbidity removal. Online measured turbidity data from a two-year field observation (since March 2010) are used. In particular, results show a more promising and long-term effect on turbidity removal due to tripling filter media rather than application of the lamella settlers in clarifiers. The reasons for these observations are discussed.


2019 ◽  
Vol 100 ◽  
pp. 00019 ◽  
Author(s):  
Renata Gmurkowska

During water treatment a large amount of sludge is created – in the form of sewage and sediments. The largest amounts of sludge are produced during coagulation, ozonation and backwashing rapid filters. The quality and quantity of treated water, the type and dose of used coagulants are factors affecting the quantity, composition and properties of the sludge. Sludge produced during processing of drinking water is important problem and their quantity has been increasing. The study focuses on characteristics of water treatment sludge from four water treatment plants in Cracow. It includes theoretical and experimental part. The first part is based on analysis of literature and information obtained from MPWiK [3]. The second experimental part, concerns the analysis of dry matter, organic dry matter, capillary suction time and visual parameters: the color and consistency of the sludge. Result shows that every sludge contains organic matter. The highest concentrations of organic compounds and the largest diversity has been observed in the sludge collected in the Water Treatment Plant Raba, reaching even up to 70% of organic compounds in the dry mass of sludge.


2019 ◽  
Vol 24 (1) ◽  
pp. 135-163
Author(s):  
Jader Martínez Girón ◽  
Jenny Vanessa Marín-Rivera ◽  
Mauricio Quintero-Angel

Population growth and urbanization pose a greater pressure for the treatment of drinking water. Additionally, different treatment units, such as decanters and filters, accumulate high concentrations of iron (Fe) and manganese (Mn), which in many cases can be discharged into the environment without any treatment when maintenance is performed. Therefore, this paper evaluates the effectiveness of vertical subsurface wetlands for Fe and Mn removal from wastewater in drinking water treatment plants, taking a pilot scale wetland with an ascending gravel bed with two types of plants: C. esculenta and P. australis in El Hormiguero (Cali, Colombia), as an example. The pilot system had three upstream vertical wetlands, two of them planted and the third one without a plant used as a control. The wetlands were arranged in parallel and each formed by three gravel beds of different diameter. The results showed no significant difference for the percentage of removal in the three wetlands for turbidity (98 %), Fe (90 %), dissolved Fe (97 %) and Mn (98 %). The dissolved oxygen presented a significant difference between the planted wetlands and the control. C. esculenta had the highest concentration of Fe in the root with (103.5 ± 20.8) µg/g ; while P. australis had the highest average of Fe concentrations in leaves and stem with (45.7 ± 24) µg/g and (41.4 ± 9.1) µg/g, respectively. It is concluded that subsurface wetlands can be an interesting alternative for wastewater treatment in the maintenance of drinking water treatment plants. However, more research is needed for the use of vegetation or some technologies for the removal or reduction of the pollutant load in wetlands, since each drinking water treatment plant will require a treatment system for wastewater, which in turn requires a wastewater treatment system as well.


2019 ◽  
Vol 8 (3) ◽  
pp. 93-101
Author(s):  
Paulami De

This article addresses methods to adjust operating requirements in water treatment plants (WTPs) in order to increase the efficiency of water treatment plants based on the nature of the water inflows into the systems. In the past, various studies have suggested that the quality of water inflow into the WTP has an impact on the efficiency and economic viability of operating treatment plants. Among all other quality parameters, the concentration of dissolved oxygen (DO) is one of the basic indicators about the overall quality of the water. Identification of a temporal pattern can help the engineers to adapt the WTP operations and can save the unnecessary wasting of plant resources. That is why the present article has proposed a new model that can predict the temporal patterns of various chemical parameters with the help of an analytic neuronal network. The model was applied to the case of a WTP that responds to a peri-urban catchment, leading to regular variations in the DO of water inflow. According to the performance metrics utilized the model was able to predict the temporal pattern at a lag of 1 hour.


2019 ◽  
Vol 19 (8) ◽  
pp. 2330-2337
Author(s):  
Susumu Hasegawa ◽  
Yasuhiro Tanaka ◽  
Naokazu Wake ◽  
Ryosuke Takagi ◽  
Hideto Matsuyama

Abstract Recently, membrane filtration systems have become increasingly common in drinking water treatment plants. In this industry, preventing membrane fouling is of utmost importance. Many studies on the relationship between raw water components and membrane fouling have been performed in laboratory conditions. However, very few studies have analyzed the components of foulants on the fouled membrane as operated in actual drinking water treatment plants. By analyzing these components in plant-conditions, membrane fouling will be more effectively prevented. In this study, we analyzed the components of foulants extracted with 0.1 N NaOH from a fouled membrane operated in a drinking water treatment plant in Japan. Our analysis revealed that the main foulants were humic substances. In order to dissolve the accumulated humic substances, additional chemical cleaning was attempted with 500 ppm sodium hypochlorite. As a result, it was found that humic substances were dissolved and filtration resistance significantly decreased. Additionally, the removal of inorganic foulants was also greater after chemical cleaning with 500 ppm sodium hypochlorite, as inorganic foulants trapped within humic substances were released to the membrane surface as hydroxides by the additional sodium hypochlorite cleaning and were dissolved by the periodic citric acid cleaning.


Sign in / Sign up

Export Citation Format

Share Document