scholarly journals Tribological behavior of Ti-6Al-4V and Ti-6Al-7Nb Alloys for Total Hip Prosthesis

2014 ◽  
Vol 2014 ◽  
pp. 1-13 ◽  
Author(s):  
Mamoun Fellah ◽  
Mohamed Labaïz ◽  
Omar Assala ◽  
Leila Dekhil ◽  
Ahlem Taleb ◽  
...  

The aim of the study is to evaluate the friction and wear behavior of high-strength alloys Ti-6Al-7Nb used in femoral stem and compare it with a Ti-6Al-4V alloy cylindrical bar corresponding to ISO 5832-3 part 3/01-07-199 standard. The tribological behavior was investigated by wear tests, using ball-on-disc and pin-on-disc tribometers. These tests consisted of measuring the weight loss and the friction coefficient of samples. The oscillating friction and wear tests have been carried out in ambient with oscillating tribotester in accordance with standards ISO 7148, ASTM G99-95a, and ASTM G133-95 under different conditions of normal loads (3, 6, and 10 N) and sliding speeds (1, 15, and 25 mm·s−1). As counter pairs, a 100Cr6 steel ball with 10 mm in diameter was used. Results show that the two alloys had similar friction and wear performance, although their grain structures and compositions are different. Occurrence of large frictional occurred, is probably caused by formation and periodic, localized fracture of a transfer layer. Higher friction with larger fluctuation and higher wear rate was observed at the higher siding speed. The Ti-6Al-4V wear mechanism transforms from ploughing and peeling off wear at low sliding speed to plastic deformation and adhesive wear.

2021 ◽  
Vol 63 (5) ◽  
pp. 470-473
Author(s):  
Subramaniam Shankar ◽  
Rajavel Nithyaprakash ◽  
Balasubramaniam Rajasulochana Santhosh

Abstract Reduction in wear of artificial bio-implants results in the release of a lesser amount of wear particles into the blood stream. This paper focuses on analyzing the tribological behavior of ceramic and polyethylene bio-materials experimentally. Four different biomaterials namely Zirconia, Silicon Nitride, UHMWPE (ultra high molecular weight polyethylene) and PEEK (polyether ether ketone) are investigated for friction and wear coefficients using a pin on disc (PoD) tribometer. Alumina (Al2O3) is chosen as the disc material. Polyethylene based UHMWPE and PEEK are used as a pin material with the hemispherical end, while, Zirconia and Silicon Nitride ceramic materials are used in the form of spherical ball. 0.9 % NaCl (saline solution) is used as a lubricant medium. Zirconia showed a better reduction in friction and wear coefficient characteristics under lubrication conditions when compared with polyethylene and other ceramic materials. The estimated friction and wear coefficients would be helpful for surgeons and academicians to choose better wear-resistant bio-compatible materials for effectively design hip prosthesis. The present study compared the tribological behaviors of ceramic materials Si3N4 and ZrO2 and polyethylene materials PEEK and UHMWPE with a ceramic counterpart Al2O3 disc. In the lubrication case, ZrO2 showed a better reduction in friction and wear characteristics while in the dry case UHMWPE showed lesser wear characteristics.


2015 ◽  
Vol 67 (1) ◽  
pp. 22-29 ◽  
Author(s):  
Akin Akinci

Purpose – The purpose of this paper is to investigate the friction and wear performance of pure polycarbonate (PC) and 5-30 per cent wollastonite-filled (by weight) PC were comparatively evaluated under dry sliding conditions. Wear tests were carried out at room temperature under the loads of 5-20 N and at the sliding speeds of 0.5-1.5 m/s. Design/methodology/approach – The microstructures of the wollastonite, pure PC and composites were examined by optical microscopy, scanning electron microscopy, energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD) analysis. The friction and wear tests were realized using a pin-on-disk arrangement against the hardened AISI 4140 steel. Findings – The result of this study indicated that the coefficients of friction wear rate of the materials were significantly influenced by an increase in wollastonite content. The friction coefficient of the PC was getting decreased from 0.457 to 0.198 with an increase in wollastonite content, depending on applied loads and sliding speeds. On the other hand, the results showed that the wear rates of pure PC and wollastonite-filled PCs decreased with an increase in loads. The wear rate of the PC decreased from 1.2 × 10−6 to 8.7 × 10−6 mm3/m with an increase in wollastonite content, depending on applied loads. Originality/value – There are many reports which deal with the friction and wear performance of the polymers and polymer composites. However, the effect of wollastonite effect on tribological performance of PC has up to now not been extensively researched.


2000 ◽  
Vol 643 ◽  
Author(s):  
Alan Duckham ◽  
Dan Shechtman ◽  
Benjamin Grushko

AbstractThe influence of grain orientation on the friction and wear behavior of single-phase quasicrystalline alloys is investigated. Pin-on-disc wear tests and friction coefficient measurements have been performed on bulk samples of icosahedral phase AlPdMn and decagonal phase AlNiCo alloys. Wear behavior has been evaluated by optical microscopy, scanning electron microscopy (SEM) and electron back-scattered diffraction (EBSD). Coefficient of friction values of the decagonal AlNiCo alloy are found to be widely scattered (between 0.03 and 0.55) compared to the far more consistent values of the icosahedral alloys. This is explained by considering the significant variation in wear behavior that is observed between different – sometimes adjacent – oriented grains in the decagonal specimens.


Author(s):  
Santanu Duari ◽  
Arkadeb Mukhopadhyay ◽  
Tapan Kumar Barman ◽  
Prasanta Sahoo

This paper presents an experimental study on tribological behavior of electroless Ni-B coating under lubricated condition based on Taguchi’s method. Mild steel specimens are used as the substrate material for the deposition of Ni-B coating and the thickness of the deposits is found to be around 35 μm. Based on Taguchi’s L27 orthogonal array of experiments, the wear tests are done on a pin-on-disc type tribotester This experiment is carried out by utilizing the combination of process parameters of the tribotester like normal load, sliding speed and duration of sliding. The analysis of the experimental data is carried out with the help of MINITAB® software package. It is seen that the normal load is the most significant factor followed by sliding time at 99% confidence level. The surface morphology, composition and compound analysis of the coatings are done by means of scanning electron microscope, energy dispersed X-ray micro-analyzer and X-ray diffraction analyzer respectively. Finally, a confirmation test is carried out to validate the analysis.


Author(s):  
S. De Palo ◽  
S. Usmani ◽  
S. Sampath ◽  
D.J. Sordelet ◽  
M. Besser

Abstract Gas atomized Al63Cu25Fe12 powders of varying size fractions were plasma sprayed to study the relationships between coating microstructure and tribological behavior. After spraying, annealing was performed on one of the coatings. Abrasion and sliding wear tests were performed on the coatings. The results indicate a correlation between the abrasion resistance and hardness of the coatings. Furthermore, sliding wear tests reveal lower coefficients of friction for the as-sprayed coatings compared to the annealed coatings.


2021 ◽  
Vol 9 ◽  
Author(s):  
Biao Ma ◽  
Bin Luo ◽  
Zhuozheng Wang ◽  
Chuiyi Meng ◽  
Xiujie He

Friction and wear performance is one of the key mechanical properties of accident tolerant fuel cladding coatings. In this study, reciprocating sliding wear tests had performed on two types of CrAl and CrAlN coatings with two different Al content ratios and Zr-4. The coefficient of friction, wear depth, and abrasion loss were measured and compared. The results indicated that the CrAl-based coatings improve the wear behavior significantly and nitrogen has an obvious improvement on the wear resistance of the coating. The friction and wear performance was also studied in a water environment. The results show that the presence of water degrade the wear performance of Zr-4 and CrAl coatings but ameliorates the friction and wear performance of CrAlN coatings. The feasibility of depositing ATF coating on conventional Zr-4 substrates to mitigate the influence of grid-to-rod fretting was demonstrated.


Author(s):  
S. Ingole ◽  
R. Ribeiro ◽  
O. Juan ◽  
H. Liang ◽  
M. Usta ◽  
...  

Boronized tungsten is one of the potential biomaterials due to its high corrosion resistance, and high strength. Present investigation encompasses the wear behavior of this material in dry condition as well as in simulated body fluid (SBF). The pin-on-disc reciprocating tribometer was utilized to conduct the wear tests. The worn surfaces were analyzed using an atomic force microscope (AFM). Results showed that not only the SBF reduces the friction, but also shortens the initial break-in period. This presentation discusses the wear mechanisms of boronized tungsten affected by SBF.


2016 ◽  
Vol 51 (19) ◽  
pp. 2805-2812 ◽  
Author(s):  
G Miranda ◽  
M Buciumeanu ◽  
MM Costa ◽  
F Bartolomeu ◽  
FS Silva ◽  
...  

This study is concerned with the influence of four metallic reinforcements on aluminum-silicon (AlSi) composites, with respect to wear behavior. AlSi-Ti; AlSi-Ti6Al4V; AlSi-1.4301 stainless steel and AlSi-Ni particulate reinforced composites were produced by a hot-pressing route. Microstructural characterization showed a uniform distribution of the reinforcing particles in the AlSi matrix. Reciprocating pin-on-plate wear tests were performed for AlSi and AlSi-based composites against gray cast iron plates. In order to compare the effect of different metallic particulates on the AlSi-based composites/gray cast iron tribopair wear performance, besides the pin, the counterface was also analyzed. The particle/matrix interface is analyzed in order to understand its influence on the tribopair behavior and on the controlling wear mechanisms. It was shown that the better compromise between both sliding surfaces performance was attained by AlSi-Ni/gray cast iron tribopair.


2017 ◽  
Vol 24 (4) ◽  
pp. 485-494 ◽  
Author(s):  
Iskender Ozsoy ◽  
Adullah Mimaroglu ◽  
Huseyin Unal

AbstractIn this study, the influence of micro- and nanofiller contents on the tribological performance of epoxy composites was studied. The fillers are micro-Al2O3, micro-TiO2, and micro-fly ash and nano-Al2O3, nano-TiO2, and nanoclay fillers. The microfillers were added to the epoxy by 10%, 20%, and 30% by weight. The nanofillers were added to the epoxy by 2.5%, 5%, and 10%. Friction and wear tests were conducted using the pin-on-disc arrangement. Tribo elements consisted of polymer pin and DIN 1.2344 steel counterface disc. A load value of 15 N, a sliding speed of 0.4 m/s, a sliding distance of 2000 m, and dry atmospheric conditions were applied to test conditions. The results show that the friction coefficients and the specific wear rates of the nanofilled composites increase as the filler content increases. For microfiller-filled epoxy composites, these values decrease as filler content increases. The tribological performance of epoxy composites is enhanced by the addition of microfillers, and the higher enhancement is reached with the addition of 30% fly ash filler. Finally, the pin and disc worn surface images show the presence of adhesive and some abrasive wear mechanisms.


Author(s):  
Takashi Nogi

Some tribological properties of an ionic liquid were investigated by using a pin-on-disc friction and wear tester. Due to running-in, the coefficient of friction of the ionic liquid decreased with time to a very low value of 0.02 which suggests that the lubrication regime was hydrodynamic at the end of the tests. Anti-wear performance of the ionic liquid was substantially comparable to a paraffin-based oil.


Sign in / Sign up

Export Citation Format

Share Document