scholarly journals Fouling Removal of UF Membrane with Coated TiO2Nanoparticles under UV Irradiation for Effluent Recovery during TFT-LCD Manufacturing

2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
S. H. You ◽  
C. T. Wu

An ultrafiltration (UF) membrane process was employed to treat the secondary effluent discharged from a manufacturing of thin film transistor-liquid crystal display (TFT-LCD) in this study. A bench-scale system was performed to evaluate the fouling removal of a UF membrane with coated titanium dioxide (TiO2) nanoparticles under UV irradiation. The operating pressure and feed temperature were controlled at 300 KN/m2and 25°C, respectively. It was found that the optimum operating conditions were attained with TiO2concentrations of 10 wt% for both 5 KD and 10 KD MWCO. Continuous UV irradiation of 5 KD MWCO improved the permeate flux rate from 45.0% to 59.5% after 4 hours of operation. SEM-EDS analysis also showed that the photocatalytic effect had reduced the average thickness of cake fouling on the membrane from 6.40 μm to 2.70 μm for 5 KD MWCO and from 6.70 μm to 3.1 μm for 10 KD MWCO. In addition, the membrane contact angle was reduced from 54° to 44°. The photocatalytic properties of TiO2apparently increased the hydrophilicity of the membrane surface, thereby reducing membrane fouling.

Membranes ◽  
2020 ◽  
Vol 10 (7) ◽  
pp. 142
Author(s):  
Qian Liu ◽  
Lixin Xie ◽  
Hanxiao Du ◽  
Shichang Xu ◽  
Yawei Du

In the production of acrylic acid, the concentration of acrylic acid solution from the adsorption tower was low, which would lead to significant energy consumption in the distillation process to purify acrylic acid, along with the production of a large amount of wastewater. Reverse osmosis (RO) was proposed to concentrate the acrylic acid aqueous solution taken from a specific tray in the absorption tower. The effects of operating conditions on the permeate flux and acid retention were studied with two commercial RO membranes (SWC5 and SWC6). When the operating pressure was 4 MPa and the temperature was 25 °C, the permeate fluxes of two membranes were about 20 L·m−2·h−1. The acrylic acid and acetic acid retentions were about 80% and 78%, respectively. After being immersed in the acid solutions for several months, the characteristics of the two membranes were tested to evaluate their acid resistance. After six months of exposure to the acid solution containing 2.5% acrylic acid and 2.5% acetic acid, the retentions of acrylic acid and acetic acid were decreased by 5.7% and 4.1% for SWC5 and 4.9% and 2.2% for SWC6, respectively. The changes of membrane surface morphology and chemical composition showed the hydrolysis of some amide bonds.


Author(s):  
Nina Zhou ◽  
A. G. Agwu Nnanna

Low pressure driven ultrafiltraion (UF) processes has been applied in various industries due to its economical and easy operated benefits. Hollow fiber membrane is one of the most used membrane configuration in industry, membrane fouling is the major challenge for widely usage. Most of the investigation of UF was carried out by experiments to determine the effect of different operating conditions on permeate flux. However, experiments provide limited insight information on the membrane performance. In addition, the prediction of permeate flux under different operating conditions is necessary for experimental design and optimization. The purpose of the present study is to develop a numerical model to simulate the UF process and investigate the UF mechanism. A numerical model was developed using commercial CFD package (FLUENT). The effects of various operating conditions on permeate flux were determined by experiments and simulations, the comparison of the experimental and CFD results shows good agreements. Controlling membrane fouling will maintain a high productivity. The simulations were carried out to investigate the efficiency of removing accumulated particles on membrane surface by installing spacer filaments in membrane channels. The results suggested that the zigzag type spacer has d/h = 0.5 and l/h = 5 is more economical and efficient in reducing fouling.


2013 ◽  
Vol 2013 ◽  
pp. 1-6
Author(s):  
Shu-Hai You ◽  
Ming-Hua Guo

In this study, a combination of TiO2-film photocatalysis reactor and ultrafiltration was used treat the secondary effluent from the manufacturing of thin film transistor-liquid crystal display (TFT-LCD). TiO2particles, as a photocatalyst, were immobilized on silica glass to form TiO2-film by the sol-gel and dip coating methods. TiO2-film photocatalysis was done within three parameters, including number of coating times of TiO2-film, wavelengths of UV light source, and operating time. During ultrafiltration, the operating pressure and feed water temperature were controlled at 300 KN/m2and 25°C, respectively. It was found that TiO2-film photocatalysis followed by ultrafiltration increased the removal of total organic carbon (TOC) to 47.13% and 49.94% for 5 KDa and 10 KDa membranes, respectively. It was also found that the process increased the permeate flux rate (ca 23%) for 10 KDa membrane after 6 hours of operation, since some larger organic matter had been broken into small organic matter and some small organic matter had been mineralized into CO2following TiO2-film photocatalysis. Therefore, combining TiO2-film photocatalysis reactor and ultrafiltration can improve organic wastewater quality and increase the permeate flux of ultrafiltration membrane, which may enhance the recycling and reuse of wastewater.


2019 ◽  
Vol 46 (4) ◽  
pp. 299-307 ◽  
Author(s):  
Anirban Banik ◽  
Suman Dutta ◽  
Tarun Kanti Bandyopadhyay ◽  
Sushant Kumar Biswal

The paper investigates increasing permeate flux (%) of the disc membrane which can improve the quality of rubber industrial effluent of Tripura. Response surface methodology was used to optimize the independent influencing parameters to improve the permeate flux. The effect of different influencing parameters like operating pressure, membrane pore size, and inlet feed velocity on membrane permeate flux were studied to determine the optimum operating conditions within the predefined boundary. The experiments were pre-planned and designed according to central composite rotatable design, and second-order polynomial regression model was developed for regression and analysis of variance study. Results show the membrane has maximum permeate flux (%) when the operating pressure is 14.50 Pa, pore size is 0.20 μm, and inlet feed velocity is 2.10 m/s. The Pareto analysis in the study established that the inlet velocity was the most influential parameter in the model equation.


2016 ◽  
Vol 17 (1) ◽  
pp. 300-310 ◽  
Author(s):  
Xudong Wang ◽  
Danxi Huang ◽  
Lei Wang ◽  
Xiaorong Meng ◽  
Yongtao Lv ◽  
...  

Membrane processes often experience a decline in the permeate flux or an increase in the operating pressure from membrane fouling. A mathematical model that describes the fouling of inside-out hollow fiber ultrafiltration (UF) membranes was derived from hydrodynamic equations coupled with the theory of depth filtration. The correlation predictions obtained in this study are simpler, as the effect of membrane characteristics, water recovery, and membrane washing processes on UF membrane fouling were expressed using a single parameter: the membrane blocking coefficient. Membrane filtration tests were conducted using diluted paper industry wastewater in a constant-pressure and constant-current operational mode. The effects of different operating conditions, such as water recovery and cleaning methods, and membrane characteristics, on the membrane blocking coefficient were evaluated. The predictive capability of the proposed model was excellent, according to a comparison of the experimental results and model simulations.


2006 ◽  
Vol 6 (1) ◽  
pp. 69-78 ◽  
Author(s):  
T. Harif ◽  
M. Hai ◽  
A. Adin

Electroflocculation (EF) is a coagulation/flocculation process in which active coagulant species are generated in situ by electrolytic oxidation of an appropriate anode material. The effect of colloidal suspension pretreatment by EF on membrane fouling was measured by flux decline at constant pressure. An EF cell was operated in batch mode and comprised two flat sheet electrodes, an aluminium anode and stainless steel cathode, which were immersed in the treated suspension, and connected to an external DC power supply. The cell was run at constant current between 0.06–0.2A. The results show that pre-EF enhances the permeate flux at pH 5 and 6.5, but only marginal improvement is observed at pH 8. At all pH values cake formation on the membrane surface was observed. The differences in membrane behavior can be explained by conventional coagulation theory and transitions between aluminium mononuclear species which affect particle characteristics and consequently cake properties. At pH 6.5, where sweep floc mechanism dominates due to increased precipitation of aluminium hydroxide, increased flux rates were observed. It is evident that EF can serve as an efficient pretreatment to ultrafiltration of colloid particles.


Author(s):  
Sina Jahangiri Mamouri ◽  
Volodymyr V. Tarabara ◽  
André Bénard

Deoiling of produced or impaired waters associated with oil and gas production represents a significant challenge for many companies. Centrifugation, air flotation, and hydrocyclone separation are the current methods of oil removal from produced water [1], however the efficiency of these methods decreases dramatically for droplets smaller than approximately 15–20 μm. More effective separation of oil-water mixtures into water and oil phases has the potential to both decrease the environmental footprint of the oil and gas industry and improve human well-being in regions such as the Gulf of Mexico. New membrane separation processes and design of systems with advanced flow management offer tremendous potential for improving oil-water separation efficacy. However, fouling is a major challenge in membrane separation [2]. In this study, the behavior of oil droplets and their interaction with crossflow filtration (CFF) membranes (including membrane fouling) is studied using computational fluid dynamics (CFD) simulations. A model for film formation on a membrane surface is proposed for the first time to simulate film formation on membrane surfaces. The bulk multiphase flow is modeled using an Eulerian-Eulerian multiphase flow model. A wall film is developed from mass and momentum balances [3] and implemented to model droplet deposition and membrane surface blockage. The model is used to predict film formation and subsequent membrane fouling, and allow to estimate the actual permeate flux. The results are validated using available experimental data.


2021 ◽  
Author(s):  
Amira Abdelrasoul

The low-pressure membrane applications are considered to be the most effective and sustainable methods of addressing environmental problems in treating water and wastewater that meets or exceed stringent environmental standards. Nevertheless, membrane fouling is one of the primary operational concerns that is currently hindering a more widespread application of ultrafiltration (UF) with a variety of contaminants. Membrane fouling leads to higher operating costs, higher energy demand, reduced membrane life time, and increased cleaning frequency. As a consequence, an efficient and well-planned UF process is becoming a necessity for consistent and long-term monetary returns. Examining the source and mechanisms of foulant attachment to the membrane’s surface is critical when it comes to the research of membrane fouling and its potential practical implementation. A mathematical model was developed in this study in order to predict the amount of fouling based on an analysis of particle attachments. This model was developed using both homogeneous and heterogeneous membranes, with a uniform and non-uniform pore sizes for the UF of simulated latex effluent with a wide range of particle size distribution. The objective of this mathematical model was to effectively identify and address the common shortcomings of previous fouling models, and to account for the existing chemical attachments in membrane fouling. The mathematical model resulting from this study was capable of accurately predicting the mass of fouling retained by the membrane and the increase in transmembrane pressure (TMP). In addition, predictive models of fouling attachments were derived and now form an extensive set of mathematical models necessary for the prediction of membrane fouling at a given operating condition, as well as, the various membrane surface charges. Polycarbonate and Polysulfone flat membranes, with pore sizes of 0.05 μm and a molecular weight cut off of 60,000 respectively, were used in the experimental designs under a constant feed flow rate and a cross-flow mode in UF of the simulated latex paint effluent. The TMP estimated from the model agreed with the experimentally measured values at different operating conditions, mostly within 5.0 - 8.0 % error, and up to 13.0% error for the uniform, and non-uniform pore size membranes, respectively. Furthermore, different types of membranes with a variety of molecular weight cut-off (MWCO) values were tested so as to evaluate the accuracy of the models for a generalized application. In addition , a power consumption model, incorporating fouling attachment as well as chemical and physical factors in membrane fouling, was developed in order to ensure accurate prediction and scale-up. Innovative remediation techniques were likewise developed and applied in order to minimize membrane fouling, enhance the membrane performance, and save energy. Fouling remediation methodologies included the pre-treating of the latex effluent, so as to limit its fouling propensity by using different types of surfactants as cationic and anionic, in addition to the pH change. The antifouling properties of the membranes were improved through the implementation of the membrane pH treatment and anionic surfactant treatment. Increasing the ionic strength of latex effluent or enhancing the membrane surface hydrophilicity facilitated a significant increase in the cumulative permeate flux, a substantial decrease in the total mass of fouling, and a noticeable decrease in the specific power consumption.


2021 ◽  
Author(s):  
Amira Abdelrasoul

The low-pressure membrane applications are considered to be the most effective and sustainable methods of addressing environmental problems in treating water and wastewater that meets or exceed stringent environmental standards. Nevertheless, membrane fouling is one of the primary operational concerns that is currently hindering a more widespread application of ultrafiltration (UF) with a variety of contaminants. Membrane fouling leads to higher operating costs, higher energy demand, reduced membrane life time, and increased cleaning frequency. As a consequence, an efficient and well-planned UF process is becoming a necessity for consistent and long-term monetary returns. Examining the source and mechanisms of foulant attachment to the membrane’s surface is critical when it comes to the research of membrane fouling and its potential practical implementation. A mathematical model was developed in this study in order to predict the amount of fouling based on an analysis of particle attachments. This model was developed using both homogeneous and heterogeneous membranes, with a uniform and non-uniform pore sizes for the UF of simulated latex effluent with a wide range of particle size distribution. The objective of this mathematical model was to effectively identify and address the common shortcomings of previous fouling models, and to account for the existing chemical attachments in membrane fouling. The mathematical model resulting from this study was capable of accurately predicting the mass of fouling retained by the membrane and the increase in transmembrane pressure (TMP). In addition, predictive models of fouling attachments were derived and now form an extensive set of mathematical models necessary for the prediction of membrane fouling at a given operating condition, as well as, the various membrane surface charges. Polycarbonate and Polysulfone flat membranes, with pore sizes of 0.05 μm and a molecular weight cut off of 60,000 respectively, were used in the experimental designs under a constant feed flow rate and a cross-flow mode in UF of the simulated latex paint effluent. The TMP estimated from the model agreed with the experimentally measured values at different operating conditions, mostly within 5.0 - 8.0 % error, and up to 13.0% error for the uniform, and non-uniform pore size membranes, respectively. Furthermore, different types of membranes with a variety of molecular weight cut-off (MWCO) values were tested so as to evaluate the accuracy of the models for a generalized application. In addition , a power consumption model, incorporating fouling attachment as well as chemical and physical factors in membrane fouling, was developed in order to ensure accurate prediction and scale-up. Innovative remediation techniques were likewise developed and applied in order to minimize membrane fouling, enhance the membrane performance, and save energy. Fouling remediation methodologies included the pre-treating of the latex effluent, so as to limit its fouling propensity by using different types of surfactants as cationic and anionic, in addition to the pH change. The antifouling properties of the membranes were improved through the implementation of the membrane pH treatment and anionic surfactant treatment. Increasing the ionic strength of latex effluent or enhancing the membrane surface hydrophilicity facilitated a significant increase in the cumulative permeate flux, a substantial decrease in the total mass of fouling, and a noticeable decrease in the specific power consumption.


2011 ◽  
Vol 64 (12) ◽  
pp. 2404-2409 ◽  
Author(s):  
A. Akbari ◽  
M. Homayoonfal ◽  
V. Jabbari

A composite nanofiltration membrane was developed by a poly(acrylic acid) in situ ultraviolet (UV) graft polymerization process using an ultrafiltration polysulfone membrane as a porous support, by a phase inversion method. SEM images showed that the PSf membranes had numerous finger-like pores. Atomic force microscopy (AFM) showed that the roughness of the surface was reduced by an increase in UV irradiation times. The rejections of sodium chloride and sodium sulfate were moderate and declined with the increase of concentration. We observed that by increasing UV irradiation time and nanofiltration pressure applied, retention of dyes was enhanced and in the most irradiated membrane (M-4 membrane) at 4 bars, color removal with a high rejection of about 99.80% was achieved. It was found that the separation efficiency of dyes in the mixture of salt and dyes decreased with the salt concentration due to a decrease in the Donnan effect. It was also found that by varying the pH, the membrane surface and the dyes' charges are changed, which meant that the membrane surface and dyes had different interactions at various pHs.


Sign in / Sign up