scholarly journals A Kit to Facilitate and Standardize the Processing of Sputum for Measurements of Airway Inflammation

2013 ◽  
Vol 20 (4) ◽  
pp. 248-252 ◽  
Author(s):  
Simone Chaboillez ◽  
Angira Dasgupta ◽  
Philippe Prince ◽  
Louis-Philippe Boulet ◽  
Catherine Lemière

BACKGROUND: The use of inflammometry has been shown to be effective for managing asthma. However, sputum processing can be time consuming. Furthermore, methods of sputum processing can vary among facilities. To help with standardization and to simplify the procedure for laboratory staff, a novel, commercially available processing device (Accufilter, Cellometrics Inc, Canada) has been developed.OBJECTIVE: To assess the validity of the Accufilter device and kit for recovery of treated specimens, and for quantitative sputum inflammatory cell counts by comparing intrasample measurements with those using the same procedure without the Accufilter device and kit.METHODS: The present study was a wet laboratory comparison of induced sputum cell counts obtained from sputum processed with versus without the device and kit. Comparisons of each sputum specimen were performed by the same technologist in random order.RESULTS: A total of 39 samples were processed using both the standard method and the Accufilter device. The intraclass correlation coefficients were high for the weight of the filtrate, and for eosinophil and neutrophil differential counts.CONCLUSION: A good degree of agreement of results was apparent when the two methods were compared. The differences noted between both methods were minimal and did not modify clinical interpretation. The use of the Accufilter device and kit can be used in place of the standard method for sputum quantitative analysis, especially in centres with large sample loads.

2012 ◽  
Vol 23 (07) ◽  
pp. 534-541 ◽  
Author(s):  
Susan Gordon-Hickey ◽  
Elizabeth Adams ◽  
Robert Moore ◽  
Ashley Gaal ◽  
Katie Berry ◽  
...  

Background: The acceptable noise level (ANL) serves to accurately predict the listener's likelihood of success with amplification. It has been proposed as a pre–hearing aid fitting protocol for hearing aid selection and counseling purposes. The ANL is a subjective measure of the listener's ability to accept background noise. Measurement of ANL relies on the tester and listener to follow the instructions set forth. To date, no research has explored the reliability of ANL as measured across clinicians or testers. Purpose: To examine the intertester reliability of ANL. Research Design: A descriptive quasi-experimental reliability study was completed. ANL was measured for one group of listeners by three testers. Study Sample: Three participants served as testers. Each tester was familiar with basic audiometry. Twenty-five young adults with normal hearing served as listeners. Data Collection/Analysis: Each tester was stationed in a laboratory with the needed equipment. Listeners were instructed to report to these laboratories in a random order provided by the experimenters. The testers assessed most comfortable listening level (MCL) and background noise level (BNL) for all 25 listeners. Results: Intraclass correlation coefficients were significant and revealed that MCL, BNL, and ANLs are reliable across testers. Additionally, one-way ANOVAs for MCL, BNL, and ANL were not significant. These findings indicate that MCL, BNL, and ANL do not differ significantly when measured by different testers. Conclusions: If the ANL instruction set is accurately followed, ANL can be reliably measured across testers, laboratories, and clinics. Intertester reliability of ANL allows for comparison across ANLs measured by different individuals. Findings of the present study indicate that tester reliability can be ruled out as a factor contributing to the disparity of mean ANLs reported in the literature.


2020 ◽  
Vol 29 (3) ◽  
pp. 1650-1654
Author(s):  
Cara Donohue ◽  
James L. Coyle

Purpose In dysphagia research involving kinematic analyses on individual swallow parameters, randomization is used to ensure judges are not influenced by judgments made for other parameters within the same swallow or by judgments made for other swallows from the same participant. Yet, the necessity of randomizing swallows to avoid bias during kinematic analyses is largely assumed and untested. This study investigated whether randomization of the order of swallows presented to judges impacts analyses of temporal kinematic events from videofluoroscopic swallow studies. Method One hundred twenty-seven swallows were analyzed from 18 healthy adults who underwent standardized videofluoroscopic swallow studies. Swallows were first analyzed by two trained raters sequentially, analyzing all kinematic events within each swallow, and then a second time in random order, measuring one kinematic event at a time. Intrarater reliability measurements were calculated between random and sequential swallow judgments for all kinematic events using intraclass correlation coefficient and percent exact agreement within a three-frame tolerance. Results Intraclass correlation coefficients (1.00) and percent exact agreement (89%) were excellent for all kinematic events between analyses methods, indicating there were no significant differences in measurements performed in random or sequential order. Conclusions This study provides preliminary evidence that randomization may be unnecessary during temporal swallow kinematic data analyses for research, which may lead to more efficient analyses and dissemination of findings, and alignment of findings with clinical interpretations. Replication of this design with swallows from people with dysphagia would strengthen the generalizability of the results.


2020 ◽  
Vol 6 (1) ◽  
pp. 00289-2019
Author(s):  
Rishi J. Khusial ◽  
Persijn J. Honkoop ◽  
Victor van der Meer ◽  
Jiska B. Snoeck-Stroband ◽  
Jacob K. Sont

ObjectiveSeveral newly developed eHealth applications use online questionnaires to monitor asthma control. The Asthma Control Questionnaire (ACQ) and Asthma Quality of Life Questionnaire (AQLQ) are two such commonly used questionnaires. These questionnaires are validated for use on paper. This study aims to validate them by assessing the agreement between online and paper versions of the ACQ and AQLQ.MethodsPatients (aged 18 years and older) from the Self-Management in Asthma Supported by Hospitals, ICT, Nurses and General Practitioners (SMASHING)-trial and Davos@home study were included in this study. Patients completed both the paper and online Dutch versions of the ACQ and AQLQ in a random order within a 2-week interval. Agreement between the different versions was assessed with paired t-tests, intraclass correlation coefficients and Bland–Altman plots.ResultsIn total 44 patients were eligible for analysis. The mean difference between the paper and online versions of the ACQ was 0.04 (p=0.40) and for the AQLQ it was 0.08 (p=0.06). The intraclass correlation coefficient scores were 0.94 for the ACQ and 0.95 for the AQLQ.ConclusionThe online versions of the ACQ and AQLQ show high levels of agreement with the paper versions and can therefore be safely used in eHealth applications to respectively monitor asthma control and quality of life.


Author(s):  
Julia Schmid ◽  
Vanessa Gut ◽  
Nina Schorno ◽  
Takuya Yanagida ◽  
Achim Conzelmann

Affective well-being is positively linked to regular exercise. Therefore, it is important to identify the factors that influence intra-individual variability of affective well-being. This study investigated (1) whether affective responses vary within an individual and (2) how affective responses are associated with a motive–incentive fit and a skill–task fit. A total of 107 adults (66% females, Mage = 41.79 years old, 58% doing no exercise) took part in three exercise sessions in a random order. Each session lasted 30 min with a break of 10 min between. The sessions were similarly structured but covered diverse activity incentives (e.g., figure vs. social contact vs. aesthetic movements). Intraclass correlation coefficients showed a very high within-person variation of affective valence and enjoyment across the exercise sessions. The results of multi-level regression analyses revealed that associations between perceived competence, considered to be an indicator of the skill–task fit, and affective well-being were moderate to high, whereas those between motive–incentive fit and affective well-being were low to moderate.


2020 ◽  
Vol 124 (11) ◽  
pp. 1229-1240 ◽  
Author(s):  
Suey S. Y. Yeung ◽  
Marijke C. Trappenburg ◽  
Carel G. M. Meskers ◽  
Andrea B. Maier ◽  
Esmee M. Reijnierse

AbstractObjective measurement of RMR may be important for optimal nutritional care but is hindered by the price and practicality of the metabolic monitoring device. This study compared two metabolic monitoring devices for measuring RMR and VO2 and compared the measured RMR with the predicted RMR calculated from equations. RMR was measured using QUARK RMR (reference device) and Fitmate GS (COSMED) in a random order for 30 min, each on fasted participants. In total, sixty-eight adults participated (median age 22 years, interquartile range 21–32). Pearson correlation showed that RMR (r 0·86) and VO2 (r 0·86) were highly correlated between the two devices (P < 0·05). Intraclass correlation coefficients (ICC) showed good relative agreements regarding RMR (ICC = 0·84) and VO2 (ICC = 0·84) (P < 0·05). RMR measured by QUARK RMR was significantly higher (649 (sd 753) kJ/d) than Fitmate GS. Equations significantly overpredicted RMR. Accurate RMR (i.e. within ±10 % of the RMR measured by QUARK RMR) was found among 38 % of the participants for Fitmate GS and among 46–68 % depending on the equations. Bland–Altman analysis showed a low absolute agreement with QUARK RMR at an individual level for both Fitmate GS (limits of agreement (LOA): −828 to +2125 kJ/d) and equations (LOA ranged from −1979 to +1879 kJ/d). In conclusion, both Fitmate GS and predictive equations had low absolute agreements with QUARK RMR at an individual level. Therefore, these limitations should be considered when determining RMR using Fitmate GS or equations.


1991 ◽  
Vol 34 (5) ◽  
pp. 989-999 ◽  
Author(s):  
Stephanie Shaw ◽  
Truman E. Coggins

This study examines whether observers reliably categorize selected speech production behaviors in hearing-impaired children. A group of experienced speech-language pathologists was trained to score the elicited imitations of 5 profoundly and 5 severely hearing-impaired subjects using the Phonetic Level Evaluation (Ling, 1976). Interrater reliability was calculated using intraclass correlation coefficients. Overall, the magnitude of the coefficients was found to be considerably below what would be accepted in published behavioral research. Failure to obtain acceptably high levels of reliability suggests that the Phonetic Level Evaluation may not yet be an accurate and objective speech assessment measure for hearing-impaired children.


Author(s):  
Marcos A Soriano ◽  
G Gregory Haff ◽  
Paul Comfort ◽  
Francisco J Amaro-Gahete ◽  
Antonio Torres-González ◽  
...  

The aims of this study were to (I) determine the differences and relationship between the overhead press and split jerk performance in athletes involved in weightlifting training, and (II) explore the magnitude of these differences in one-repetition maximum (1RM) performances between sexes. Sixty-one men (age: 30.4 ± 6.7 years; height: 1.8 ± 0.5 m; body mass 82.5 ± 8.5 kg; weightlifting training experience: 3.7 ± 3.5 yrs) and 21 women (age: 29.5 ± 5.2 yrs; height: 1.7 ± 0.5 m; body mass: 62.6 ± 5.7 kg; weightlifting training experience: 3.0 ± 1.5 yrs) participated. The 1RM performance of the overhead press and split jerk were assessed for all participants, with the overhead press assessed on two occasions to determine between-session reliability. The intraclass correlation coefficients (ICC) and 95% confidence intervals showed a high reliability for the overhead press ICC = 0.98 (0.97 – 0.99). A very strong correlation and significant differences were found between the overhead press and split jerk 1RM performances for all participants (r = 0.90 [0.93 – 0.85], 60.2 ± 18.3 kg, 95.7 ± 29.3 kg, p ≤ 0.001). Men demonstrated stronger correlations between the overhead press and split jerk 1RM performances (r = 0.83 [0.73-0.90], p ≤ 0.001) compared with women (r = 0.56 [0.17-0.80], p = 0.008). These results provide evidence that 1RM performance of the overhead press and split jerk performance are highly related, highlighting the importance of upper-limb strength in the split jerk maximum performance.


Dysphagia ◽  
2021 ◽  
Author(s):  
Sofie Albinsson ◽  
Lisa Tuomi ◽  
Christine Wennerås ◽  
Helen Larsson

AbstractThe lack of a Swedish patient-reported outcome instrument for eosinophilic esophagitis (EoE) has limited the assessment of the disease. The aims of the study were to translate and validate the Eosinophilic Esophagitis Activity Index (EEsAI) to Swedish and to assess the symptom severity of patients with EoE compared to a nondysphagia control group. The EEsAI was translated and adapted to a Swedish cultural context (S-EEsAI) based on international guidelines. The S-EEsAI was validated using adult Swedish patients with EoE (n = 97) and an age- and sex-matched nondysphagia control group (n = 97). All participants completed the S-EEsAI, the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire-Oesophageal Module 18 (EORTC QLQ-OES18), and supplementary questions regarding feasibility and demographics. Reliability and validity of the S-EEsAI were evaluated by Cronbach’s alpha and Spearman correlation coefficients between the domains of the S-EEsAI and the EORTC QLQ-OES18. A test–retest analysis of 29 patients was evaluated through intraclass correlation coefficients. The S-EEsAI had sufficient reliability with Cronbach’s alpha values of 0.83 and 0.85 for the “visual dysphagia question” and the “avoidance, modification and slow eating score” domains, respectively. The test–retest reliability was sufficient, with good to excellent intraclass correlation coefficients (0.60–0.89). The S-EEsAI domains showed moderate correlation to 6/10 EORTC QLQ-OES18 domains, indicating adequate validity. The patient S-EEsAI results differed significantly from those of the nondysphagia controls (p < 0.001). The S-EEsAI appears to be a valid and reliable instrument for monitoring adult patients with EoE in Sweden.


Author(s):  
Jens Sörensen ◽  
Jonny Nordström ◽  
Tomasz Baron ◽  
Stellan Mörner ◽  
Sven-Olof Granstam ◽  
...  

Abstract Aim To develop a method for diagnosing left ventricular (LV) hypertrophy from cardiac perfusion 15O-water positron emission tomography (PET). Methods We retrospectively pooled data from 139 subjects in four research cohorts. LV remodeling patterns ranged from normal to severe eccentric and concentric hypertrophy. 15O-water PET scans (n = 197) were performed with three different PET devices. A low-end scanner (66 scans) was used for method development, and remaining scans with newer devices for a blinded evaluation. Dynamic data were converted into parametric images of perfusable tissue fraction for semi-automatic delineation of the LV wall and calculation of LV mass (LVM) and septal wall thickness (WT). LVM and WT from PET were compared to cardiac magnetic resonance (CMR, n = 47) and WT to 2D-echocardiography (2DE, n = 36). PET accuracy was tested using linear regression, Bland–Altman plots, and ROC curves. Observer reproducibility were evaluated using intraclass correlation coefficients. Results High correlations were found in the blinded analyses (r ≥ 0.87, P < 0.0001 for all). AUC for detecting increased LVM and WT (> 12 mm and > 15 mm) was ≥ 0.95 (P < 0.0001 for all). Reproducibility was excellent (ICC ≥ 0.93, P < 0.0001). Conclusion 15O-water PET might detect LV hypertrophy with high accuracy and precision.


Author(s):  
Igor Junio de Oliveira Custódio ◽  
Gibson Moreira Praça ◽  
Leandro Vinhas de Paula ◽  
Sarah da Glória Teles Bredt ◽  
Fabio Yuzo Nakamura ◽  
...  

This study aimed to analyze the intersession reliability of global positioning system (GPS-based) distances and accelerometer-based (acceleration) variables in small-sided soccer games (SSG) with and without the offside rule, as well as compare variables between the tasks. Twenty-four high-level U-17 soccer athletes played 3 versus 3 (plus goalkeepers) SSG in two formats (with and without the offside rule). SSG were performed on eight consecutive weeks (4 weeks for each group), twice a week. The physical demands were recorded using a GPS with an embedded triaxial accelerometer. GPS-based variables (total distance, average speed, and distances covered at different speeds) and accelerometer-based variables (Player Load™, root mean square of the acceleration recorded in each movement axis, and the root mean square of resultant acceleration) were calculated. Results showed that the inclusion of the offside rule reduced the total distance covered (large effect) and the distances covered at moderate speed zones (7–12.9 km/h – moderate effect; 13–17.9 km/h – large effect). In both SSG formats, GPS-based variables presented good to excellent reliability (intraclass correlation coefficients – ICC > 0.62) and accelerometer-based variables presented excellent reliability (ICC values > 0.89). Based on the results of this study, the offside rule decreases the physical demand of 3 versus 3 SSG and the physical demands required in these SSG present high intersession reliability.


Sign in / Sign up

Export Citation Format

Share Document