The Evaluation of State-of-the-Art Front-End Structures by the Differential Hall Effect Continuous Anodic Oxidation Technique

2019 ◽  
Vol 19 (1) ◽  
pp. 135-146 ◽  
Author(s):  
Simon A. Prussin ◽  
Jason Reyes
2008 ◽  
Author(s):  
S. Prussin ◽  
Shu Qin ◽  
Jason Reyes ◽  
Allen Mcteer ◽  
Edmund G. Seebauer ◽  
...  

Author(s):  
Manjunath K. E. ◽  
Srinivasa Raghavan K. M. ◽  
K. Sreenivasa Rao ◽  
Dinesh Babu Jayagopi ◽  
V. Ramasubramanian

In this study, we evaluate and compare two different approaches for multilingual phone recognition in code-switched and non-code-switched scenarios. First approach is a front-end Language Identification (LID)-switched to a monolingual phone recognizer (LID-Mono), trained individually on each of the languages present in multilingual dataset. In the second approach, a common multilingual phone-set derived from the International Phonetic Alphabet (IPA) transcription of the multilingual dataset is used to develop a Multilingual Phone Recognition System (Multi-PRS). The bilingual code-switching experiments are conducted using Kannada and Urdu languages. In the first approach, LID is performed using the state-of-the-art i-vectors. Both monolingual and multilingual phone recognition systems are trained using Deep Neural Networks. The performance of LID-Mono and Multi-PRS approaches are compared and analysed in detail. It is found that the performance of Multi-PRS approach is superior compared to more conventional LID-Mono approach in both code-switched and non-code-switched scenarios. For code-switched speech, the effect of length of segments (that are used to perform LID) on the performance of LID-Mono system is studied by varying the window size from 500 ms to 5.0 s, and full utterance. The LID-Mono approach heavily depends on the accuracy of the LID system and the LID errors cannot be recovered. But, the Multi-PRS system by virtue of not having to do a front-end LID switching and designed based on the common multilingual phone-set derived from several languages, is not constrained by the accuracy of the LID system, and hence performs effectively on code-switched and non-code-switched speech, offering low Phone Error Rates than the LID-Mono system.


2021 ◽  
Vol 6 (1) ◽  
pp. 47
Author(s):  
Julian Schütt ◽  
Rico Illing ◽  
Oleksii Volkov ◽  
Tobias Kosub ◽  
Pablo Nicolás Granell ◽  
...  

The detection, manipulation, and tracking of magnetic nanoparticles is of major importance in the fields of biology, biotechnology, and biomedical applications as labels as well as in drug delivery, (bio-)detection, and tissue engineering. In this regard, the trend goes towards improvements of existing state-of-the-art methodologies in the spirit of timesaving, high-throughput analysis at ultra-low volumes. Here, microfluidics offers vast advantages to address these requirements, as it deals with the control and manipulation of liquids in confined microchannels. This conjunction of microfluidics and magnetism, namely micro-magnetofluidics, is a dynamic research field, which requires novel sensor solutions to boost the detection limit of tiny quantities of magnetized objects. We present a sensing strategy relying on planar Hall effect (PHE) sensors in droplet-based micro-magnetofluidics for the detection of a multiphase liquid flow, i.e., superparamagnetic aqueous droplets in an oil carrier phase. The high resolution of the sensor allows the detection of nanoliter-sized superparamagnetic droplets with a concentration of 0.58 mg cm−3, even when they are only biased in a geomagnetic field. The limit of detection can be boosted another order of magnitude, reaching 0.04 mg cm−³ (1.4 million particles in a single 100 nL droplet) when a magnetic field of 5 mT is applied to bias the droplets. With this performance, our sensing platform outperforms the state-of-the-art solutions in droplet-based micro-magnetofluidics by a factor of 100. This allows us to detect ferrofluid droplets in clinically and biologically relevant concentrations, and even in lower concentrations, without the need of externally applied magnetic fields.


Sign in / Sign up

Export Citation Format

Share Document