The Effects of Hydrostatic Pressure on the Elastic Properties of Cat Veins

1974 ◽  
Vol 52 (2) ◽  
pp. 148-152 ◽  
Author(s):  
J. Kenneth Booking ◽  
Margot R. Roach

Simultaneous measurements of pressure and volume were made on seven isolated external jugular veins and four femoral veins from cats. The measurements were made before and after the veins were held at an intraluminal pressure of 800 mm H2O. Circumferential tensions were calculated from Laplace's law (tension = pressure × radius). After being held at 800 mm H2O for periods of time up to 18 h, the resting radius of the vein increased and it became less distensible. Possible implications of these results concerning varicose veins are discussed. Since tension = pressure × radius, then as the radius increases and the pressure stays constant (as in varicose veins), the tension increases. If tension causes varicose veins then a vicious circle is set up which may result in the development of very severe varices.

1974 ◽  
Vol 52 (2) ◽  
pp. 153-157 ◽  
Author(s):  
J. Kenneth Booking ◽  
Margot R. Roach

Simultaneous measurements of pressure and volume were made on nine great saphenous veins obtained at autopsies and nine great saphenous veins that were stripped during surgery from patients with primary varicose veins. Similar measurements were also made on six great saphenous veins obtained at autopsy before and after they were held at 100 cm H2O for 4 h. Circumferential tensions were calculated from Laplace's law (tension = pressure × radius).The great saphenous veins from patients with primary varicose veins had significantly greater radii and were more distensible than the normal great saphenous veins. After being held at 100 cm H2O for 4 h, the normal great saphenous veins became less distensible and their radii at distending pressures increased.Due to the great difference in radii, the circumferential tension on a great saphenous vein from a patient with primary varicose veins is much greater than that on a normal great saphenous vein at the same distending pressure. However, the physical stresses exerted on the great saphenous veins during the stripping operations may influence our results in some unknown way.


Author(s):  
T. Gulik-Krzywicki ◽  
M.J. Costello

Freeze-etching electron microscopy is currently one of the best methods for studying molecular organization of biological materials. Its application, however, is still limited by our imprecise knowledge about the perturbations of the original organization which may occur during quenching and fracturing of the samples and during the replication of fractured surfaces. Although it is well known that the preservation of the molecular organization of biological materials is critically dependent on the rate of freezing of the samples, little information is presently available concerning the nature and the extent of freezing-rate dependent perturbations of the original organizations. In order to obtain this information, we have developed a method based on the comparison of x-ray diffraction patterns of samples before and after freezing, prior to fracturing and replication.Our experimental set-up is shown in Fig. 1. The sample to be quenched is placed on its holder which is then mounted on a small metal holder (O) fixed on a glass capillary (p), whose position is controlled by a micromanipulator.


1995 ◽  
Vol 05 (C8) ◽  
pp. C8-729-C8-734
Author(s):  
A.I. Lotkov ◽  
V.P. Lapshin ◽  
V.A. Goncharova ◽  
H.V Chernysheva ◽  
V.N. Grishkov ◽  
...  

Author(s):  
Hongying Shan ◽  
Chuang Wang ◽  
Cungang Zou ◽  
Mengyao Qin

This paper is a study of the dynamic path planning problem of the pull-type multiple Automated Guided Vehicle (multi-AGV) complex system. First, based on research status at home and abroad, the conflict types, common planning algorithms, and task scheduling methods of different AGV complex systems are compared and analyzed. After comparing the different algorithms, the Dijkstra algorithm was selected as the path planning algorithm. Secondly, a mathematical model is set up for the shortest path of the total driving path, and a general algorithm for multi-AGV collision-free path planning based on a time window is proposed. After a thorough study of the shortcomings of traditional single-car planning and conflict resolution algorithms, a time window improvement algorithm for the planning path and the solution of the path conflict covariance is established. Experiments on VC++ software showed that the improved algorithm reduces the time of path planning and improves the punctual delivery rate of tasks. Finally, the algorithm is applied to material distribution in the OSIS workshop of a C enterprise company. It can be determined that the method is feasible in the actual production and has a certain application value by the improvement of the data before and after the comparison.


Coatings ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 319
Author(s):  
Zhiguo Lu ◽  
Chuanyu Du ◽  
Qingcai Chen ◽  
Tianying Niu ◽  
Na Wang ◽  
...  

The friction and wear characteristics of spike-tooth material (65Mn steel) of Spike-Tooth Harrow in a two-stage peanut harvester were studied in this paper. The friction and wear tests of pin and disc on 65 manganese steel were carried out on the tribometer, then the wear loss and the friction coefficient were studied. The wear loss of the pin was acquired by calculating the mass of the pin before and after the experiment using an electronic balance. According to the actual working environment of peanut spring-finger, four variable parameters are set up: load, speed, soil moisture and soil type. The friction and wear characteristics of pins were studied under different loads, speeds and different soil environments. After wearing, the worn surface of the material was observed by scanning microscope and the wear mechanism was studied. The experimental results show that the wear of the pin increases with the increase of load and decreases with the increase of rotational speed in the same rotation number. Especially in the case of the sandy soil with 20% in moisture, a maximum wear loss of the pin is achieved.


Landslides ◽  
2021 ◽  
Author(s):  
Lorenzo Brezzi ◽  
Alberto Bisson ◽  
Davide Pasa ◽  
Simonetta Cola

AbstractA large number of landslides occur in North-Eastern Italy during every rainy period due to the particular hydrogeological conditions of this area. Even if there are no casualties, the economic losses are often significant, and municipalities frequently do not have sufficient financial resources to repair the damage and stabilize all the unstable slopes. In this regard, the research for more economically sustainable solutions is a crucial challenge. Floating composite anchors are an innovative and low-cost technique set up for slope stabilization: it consists in the use of passive sub-horizontal reinforcements, obtained by coupling a traditional self-drilling bar with some tendons cemented inside it. This work concerns the application of this technique according to the observational method described within the Italian and European technical codes and mainly recommended for the design of geotechnical works, especially when performed in highly uncertain site conditions. The observational method prescribes designing an intervention and, at the same time, using a monitoring system in order to correct and adapt the project during realization of the works on the basis of new data acquired while on site. The case study is the landslide of Cischele, a medium landslide which occurred in 2010 after an exceptional heavy rainy period. In 2015, some floating composite anchors were installed to slow down the movement, even if, due to a limited budget, they were not enough to ensure the complete stabilization of the slope. Thanks to a monitoring system installed in the meantime, it is now possible to have a comparison between the site conditions before and after the intervention. This allows the evaluation of benefits achieved with the reinforcements and, at the same time, the assessment of additional improvements. Two stabilization scenarios are studied through an FE model: the first includes the stabilization system built in 2015, while the second evaluates a new solution proposed to further increase the slope stability.


2019 ◽  
Vol 152 (Supplement_1) ◽  
pp. S131-S132
Author(s):  
Kathryn Hogan ◽  
Beena Umar ◽  
Mohamed Alhamar ◽  
Kathleen Callahan ◽  
Linoj Samuel

Abstract Objectives There are few papers that characterize types of errors in microbiology laboratories and scant research demonstrating the effects of interventions on microbiology lab errors. This study aims to categorize types of culture reporting errors found in microbiology labs and to document the error rates before and after interventions designed to reduce errors and improve overall laboratory quality. Methods To improve documentation of error incidence, a self-reporting system was changed to an automatic reporting system. Errors were categorized into five types Gram stain (misinterpretations), identification (incorrect analysis), set up labeling (incorrect patient labels), procedures (not followed), and miscellaneous. Error rates were tracked according to technologist, and technologists were given real-time feedback by a manager. Error rates were also monitored in the daily quality meeting and frequently detected errors were discussed at staff meetings. Technologists attended a year-end review with a manager to improve their performance. To maintain these changes, policies were developed to monitor technologist error rate and to define corrective measures. If a certain number of errors per month was reached, technologists were required to undergo retraining by a manager. If a technologist failed to correct any error according to protocol, they were also potentially subject to corrective measures. Results In 2013, we recorded 0.5 errors per 1,000 tests. By 2018, we recorded only 0.1 errors per 1,000 tests, an 80% decrease. The yearly culture volume from 2013 to 2018 increased by 32%, while the yearly error rate went from 0.05% per year to 0.01% per year, a statistically significant decrease (P = .0007). Conclusion This study supports the effectiveness of the changes implemented to decrease errors in culture reporting. By tracking errors in real time and using a standardized process that involved timely follow-up, technologists were educated on error prevention. This practice increased safety awareness in our micro lab.


LWT ◽  
2017 ◽  
Vol 78 ◽  
pp. 289-295 ◽  
Author(s):  
Rubén Pérez Pulido ◽  
Ma José Grande Burgos ◽  
Antonio Gálvez ◽  
Rosario Lucas

Sign in / Sign up

Export Citation Format

Share Document