Gamma-induced attenuation in normal single-mode and multimode, Ge-doped and P-doped optical fibers: A fiber optic dosimeter for low dose levels

2000 ◽  
Vol 78 (2) ◽  
pp. 89-97 ◽  
Author(s):  
Ping Lu ◽  
Xiaoyi Bao ◽  
Kellie Brown ◽  
Narayan Kulkarni

Ge-doped, P-doped, normal single-mode (SM) and multimode (MM) optical fibers were exposed to Cobalt-60 gamma radiation at dose rates of 0.5 and 3.0 Gy/min, typical radiotherapy dose rates. A CCD-based fiber optic spectrometer was used to measure the real-time absorption spectra of these fibers in the visible region. Experimental results have shown that P-doped fiber is the most radiation-sensitive of the fibers tested. At the wavelength of 502 nm, the radiation-induced loss in P-doped fiber shows a linear relationship with the total dose with no dose-rate dependence. This indicates that dose rates have no influence on a fiber optic dosimeter operating at this wavelength. The radiation-induced losses in normal MM fibers, Ge-doped MM fibers, and Ge-doped SM fibers are shownto be dose-rate dependent. PACS No.: 42.62nBe, 42.81-i

Actuators ◽  
2021 ◽  
Vol 10 (6) ◽  
pp. 107
Author(s):  
Nakash Nazeer ◽  
Xuerui Wang ◽  
Roger M. Groves

This paper presents a study on trailing edge deflection estimation for the SmartX camber morphing wing demonstrator. This demonstrator integrates the technologies of smart sensing, smart actuation and smart controls using a six module distributed morphing concept. The morphing sequence is brought about by two actuators present at both ends of each of the morphing modules. The deflection estimation is carried out by interrogating optical fibers that are bonded on to the wing’s inner surface. A novel application is demonstrated using this method that utilizes the least amount of sensors for load monitoring purposes. The fiber optic sensor data is used to measure the deflections of the modules in the wind tunnel using a multi-modal fiber optic sensing approach and is compared to the deflections estimated by the actuators. Each module is probed by single-mode optical fibers that contain just four grating sensors and consider both bending and torsional deformations. The fiber optic method in this work combines the principles of hybrid interferometry and FBG spectral sensing. The analysis involves an initial calibration procedure outside the wind tunnel followed by experimental testing in the wind tunnel. This method is shown to experimentally achieve an accuracy of 2.8 mm deflection with an error of 9%. The error sources, including actuator dynamics, random errors, and nonlinear mechanical backlash, are identified and discussed.


2021 ◽  
Vol 3 (1) ◽  
pp. 45-56
Author(s):  
Imam Mulyanto

The analysis of fiber optics for macro bending-based slope sensors using SMF-28 single-mode optical fibers has been successfully conducted. Fiber optics were treated to silicon rubber molding and connected with laser light and power meters to measure the intensity of laser power generated. The working principle was carried out using the macrobending phenomenon on single-mode optical fibers. The intensity of laser light in fiber optic cables decreases in the event of indentation or bending of the fiber optic cable. Power losses resulting from the macrobending process can be seen in the result of the information sensitivity of fiber optics to the change of angle given. From the results of the study, the resulting fiber optic sensitivity value is -0.1534o/dBm. The larger the angle given, the lower the laser intensity received by the power meter.


2019 ◽  
Vol 9 (2) ◽  
pp. 11-15
Author(s):  
Sisca Arisya Harry Andhina

Macrobending often occurs in optical fibers that embedded in the ground due to shifting of soil or rocks in the ground causing interference in transmission. In this study used single-mode-multimode-singlemode fiber optic cable connected manually and axially measured using a light source test equipment and optical power meter and the results will be compared. The measurement results obtained the greater  value of macrobending losses with the smaller the diameter of the winding, and the greater the number of turns. The highest value of macrobending losses in multimode cables is -1.48dB at 0.5cm diameter with 5 turns, highest value of macrobending losses on single mode cables is -12.73dB at 0.5cm diameter with 5 turns,  lowest value of macrobending losses for multimode cables is -0.44dB at 5cm diameter with 1 twist, lowest macrobending losses in singlemode cables is -1.69dB at 5cm diameter with 1 twist. While the value of macrobending losses on axially connected SMS cables shows the highest value of macrobending losses on multimode cables is -1.12dB in diameter of 0.5cm with 5 turns,  highest value of macrobending losses on singlemode cables is -1.18dB at diameter of 0.5cm with 5 turns,  lowest value for macrobending losses on multimode cables is -0.66dB at 5cm in diameter with 1 twist, the smallest value for macrobending losses on singlemode cables is -0.27dB at 5cm diameter with 1 twist . The measurement results also showed that the macrobending losses of manually connected SMS cables were greater than the macrobending losses of axially connected SMS cables.


1998 ◽  
Vol 20 (2) ◽  
pp. 103-112 ◽  
Author(s):  
H. Wen ◽  
D.G. Wiesler ◽  
A. Tveten ◽  
B. Danver ◽  
A. Dandridge

This paper presents several designs of high-sensitivity, compact fiber-optic ultrasound sensors that may be used for medical imaging applications. These sensors translate ultrasonic pulses into strains in single-mode optical fibers, which are measured with fiber-based laser interferometers at high precision. The sensors are simpler and less expensive to make than piezoelectric sensors, and are not susceptible to electromagnetic interference. It is possible to make focal sensors with these designs, and several schemes are discussed. Because of the minimum bending radius of optical fibers, the designs are suitable for single element sensors rather than for arrays.


Author(s):  
А.D. Меkhtiyev ◽  
◽  
E.G. Neshina ◽  
P.Sh. Madi ◽  
D.A. Gorokhov ◽  
...  

This article ls with the issues related to the development of a system for monitoring the deformation and displacement of the rock mass leading to the collapse of the quarry sides. Monitoring system uses point-to-point fiber-optic sensors. Fiber-optic sensors and control cables of the communication line are made based on the single mode optical fibers, which allows to measure with high accuracy the deformations and displacements of the rock mass at a distance of 30-50 km. To create fiber-optic pressure sensors, an optical fiber of the ITU-T G. 652.D standard is used. Laboratory sample is developed concerning the point fiber-optic sensor made based on the two-arm Mach-Zender interferometer using a single mode optical fiber for monitoring strain (displacements) with a change in the sensitivity and a reduced influence of temperature interference leading to zero drift. The article presents a mathematical apparatus for calculating the intensity of radiation of a light wave passing through an optical fiber with and without mechanical stress. A laboratory sample of single mode optical fibers based on the Mach-Zender interferometer showed a fairly high linearity and accuracy in the measurement and can be used to control the strain of the mass after appropriate refinement of its design. Mathematical expressions are also given for determining the intensity of the light wave when the distance between the fixing points of a single mode optical fiber changes depending on the change in the external temperature. A diagram for measuring strain using a point fiber-optic strain sensor is developed. Hardware and software package is developed, which can be used to perform a number of settings of measuring channels. The work is aimed at solving the production problems of the Kenzhem quarry of AK Altynalmas JSC.


2014 ◽  
Author(s):  
B. Singleton ◽  
J. Petrosky ◽  
M. Pochet ◽  
N. G. Usechak ◽  
S. A. Francis

2021 ◽  
Vol 1 ◽  
pp. 15-16
Author(s):  
Aleksander Wosniok ◽  
Katerina Krebber

Abstract. The international research efforts focused on the development of radiation sensors based on optic fibers have their origins in the 1970s (Evans et al., 1978). Generally, the lightweight fiber optic sensors are immune to electromagnetic field interference and high voltages making them deployable in harsh environments at hard to reach areas where conventional sensors usually will not work at all. A further advantage of such radiation sensors is the possibility of remote and real-time monitoring (Huston et al., 2001). In this work, we present our results achieved in several research activities for development of fiber optic dosimeters. The findings show that both the measurement of the radiation-induced attenuation (RIA) along the entire sensing fiber and the accompanying change in the refractive index of the fiber core can be used for distributed radiation monitoring in the kGy and MGy range, respectively. Depending on the fiber type and material the RIA shows varying response to dose rates, environmental temperatures and the wavelength of the laser source used. Thereby, an operation with visible laser light provides most favorable performance in terms of high radiation sensitivity. Operating at these wavelengths, RIA monitoring could yield high-sensitivity dose measurement with sub-gray resolution and accuracy (Stajanca and Krebber, 2017b); however, conventional optical time-domain reflectometry (OTDR) systems for RIA measurements operating in the visible range suffer from low-spatial resolution, long measurement times and poor signal-to-noise (SNR) ratio. The limitations of the OTDR performance can be overcome by the incoherent optical frequency domain reflectometry (I-OFDR) developed by the Federal Institute of Materials Research and Testing (BAM, Liehr et al., 2009) with potential for dynamic real-time measurement. Over the years, several highly radiation sensitive fibers, such as perfluorinated polymer optical fibers (PF-POF, Stajanca and Krebber, 2017a), phosphorous-doped silica optical fibers (SOF, Paul et al., 2009), aluminium-doped SOF (Faustov et al., 2013) and erbium-doped SOF (Wosniok et al., 2016) have been identified and are commercially available. As mentioned before, the radiation-induced RIA increase is associated with an increase in the refractive index leading also to material compaction in the fiber core. The latter two effects can be used for measuring radiation distribution based on Brillouin scattering in the range of high radiation doses of several MGy (Phéron et al., 2012; Wosniok et al., 2016). When using fiber optic sensors for radiation monitoring, the existing post-irradiation annealing behavior of the optical fiber sensors must also be considered.


Sign in / Sign up

Export Citation Format

Share Document