Design of shear reinforcement for thick plates using a strut-and-tie model

2010 ◽  
Vol 37 (2) ◽  
pp. 181-194 ◽  
Author(s):  
H. Marzouk ◽  
E. Rizk ◽  
R. Tiller

The strut-and-tie method is a rational approach to structural concrete design that results in a uniform and consistent design philosophy. A strut-and-tie model has been developed to model the punching-shear behaviour of thick concrete plates. This model provides a quick and simple approach to check the punching-shear behaviour. Thick concrete slabs (250–500 mm) without shear reinforcement can exhibit brittle shear failure under a central force and an unbalanced moment. Shear reinforcement has proven to be very effective in preventing such failures. The developed strut-and-tie model has also been used to evaluate the minimum shear reinforcement required to prevent brittle shear failure of two-way slabs in the vicinity of concentrated loads. The strut-and-tie model for symmetric punching consists of a “bottle-shaped” compressive zone in the upper section of the slab depth, leading to a “rectangular-stress” compressive zone in the lower section of the slab depth. Inclined shear cracking develops in the bottle-shaped zone prior to failure in the lower zone. Cracking in the bottle-shaped zone is related to the splitting tensile strength of concrete.

2017 ◽  
Vol 738 ◽  
pp. 25-35
Author(s):  
Lukáš Lyčka ◽  
Petr Štěpánek

The use of flat slabs in constructions due to its many functional and economic advantages is wide-spread. Behavior of flat slabs in shear and flexure is a fairly complex problem. Therefore, the punching shear failure belongs to one of the most critical aspects in the design of concrete buildings.The purpose of this paper is to describe a framework of the proposed method for predicting the punching shear of flat slabs with shear reinforcement. Most of the current codes in force are mainly based on empirical formulation. The proposed method is based on a strut-and-tie model and therefore could be considered as an analytical approach. For the purpose of demonstrating the effectiveness of the proposed method, the method is compared with some of the main methods currently in use, such as Eurocode EC2, ACI 318 and Model Code 2010. The comparison consists of results of more than 90 experiments on flat slabs with shear reinforcement, gathered from publications from all around the world.


2017 ◽  
Vol 259 ◽  
pp. 178-183
Author(s):  
Lukáš Lyčka ◽  
Petr Štěpánek

The purpose of this paper is to describe a framework of the proposed method for predicting the punching shear of flat slabs with shear reinforcement. The proposed method is based on a strut-and-tie model. Current methods of predicting the punching shear strength of flat slabs could be divided into these categories: models based on empirical equations, physical models, analytical methods and finite element methods. Most of the current codes in force would be best described as empirical formulations. Physical model for prediction of punching shear is described in Model Code 2010. Proposed method for flat slabs with shear reinforcement is based mainly on a strut-and-tie model and therefore could be considered as an analytical method.For the purpose of demonstrating the effectiveness of the proposed method, the method is compared with some of the main methods currently in use, such as Eurocode EC2, American code ACI 318 and Model Code 2010. The comparison consists of results of more than 98 experiments of punching shear on the flat slabs with shear reinforcement, gathered from publications from all around the world.


2014 ◽  
Vol 13 (3) ◽  
pp. 183-192
Author(s):  
Tadeusz Urban ◽  
Jakub Krakowski

The punching shear behavior of thick reinforced concrete slabs was analyzed in this paper by using strut-and-tie model (S-T). Calculating procedures were compared to our own experimental test results. The analyzed elements were subjected to symmetric loading and without shear reinforcement.


2019 ◽  
Vol 292 ◽  
pp. 146-152
Author(s):  
Amr Abdelkhalik ◽  
Tamer Elafandy ◽  
Amr Abdelrahman ◽  
Alaa Sherif

Reinforced concrete flat slab-column structures are widely used because of their practicality. However, this type of structures can be subjected to punching-shear failure within the slab-column connections. Without shear reinforcement, the slab-column connection can undergo brittle punching failure, especially when the structure is subjected to lateral loading in seismic zones. This research is a part of an extensive investigation about the punching shear behaviour of interior RC slab-column connections under seismic loading. The main objective is to discuss the effect of the gravity shear level on the punching shear behaviour[1].The current paper represents only the results of the first four tested specimens without shear reinforcement. The first specimen was tested subjected to vertical gravity load only without cyclic loading while the other three specimens were tested under different vertical loads V which was kept constant during testing in addition to a reversed displacement controlled cyclic loading which was increased up to punching shear failure. The gravity load V was chosen as 0.4, 0.6 and 0.8 V0 respectively, where V0 is the vertical load causing punching shear failure according to ACI318-14[2]. All tested specimens have the same slab dimensions of 2000x2000mm, slab thickness 200mm, flexural reinforcement ratio of 1.62% and the same column dimensions 250mm x 250mm. Finally, the experimental results are analyzed and compared to international codes such as American Code ACI318-14 and Euro Code EC2-2004[3]. In light of these results, some preliminary conclusions are presented.


Author(s):  
V. Kavinkumar ◽  
R. Elangovan

<div><p><em>This research is to study the mechanical properties of Self Compacting Concrete (SCC) as well as punching shear failure of SCC slabs. Self compacting concrete was first invited in 1988 to achieve durable concrete structures .Design of Reinforced concrete slab is often compromised by their ability to resist shear stress at punching shear surface area. The connection between slabs and supporting columns could be susceptible to high shear stress and might cause sudden and brittle failure. Punching shear failure takes the form of truncated pyramid shape. This program includes investigating the effect of SCC, slab thickness on the punching shear behaviour in terms of load-deflection response and ultimate failure load, failure characteristic of punching shear failure (shape of failure zone and size of failure zone) of simply supported slabs of 1000 x 1000 x 50 and 75mm under concentrated load at centre of slab. The slabs are made with both SCC and Conventional concrete (CC). Investigation included two way specimens with different thickness to evaluate the performance of specimen with different thickness and the effect of thickness on punching shear capacity and performance</em>.</p></div>


Author(s):  
Kyoung-Kyu Choi ◽  
Gia Toai Truong ◽  
Seon-Du Kim ◽  
In-Rak Choi

2002 ◽  
Vol 29 (4) ◽  
pp. 602-611 ◽  
Author(s):  
Ehab F El-Salakawy ◽  
Maria Anna Polak ◽  
Khaled A Soudki

The paper presents work on punching shear rehabilitation and strengthening of existing slab–column connections. Four full-scale specimens representing slab–column edge connections were built and tested to failure. Three slabs were then repaired and strengthened and tested again. In the originally tested slabs, which were chosen for repair, one slab had an opening in front of the column and contained shear reinforcement, one slab had an opening and no shear reinforcement, and one had no opening and no reinforcement. The dimensions of the slabs were 1540 × 1020 × 120 mm with square columns (250 × 250 mm). The openings in the specimens were square (150 × 150 mm) with the sides parallel to the sides of the column. The slabs were made using normal weight concrete (28-day average compressive strength of 32 MPa) and reinforced with a reinforcement ratio of 0.75%. The slabs were repaired by replacing old-damaged concrete with new concrete of the same properties. Strengthening was carried out using shear studs for the two slabs, which originally did not have shear reinforcement. The rehabilitation increased the punching shear strength (by 26–41%) and the ductility of the connections. All repaired specimens failed in flexure.Key words: concrete slabs, punching shear, rehabilitation, edge connections, openings, studs, repair.


Author(s):  
Fatma M. Eid ◽  
Tayel Magdy ◽  
Ebada Ahmed

Punching shear failure is a major problem encountered in the design of reinforced concrete flat slabs. The utilization of shear reinforcement via shear studs or other means has become a choice for improving the punching shear capacity. In this study, a new alternative of reinforcement modalities were tested and demonstrated the effect of self-compact concrete on the punching shear capacity, beside that compared between the difference codes to identify the suitable one for determining the position of critical section of punching shear. Nevertheless, in this investigation, the proposed reinforcement system is examined for interior columns only. An experimental work consisting of six specimens: five of them were cast with normal reinforced concrete and one was cast with self-compact strength concrete. The obtained results indicate that the proposed shear reinforcement system has a positive effect in the enhancement of the punching shear capacity of interior slab–column connection of self-compact strength concrete.


Sign in / Sign up

Export Citation Format

Share Document