Rehabilitation of reinforced concrete slab–column connections

2002 ◽  
Vol 29 (4) ◽  
pp. 602-611 ◽  
Author(s):  
Ehab F El-Salakawy ◽  
Maria Anna Polak ◽  
Khaled A Soudki

The paper presents work on punching shear rehabilitation and strengthening of existing slab–column connections. Four full-scale specimens representing slab–column edge connections were built and tested to failure. Three slabs were then repaired and strengthened and tested again. In the originally tested slabs, which were chosen for repair, one slab had an opening in front of the column and contained shear reinforcement, one slab had an opening and no shear reinforcement, and one had no opening and no reinforcement. The dimensions of the slabs were 1540 × 1020 × 120 mm with square columns (250 × 250 mm). The openings in the specimens were square (150 × 150 mm) with the sides parallel to the sides of the column. The slabs were made using normal weight concrete (28-day average compressive strength of 32 MPa) and reinforced with a reinforcement ratio of 0.75%. The slabs were repaired by replacing old-damaged concrete with new concrete of the same properties. Strengthening was carried out using shear studs for the two slabs, which originally did not have shear reinforcement. The rehabilitation increased the punching shear strength (by 26–41%) and the ductility of the connections. All repaired specimens failed in flexure.Key words: concrete slabs, punching shear, rehabilitation, edge connections, openings, studs, repair.

2011 ◽  
Vol 90-93 ◽  
pp. 933-939 ◽  
Author(s):  
Qiu Ning Yang ◽  
Ming Jie Mao ◽  
Sumio Hamada

Several equations for punching shear strength of the reinforced concrete slab have been proposed in the world. These equations have their own factors affecting the strength. There are numerous test data for punching shear strength of RC slabs, which have been obtained by numerous researchers. A database with approximately 300 specimens has been structured through the present study. In the present study seven equations for punching shear strength are evaluated based on the database. CCES equation is also evaluated from the present database.


2008 ◽  
Vol 400-402 ◽  
pp. 335-340
Author(s):  
Xiao Wei Wang ◽  
Wen Ling Tian ◽  
Zhi Yuan Huang ◽  
Ming Jie Zhou ◽  
Xiao Yan Zhao

The thickness of the raft slab is determined by punching shear. The raft slab is commonly thick, which causes concrete volume is large. Mass concrete can bring disadvantage to the foundation. In order to increase the bearing capacity and reduce the thickness, it is suggested that the raft slab to be reinforced by steel fibers. There are five groups of specimens in this paper. S1 is the common reinforced concrete slab. S2 and S3 are concrete slabs reinforced by steel fibers broadcasted layer by layer when casting specimen. S4 and S5 are concrete slabs reinforced by steel fibers mixed homogeneously when making concrete. The punching shear tests of these slabs were done. The test results indicate that the punching shear capacity of the slab reinforced with steel fibers is higher than that of concrete slab, the stiffness and crack resistance of the steel fibers reinforced concrete slab are better than those of the common concrete slab and the punching shear of the slabs with different construction methods of steel fibers is similar. It analyses the punching shear behavior of the slab reinforced with steel fibers and suggests the ultimate bearing formula. The calculative values are coincided with the measured values well.


Author(s):  
Dominic Joray ◽  
Martin Diggelmann

<p>The reinforced concrete slab of the reconstructed Station Square in Berne needed to be strengthened against punching shear. The case study led to the application of a newly developed post-installed punching shear reinforcement with inclined bonded bars.</p>


2019 ◽  
Vol 10 (1) ◽  
pp. 265 ◽  
Author(s):  
Cheng-Chih Chen ◽  
Shun-Long Chen

This study presents the structural behavior and punching shear strength of the concrete slab-column connections strengthened with carbon fiber reinforced polymer (CFRP) laminates. The variables considered for the twelve specimens included the compressive strength of the concrete, the ratio of the tensile steel reinforcement, and the amount of the CFRP laminates. Square concrete slabs were simply supported along four edges. During the test, monotonically concentrated load was applied to the stub column located at the center of the slab. The punching shear strength, stiffness, and mode of failure were investigated. Test results demonstrated that increasing the compressive strength of concrete, ratio of the steel reinforcement, and amount of the CFRP laminates led to an increase in the punching shear strength of the slabs. Moreover, the CFRP laminates were effective in appreciably increasing the punching shear strength of the slab-column connections. An analytical approach was conducted to calculate the punching shear strength of the slab-column connections strengthened with CFRP laminates. Based on the theory of reinforced concrete members, the application of the CFRP laminates increased the flexural strength of the slab and resulted in an increase of the effective depth of the slab section. Consequently, the punching shear strength was increased. The results of the analytical calculation revealed that the analytical work accurately predicted the experimental punching shear strength.


Author(s):  
Hamid Abdulmahdi Faris ◽  
Lubna Mohammed Abd

The "flat slab" is a reinforced concrete slab bolstered, by a number of columns. Punching, shear is a category for collapse for reinforced concrete slabs exposed to great confined forces. In "flat slab" constructions the shear failure happens, at column bolster joints. To avoid this, collapse two methods are used, first method is increasing the column dimensions and, the other is to use drop panel if the first method leads to uneconomical, design. Two examples are used to find the effect, of column dimensions, increase on the punching shear failure of "flat slab". The first example, is a "flat slab" of span (5 by 5) m and the other is of span (6 by 6) m. The column which examined is the interior, edge and corner columns, and the interior column is the most dangerous case. It is concluded that, the increase of column dimensions are lead to avoid of punching shear failure in "flat slab" and the drop panel is enlarge the area of the critical shear perimeter and this avoiding punching shear failure.


2018 ◽  
Vol 33 ◽  
pp. 02007 ◽  
Author(s):  
Valery Filatov

The article presents the methodology and results of an analytical study of structural parameters influence on the value of punching force for the joint of columns and flat reinforced concrete slab. This design solution is typical for monolithic reinforced concrete girderless frames, which have a wide application in the construction of high-rise buildings. As the results of earlier studies show the punching shear strength of slabs at rectangular columns can be lower than at square columns with a similar length of the control perimeter. The influence of two structural parameters on the punching strength of the plate is investigated - the ratio of the side of the column cross-section to the effective depth of slab C/d and the ratio of the sides of the rectangular column Cmax/Cmin. According to the results of the study, graphs of reduction the control perimeter depending on the structural parameters are presented for columns square and rectangular cross-sections. Comparison of results obtained by proposed approach and MC2010 simplified method are shown, that proposed approach gives a more conservative estimate of the influence of the structural parameters. A significant influence of the considered structural parameters on punching shear strength of reinforced concrete slabs is confirmed by the results of experimental studies. The results of the study confirm the necessity of taking into account the considered structural parameters when calculating the punching shear strength of flat reinforced concrete slabs and further development of code design methods.


2012 ◽  
Vol 450-451 ◽  
pp. 338-342
Author(s):  
Ming Jie Mao ◽  
Qiu Ning Yang

A lightweight aggregate with low permeability was employed in the concrete slab; and the strength of the slab is mainly discussed. The purpose of present study is to evaluate experimentally the punching shear strength of lightweight concrete slab, and to propose the punching shear strength equation for the slab with lightweight aggregate concrete. The applicability of the proposed equation to the both reinforced concrete and pre-stressed concrete slabs with lightweight aggregate concrete.


2014 ◽  
Vol 919-921 ◽  
pp. 1853-1859
Author(s):  
Ju Hong Han ◽  
Dun Bin Wang

Based on the mechanism of punching shear and patterns of failure of Specimen,using the unified strength theory and rigid-plastic models,the punching strength of reinforced concrete slabs supported on four sides is obtained.The theoretical formula of punching shear strength for concrete slab is given.The calculated results are in good agreement with the experimental results.


2002 ◽  
Vol 29 (1) ◽  
pp. 119-124
Author(s):  
Patrick Paultre ◽  
Caroline Moisan

Slabs with continuous drop panels between column lines facilitate formwork, make long spans possible in addition to increase punching shear resistance around supports and provide unobstructed spans with minimum structural floor depth resulting in lower floor-to-floor heights. The moment distribution in such slabs is different from that in conventional flat plates or slabs with drop panels systems. Dimensioning according to the current provisions in CSA A23.3-94 is problematic because the continuous drop panels are subject to moments exceeding the minimum values allowed by the Code for conventional slab systems. This analytical study presents the moment distribution in slabs with continuous drop panels in an attempt to provide more realistic transverse moment distribution factors.Key words: reinforced concrete, slab systems, slab design, drop panel, moment distribution.


Sign in / Sign up

Export Citation Format

Share Document