Seismic performance of a full-scale, reinforced high-performance concrete building. Part II: Analytical study

2008 ◽  
Vol 35 (8) ◽  
pp. 849-862 ◽  
Author(s):  
Sébastien Mousseau ◽  
Patrick Paultre ◽  
Jacky Mazars

Full-scale tests provide valuable information on the characteristics of building structures that can be used to evaluate design methods, to calibrate modelling techniques, and to determine damage corresponding to loading levels. These tests are scarce due to the enormous requirements in testing space and specialized testing equipment. The seismic behaviour of a full-scale, two-storey, reinforced high-performance concrete building designed with moderate ductility detailing is evaluated by pseudo-dynamic testing, during which increasing seismic loads are applied, resulting in increasing levels of permanent damage to the structure. This paper presents the analytical predictions of the test results using a global force–displacement parameters approach and a refined approach, half-way between global modelling and finite element modelling, using force–strain parameters and damage mechanics principles. Identification of the parameters required to describe the response parameters are presented together with a description of the numerical procedures used in each approach. It is shown that the predictions are in good agreement with the test results. Advantages and disadvantages of each approach are highlighted in the context of performance-based analysis and design.

2008 ◽  
Vol 35 (8) ◽  
pp. 832-848 ◽  
Author(s):  
Sébastien Mousseau ◽  
Patrick Paultre

Full-scale tests provide valuable information on the characteristics of building structures that can be used to evaluate design methods, to calibrate modelling techniques, and to determine damage corresponding to loading levels. These tests are scarce due to the enormous requirements in testing space and specialized testing equipment. The seismic behaviour of a full-scale, two-storey, reinforced high-performance concrete building designed with moderate ductility detailing is evaluated by pseudo-dynamic testing, during which increasing seismic loads are applied, resulting in increasing levels of permanent damage to the structure. To monitor the level of damage, a series of successive forced-vibration tests are also carried out at each step of the process and are used to track changes in the key dynamic properties of the building. The paper presents the design of the test structure according to the new edition of the CSA A23.3-04 Design of concrete structures standard, the series of pseudo-dynamic tests simulating different levels of earthquake excitation consistent with the 2005 edition of the National building code of Canada, and the evaluation of the performance of the building. It is shown that the detailing requirements of CSA A23.3-04 are more than adequate to provide the ductility and overstrength expected.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6964
Author(s):  
Mohamed Abokifa ◽  
Mohamed A. Moustafa

Full-depth precast bridge decks are widely used to expedite bridge construction and enhance durability. These deck systems face the challenge that their durability and performance are usually dictated by the effectiveness of their field joints and closure joint materials. Hence, commercial ultra-high performance concrete (UHPC) products have gained popularity for use in such joints because of their superior mechanical properties. However, the proprietary and relatively expensive nature of the robust UHPC mixes may pose some limitations on their future implementation. For these reasons, many research agencies along with state departments of transportation sought their way to develop cheaper non-proprietary UHPC (NP-UHPC) mixes using locally supplied materials. The objective of this study is to demonstrate the full-scale application of the recently developed NP-UHPC mixes at the ABC-UTC (accelerated bridge construction university transportation center) in transverse field joints of precast bridge decks. This study included experimental testing of three full-scale precast bridge deck subassemblies with transverse NP-UHPC field joints under static vertical loading. The test parameters included NP-UHPC mixes with different steel fibers amount, different joint splice details, and joint widths. The results of this study were compared with the results of a similar proprietary UHPC reference specimen. The structural behavior of the test specimens was evaluated in terms of the load versus deflection, reinforcement and concrete strains, and full assessment of the field joint performance. The study showed that the proposed NP-UHPC mixes and field joint details can be efficiently used in the transverse deck field joints with comparable behavior to the proprietary UHPC joints. The study concluded that the proposed systems remained elastic under the target design service and ultimate loads. In addition, the study showed that the use of reinforcement loop splices enhanced the load distribution across the specimen’s cross-section.


Author(s):  
Prasada Rao Rangaraju

In collaboration with FHWA, the Minnesota Department of Transportation (Mn/DOT) has successfully completed its first experimental high-performance concrete pavement (HPCP) project under the Testing and Evaluation Program (TE-30). This project is one of the 22 projects funded under the TE-30 Program. With a structural design life of 60 years, this HPCP is unique in that it incorporates significant changes to the existing Mn/DOT specifications on concrete materials. Some of the new materials-related specifications developed as a part of this project are based on performance criteria that influence long-term durability of the pavement structure. The background and considerations for selecting the new performance measures are discussed, and test results are presented that evaluate the practical feasibility of establishing and achieving the performance specifications.


Author(s):  
C. Xu ◽  
B. Y. Zhang ◽  
Z. H. Hou

<p>The application of high performance concrete has been increasingly concerned in the negative flexural region of steel‐concrete continuous composite girder because of its favorable tensile performance. However, the unclear cyclic and ultimate performance of a high performance concrete composite girder results to the problems which hinder the further application. In this case, a series of fatigue negative bending tests on HPC composite girders and fatigue push‐out tests on stud connectors in HPC were executed. The test results showed that the fatigue slip in the HPC composite girder was smaller than the normal concrete composite girder, and the fatigue life of stud in HPC was longer than the one in normal concrete. Meanwhile, according to the comparison between the stud fatigue live evaluations and test results, the AASHTO‐based evaluations were comparatively with larger safety redundancy, and JSCE was close to the test results but had smaller safety redundancy.</p>


2020 ◽  
Vol 10 (4) ◽  
pp. 1335 ◽  
Author(s):  
Shuwen Deng ◽  
Xudong Shao ◽  
Banfu Yan ◽  
Yan Wang ◽  
Huihui Li

Joints are always the focus of the precast structure for accelerated bridge construction. In this paper, a girder-to-girder joint suitable for steel-ultra-high-performance concrete (UHPC) lightweight composite bridge (LWCB) is proposed. Two flexural tests were conducted to verify the effectiveness of the proposed T-shaped girder-to-girder joint. The test results indicated that: (1) The T-shaped joint has a better cracking resistance than the traditional I-shaped joint; (2) The weak interfaces of the T-shaped joint are set in the areas with relatively lower negative bending moment, and thus the cracking risk could be decreased drastically; (3) The natural curing scheme for the joint is feasible, and the reinforcement has a very large inhibitory effect on the UHPC material shrinkage; The joint interface is the weak region of the LWCB, which requires careful consideration in future designs. Based on the experimental test results, the design and calculation methods for the deflection, crack width, and ultimate flexural capacity in the negative moment region of LWCB were presented.


2017 ◽  
Vol 8 (4) ◽  
pp. 392-401 ◽  
Author(s):  
Hassan A.M. Mhamoud ◽  
Jia Yanmin

Purpose This study aims to focus on the resistance to elevated temperatures of up to 700ºC of high-performance concrete (HPC) compared to ordinary Portland concrete (OPC) with regards to mass loss and residual compressive and flexural strength. Design/methodology/approach Two mixtures were developed to test. The first mixture, OPC, was used as the control, and the second mixture was HPC. After 28 days under water (per Chinese standard), the samples were tested for compressive strength and residual strength. Findings The test results showed that at elevated temperatures of up to 500ºC, each mixture experienced mass loss. Below this temperature, the strength and the mass loss did not differ greatly. Originality/value When adding a 10 per cent silica fume, 25 per cent fly, 25 per cent slag to HPC, the compressive strength increased by 17 per cent and enhanced the residual compressive strength. A sharp decrease was observed in the residual flexural strength of HPC when compared to OPC after exposure to temperatures of 700ºC.


2003 ◽  
Vol 30 (5) ◽  
pp. 841-849 ◽  
Author(s):  
Mostafa A Hassanain ◽  
Robert E Loov

Recent surveys have indicated that between 30% and 40% of all bridges in North America are in various states of deterioration. Funding is limited owing to the existence of other deficient components of the transportation infrastructure. It is clear, therefore, that the return on the available funding needs to be maximized. This paper presents a review of publications on cost optimization of concrete bridge components and systems and then continues with a review of the state-of-the-art in life-cycle cost (LCC) analysis and design of concrete bridges. The main objective of the paper is to encourage bridge engineers to move towards the increased use of advanced analysis and design optimization methods.Key words: bridge, concrete, cost, high-performance concrete, infrastructure, life-cycle cost, optimization, prestressed girders, reliability.