Oxygenation performance of a laboratory-scale Speece Cone hypolimnetic aerator: preliminary assessment

2008 ◽  
Vol 35 (7) ◽  
pp. 663-675 ◽  
Author(s):  
K. I. Ashley ◽  
D. S. Mavinic ◽  
K. J. Hall

A prototype laboratory-scale Speece Cone hypolimnetic aerator was used to examine the effect of oxygen input rate and outlet port water velocity on oxygen transfer, using four standard units of measure for quantifying oxygen transfer: (i) the oxygen transfer coefficient at 20 °C, KLa20 (h–1); (ii) the standard oxygen transfer rate (SOTR) (g O2·h–1); (iii) the standard aeration efficiency (SAE) (g O2 kW·h–1); and (iv) the standard oxygen transfer efficiency (SOTE) (%). The maximum inlet velocity (i.e., 70 cm·s–1) was only 23% of the recommended design velocity (i.e., 305 cm·s–1), and the two-phase bubble swarm did not properly develop inside the cone, but remained as a gas pocket at the top of the cone, resulting in a drastically reduced bubble surface area to water ratio. Therefore, all of the performance measures from this prototype Speece Cone were much lower than would be expected with the recommended design inlet velocity of 305 cm·s−1. Despite this difference, the system was still capable of oxygen transfer efficiencies of about 61%, under low gas flow rates, which is still higher than any full-lift design hypolimnetic aerator operating on air. Future research efforts are focused on building a pilot-scale Speece Cone, with as close to the correct inlet and outlet velocities, hydraulic residence time, and physical dimensions as possible, such that a two-phase bubble swarm could be generated. Once this experimental data is collected and analyzed, it can be properly compared with predictive models.

2009 ◽  
Vol 36 (1) ◽  
pp. 137-147 ◽  
Author(s):  
K.I. Ashley ◽  
D.S. Mavinic ◽  
K.J. Hall

A pilot-scale, full lift, hypolimnetic aerator was used to examine the effect of diffuser pore diameter, depth of diffuser submergence, and gas flow rate on oxygen transfer, using four standard units of measure for quantifying oxygen transfer: (a) KLa20 (h–1), the oxygen transfer coefficient at 20 °C; (b) SOTR (g O2·h–1), the standard oxygen transfer rate; (c) SAE (g O2·kWh–1), the standard aeration efficiency and (d) SOTE (%), the standard oxygen transfer efficiency. Diffuser depth (1.5 and 2.9 m) exerted a significant effect on KLa20, SOTR, SAE, and SOTE, with all units of measure increasing in response to increased diffuser depth. Both KLa20 and SOTR responded positively to increased gas flow rates (10, 20, 30, and 40 L·min–1), whereas both SAE and SOTE responded negatively. Orifice diameter (140, 400, and 800 µm) exerted a significant effect on KLa20, SOTR, SAE, and SOTE, with all units of measure increasing with decreasing orifice size. These experiments demonstrate how competing design factors interact to determine overall oxygen transfer rates in full lift hypolimnetic aeration systems. The practical application for full lift hypolimnetic aerator design is to maximize the surface area of the bubbles, use fine (i.e., ~140 μm) pore diameter diffusers, and locate the diffusers at the maximum practical depth.


Fluids ◽  
2021 ◽  
Vol 6 (6) ◽  
pp. 226
Author(s):  
Rashal Abed ◽  
Mohamed M. Hussein ◽  
Wael H. Ahmed ◽  
Sherif Abdou

Airlift pumps can be used in the aquaculture industry to provide aeration while concurrently moving water utilizing the dynamics of two-phase flow in the pump riser. The oxygen mass transfer that occurs from the injected compressed air to the water in the aquaculture systems can be experimentally investigated to determine the pump aeration capabilities. The objective of this study is to evaluate the effects of various airflow rates as well as the injection methods on the oxygen transfer rate within a dual injector airlift pump system. Experiments were conducted using an airlift pump connected to a vertical pump riser within a recirculating system. Both two-phase flow patterns and the void fraction measurements were used to evaluate the dissolved oxygen mass transfer mechanism through the airlift pump. A dissolved oxygen (DO) sensor was used to determine the DO levels within the airlift pumping system at different operating conditions required by the pump. Flow visualization imaging and particle image velocimetry (PIV) measurements were performed in order to better understand the effects of the two-phase flow patterns on the aeration performance. It was found that the radial injection method reached the saturation point faster at lower airflow rates, whereas the axial method performed better as the airflow rates were increased. The standard oxygen transfer rate (SOTR) and standard aeration efficiency (SAE) were calculated and were found to strongly depend on the injection method as well as the two-phase flow patterns in the pump riser.


2012 ◽  
Vol 65 (7) ◽  
pp. 1172-1178 ◽  
Author(s):  
U. Barry ◽  
J.-M. Choubert ◽  
J.-P. Canler ◽  
A. Héduit ◽  
L. Robin ◽  
...  

This work suggests a procedure to correctly calibrate the parameters of a one-dimensional MBBR dynamic model in nitrification treatment. The study deals with the MBBR configuration with two reactors in series, one for carbon treatment and the other for nitrogen treatment. Because of the influence of the first reactor on the second one, the approach needs a specific calibration strategy. Firstly, a comparison between measured values and simulated ones obtained with default parameters has been carried out. Simulated values of filtered COD, NH4-N and dissolved oxygen are underestimated and nitrates are overestimated compared with observed data. Thus, nitrifying rate and oxygen transfer into the biofilm are overvalued. Secondly, a sensitivity analysis was carried out for parameters and for COD fractionation. It revealed three classes of sensitive parameters: physical, diffusional and kinetic. Then a calibration protocol of the MBBR dynamic model was proposed. It was successfully tested on data recorded at a pilot-scale plant and a calibrated set of values was obtained for four parameters: the maximum biofilm thickness, the detachment rate, the maximum autotrophic growth rate and the oxygen transfer rate.


2013 ◽  
Vol 67 (12) ◽  
pp. 2692-2698 ◽  
Author(s):  
P. Wójtowicz ◽  
M. Szlachta

Hydrodynamic flow regulators are used in environmental engineering as a replacement for traditional flow throttling devices. They are extremely efficient, reliable and free from the common disadvantages of traditional devices. Recent research by the authors indicated that the atomization of a liquid by hydrodynamic flow regulators accelerates oxygenation and may be used for improving the quality of wastewater and stormwater. To date, an evaluation of the aeration capacity of a hydrodynamic flow regulator at the pilot scale or in a practical situation has not been presented in the literature. This study presents the experimental results of oxygen absorption tests for conventional and modified cylindrical hydrodynamic flow regulators (patent pending). These devices were tested in a closed-circuit experimental setup at the semi-commercial scale. The aeration efficiency of hydrodynamic flow regulators was assessed by means of the overall standard oxygen transfer coefficient (KLa(20), h−1) and standard oxygen transfer rate (SOTR, gO2/h) for a wide range of tested configurations. The effect of flow rate and discharge mode on the aeration capacity of flow regulators was investigated. The values of KLa(20) for cylindrical hydrodynamic flow regulators obtained in the experiments were between 2.62 and 15.57 h−1 while SOTR values ranged from 53 to 316 gO2/h. The modified discharge mode with two active outlets allowed for an increase in aeration efficiency of up to 15% compared to conventional designs.


2001 ◽  
Vol 22 (9) ◽  
pp. 1055-1068
Author(s):  
J. Kang ◽  
C.-H. Lee ◽  
S. Haam ◽  
K. K. Koo ◽  
W.-S. Kim

2008 ◽  
Vol 7 (3) ◽  
pp. 199-211 ◽  
Author(s):  
Dan Cascaval ◽  
Anca-Irina Galaction ◽  
Stefanica Camarut ◽  
Radu Z. Tudose

1996 ◽  
Vol 34 (3-4) ◽  
pp. 413-420
Author(s):  
Y. C. Liao ◽  
D. J. Lee

Transient model of oxygen transfer rate in a sequencing batch reactor is derived and solved numerically. The dissolved oxygen response under several conditions is analyzed. Effects of operational parameters and liquid bath height are studied. When with short, intermittent aeration periods, the transient effects on oxygen transfer rate may be substantial and should be taken into considerations. An example considering bioreaction is also given.


1998 ◽  
Vol 38 (8-9) ◽  
pp. 179-188 ◽  
Author(s):  
K. F. Janning ◽  
X. Le Tallec ◽  
P. Harremoës

Hydrolysis and degradation of particulate organic matter has been isolated and investigated in laboratory scale and pilot scale biofilters. Wastewater was supplied to biofilm reactors in order to accumulate particulates from wastewater in the filter. When synthetic wastewater with no organic matter was supplied to the reactors, hydrolysis of the particulates was the only process occurring. Results from the laboratory scale experiments under aerobic conditions with pre-settled wastewater show that the initial removal rate is high: rV, O2 = 2.1 kg O2/(m3 d) though fast declining towards a much slower rate. A mass balance of carbon (TOC/TIC) shows that only 10% of the accumulated TOC was transformed to TIC during the 12 hour long experiment. The pilot scale hydrolysis experiment was performed in a new type of biofilm reactor - the B2A® biofilter that is characterised by a series of decreasing sized granular media (80-2.5 mm). When hydrolysis experiments were performed on the anoxic pilot biofilter with pre-screened wastewater particulates as carbon source, a rapid (rV, NO3=0.7 kg NO3-N/(m3 d)) and a slowler (rV, NO3 = 0.3 kg NO3-N/(m3 d)) removal rate were observed at an oxygen concentration of 3.5 mg O2/l. It was found that the pilot biofilter could retain significant amounts of particulate organic matter, reducing the porosity of the filter media of an average from 0.35 to 0.11. A mass balance of carbon shows that up to 40% of the total incoming TOC accumulates in the filter at high flow rates. Only up to 15% of the accumulated TOC was transformed to TIC during the 24 hour long experiment.


2003 ◽  
Vol 3 ◽  
pp. 266-270
Author(s):  
B.H. Khudjuyerov ◽  
I.A. Chuliev

The problem of the stability of a two-phase flow is considered. The solution of the stability equations is performed by the spectral method using polynomials of Chebyshev. A decrease in the stability region gas flow with the addition of particles of the solid phase. The analysis influence on the stability characteristic of Stokes and Archimedes forces.


Sign in / Sign up

Export Citation Format

Share Document