Analytical methods for determination of aerosols by means of membrane ultrafilters. X. Comparison of methods used for the determination of the mean radius and the pore distribution curve

1967 ◽  
Vol 32 (12) ◽  
pp. 4181-4189 ◽  
Author(s):  
V. Hampl ◽  
K. Spurný
2015 ◽  
Vol 8 (4) ◽  
pp. 405-413 ◽  
Author(s):  
S. Mohd Redzwan ◽  
R. Jamaluddin ◽  
A.M. Mohd Sokhini ◽  
A.R. Nurul Aqilah ◽  
A. Zuraini ◽  
...  

The development of analytical methods to detect aflatoxin B1 (AFB1) in foodstuffs and its metabolites in human biological samples is useful for risk assessment. The latter methodology, i.e. the measurement of AFB1 biomarkers, has become important to assess human aflatoxin exposure. AFB1-lysine adduct, AFB1-DNA adduct and urinary aflatoxin M1 (AFM1) are some of the AFB1 biomarkers that can be measured by several analytical methods, such as enzyme-linked immunosorbent assay, radioimmunoassay, and high performance liquid chromatography (HPLC). HPLC coupled to a fluorescence detector is useful and preferable due to its high degree of sensitivity, but the analysis may take time and consume large amount of solvents. Therefore, the present study extrapolated the HPLC method to ultra-HPLC for the determination of urinary AFM1. After the extraction procedure with an immunoaffinity column, chromatographic separation was done using a high performance 1.8 μm microparticulate C18 column. The mean recovery from urine samples spiked with 0.5, 1.0 and 2.0 ng/ml AFM1 was 84.4±4.0%, with acceptable recovery values, interday (6.0±5.3%) and intraday (2.6±0.6%) coefficients of variation. The retention time was 5.7 min. This method was used to measure urinary AFM1 in 71 subjects, of which 13 had AFM1 levels above the limit of detection (0.018 ng/ml). The mean urinary AFM1 level of the positive samples was 18.8±28.6 pg/ml, ranging from 2.4 to 100.4 pg/ml. As this is one of the few studies investigating the occurrence of aflatoxin biomarkers in human biological samples in Malaysia, a study with a larger sample size is necessary to investigate the magnitude of aflatoxin exposure among the population.


1996 ◽  
Vol 75 (05) ◽  
pp. 772-777 ◽  
Author(s):  
Sybille Albrecht ◽  
Matthias Kotzsch ◽  
Gabriele Siegert ◽  
Thomas Luther ◽  
Heinz Großmann ◽  
...  

SummaryThe plasma tissue factor (TF) concentration was correlated to factor VII concentration (FVIIag) and factor VII activity (FVIIc) in 498 healthy volunteers ranging in age from 17 to 64 years. Immunoassays using monoclonal antibodies (mAbs) were developed for the determination of TF and FVIIag in plasma. The mAbs and the test systems were characterized. The mean value of the TF concentration was 172 ± 135 pg/ml. TF showed no age- and gender-related differences. For the total population, FVIIc, determined by a clotting test, was 110 ± 15% and the factor VIlag was 0.77 ± 0.19 μg/ml. FVII activity was significantly increased with age, whereas the concentration demonstrated no correlation to age in this population. FVII concentration is highly correlated with the activity as measured by clotting assay using rabbit thromboplastin. The ratio between FVIIc and FVIIag was not age-dependent, but demonstrated a significant difference between men and women. Between TF and FVII we could not detect a correlation.


1966 ◽  
Vol 16 (01/02) ◽  
pp. 038-050 ◽  
Author(s):  
Ulla Hedner ◽  
Inga Marie Nilsson ◽  
B Robertson

SummaryThe plasminogen content was determined by a casein method in plasma and serum from 20 normal volunteers. The mean plasminogen content was found to be 10.1 ACU (the arbitrary caseinolytic unit defined in such a way that using a 3% casein solution and a digestion time of 20 min. at 37°C, 10 ACU gave an extinction of 0.300). No difference between serum and plasma regarding the plasminogen content was found.Plasminogen was determined in drained and drained plus washed clots prepared from 2 ml plasma. The highest values found in the drained clots were 0.9 ACU/clot and 0.2 ACU/clot in the drained plus washed clots.Plasminogen was also determined in drained and drained plus washed clots prepared from plasma with added purified plasminogen. The plasminogen was recovered in the washing fluid. According to these tests, then, purified added plasminogen is washed out of the clots.The plasminogen content of 20 thrombi obtained post mortem was also determined. The mean value was found to be 0.7 ACU/cm thrombus. Judging from our results, the “intrinsic clot lysis theory” is not the main mechanism of clot dissolution.


1973 ◽  
Vol 72 (4) ◽  
pp. 714-726 ◽  
Author(s):  
A. Burger ◽  
B. Miller ◽  
C. Sakoloff ◽  
M. B. Vallotton

ABSTRACT An improved method for the determination of serum triiodothyronine (T3) has been developed. After addition of a tracer amount of the hormone, T3 was extracted from 1 ml serum under conditions of pH and ionic strength which favoured T3 extraction (89%) over thyroxine (T4) extraction (58%). Chromatography of the extracted material on Sephadex LH-20 separated T3 completely from residual T4. The T3 eluate was dried, then re-dissolved in 0.5 ml NaOH 0.04 n. To 0.2 ml duplicate aliquots, a standard amount of TBG was added for the competitive protein analysis. After one hour incubation at 4°C, separation of bound from free T3 was achieved on small Sephadex G-25 columns. Overall recovery was 67 ± 10.8% and correction for the loss was made. The solvent blank was 37 ± 27 (sd) ng/100 ml. Accuracy of measurement of known quantities of T3 added to serum was 98.4%. The coefficient of variation within the assay was 6.2% and between the assays it was 11.4%. The limit of detection (0.1 ng) corresponded to a concentration of 25 ng/100 ml. T4 added to serum did not interfere with T3 determination until high non-physiological values were reached. The mean ± sd serum T3 in 54 euthyroid subjects was 153 ± 58 ng/100 ml and in 24 hyperthyroid patients it was 428 ±186 ng/100 ml; 4 out of the 24 hyperthyroid values were within 2 sd of the mean euthyroid group. All the values found in the euthyroid group were well above the limit of detection of the method.


2012 ◽  
Vol 2 (8) ◽  
pp. 66-68
Author(s):  
Shreya Nayak ◽  
◽  
Sanjay Pai P.N. Sanjay Pai P.N.
Keyword(s):  

2010 ◽  
Vol 35 (4) ◽  
pp. 543-550 ◽  
Author(s):  
Wojciech Batko ◽  
Bartosz Przysucha

AbstractAssessment of several noise indicators are determined by the logarithmic mean <img src="/fulltext-image.asp?format=htmlnonpaginated&src=P42524002G141TV8_html\05_paper.gif" alt=""/>, from the sum of independent random resultsL1;L2; : : : ;Lnof the sound level, being under testing. The estimation of uncertainty of such averaging requires knowledge of probability distribution of the function form of their calculations. The developed solution, leading to the recurrent determination of the probability distribution function for the estimation of the mean value of noise levels and its variance, is shown in this paper.


Sign in / Sign up

Export Citation Format

Share Document