Physiological studies of binaural tone-in-noise detection in the inferior colliculus of awake rabbit

2019 ◽  
Vol 145 (3) ◽  
pp. 1719-1720
Author(s):  
Langchen Fan ◽  
Kenneth S. Henry ◽  
Laurel H. Carney
1998 ◽  
Vol 80 (3) ◽  
pp. 1302-1316 ◽  
Author(s):  
Ruth Y. Litovsky ◽  
Tom C. T. Yin

Litovsky, Ruth Y. and Tom C. T. Yin. Physiological studies of the precedence effect in the inferior colliculus of the cat. II. Neural mechanisms. J. Neurophysiol. 80: 1302–1316, 1998. We studied the responses of neurons in the inferior colliculus (IC) of cats to stimuli known to evoke the precedence effect (PE). This paper focuses on stimulus conditions that probe the neural mechanisms underlying the PE but that are not usually encountered in a natural situation. Experiments were conducted under both free-field (anechoic chamber) and dichotic (headphones) conditions. We found that in free field the amount of suppression of the lagging response depended on the location of the leading source. With stimuli in the azimuthal plane, the majority (84%) of units showed stronger suppression of the lagging response for a leading stimulus placed in the cell's responsive area as compared with a lead in the unresponsive field. A smaller number of units showed stronger suppression for a lead placed in the unresponsive field, and a few showed little effect of the lead location. In the elevational plane, there was less sensitivity of the leading source to changes in location, but for those cells in which there was sensitivity, suppression was always stronger when the lead was in the cell's responsive area. Studies on stimulus locations also were conducted under dichotic conditions by varying the interaural differences in time (ITD) of the leading source. Results were consistent with those obtained in free field, suggesting that ITDs play an important role in determining the amount of suppression that was observed as a function of leading stimulus location. In addition to location and ITD, we also studied the effect of varying the relative levels of the lead and lag as well as stimulus duration. For all units studied, increasing the level of the leading stimulus while holding the lagging stimulus constant resulted in increased suppression. Similar effects of leading source level were observed in azimuth and elevation. The effect of varying the duration of the leading source also showed that longer duration stimuli produce stronger suppression; this finding was observed both in azimuth and elevation. We also compared the suppression observed under binaural and monaural contralateral conditions and found a mixed effect: some neurons show stronger suppression under binaural conditions, others to monaural contralateral conditions, and still others show no effect. The results presented here support the hypothesis that the PE reflects a long-lasting inhibition evoked by the leading stimulus. Five possible sources for the inhibition are considered: the auditory nerve, intrinsic circuits in the cochlear nucleus, medial and lateral nuclei of the trapezoid body inhibition to the medial superior olive, dorsal nucleus of the lateral lemniscus (DNLL) inhibition to the ICC, and intrinsic circuits in the ICC itself.


1998 ◽  
Vol 80 (3) ◽  
pp. 1285-1301 ◽  
Author(s):  
Ruth Y. Litovsky ◽  
Tom C. T. Yin

Litovsky, Ruth Y. and Tom C. T. Yin. Physiological studies of the precedence effect in the inferior colliculus of the cat. I. Correlates of psychophysics. J. Neurophysiol. 80: 1285–1301, 1998. The precedence effect (PE) is experienced when two spatially separated sounds are presented with such a brief delay that only a single auditory image at or toward the location of the leading source is perceived. The responses of neurons in the central nucleus of the inferior colliculus (ICC) of cats were studied using stimuli that are known to elicit the PE, focusing on the effects of changes in stimulus conditions that a listener might encounter in a natural situation. Experiments were conducted under both free-field (anechoic chamber) and dichotic (headphones) conditions. In free field, the PE was simulated by presenting two sounds from different loudspeakers with one sound delayed relative to the other. Either click or noise stimuli (2- to 10-ms duration) were used. Dichotically, the same conditions were simulated by presenting two click or noise pairs separated by an interstimulus delay (ISD) with interaural time differences (ITDs) imposed separately for each pair. At long ISDs, all neurons responded to both leading and lagging sources as if they were delivered alone. As the ISDs were shortened, the lagging response became suppressed. The ISD of half-maximal suppression varied considerably within the population of neurons studied, ranging from 2 to 100 ms, with means of 35 and 38 ms for free field and dichotic conditions, respectively. Several correlates of psychophysical findings were observed in ICC neurons: suppression was usually stronger with lower overall stimulus level and longer duration stimuli. Suppression also was compared along the azimuth and elevation in free field by placing the lagging source at (0°,0°), which is common to both axes, and the leading sources at locations along either plane that generated similar discharge rates. All neurons that showed suppression along the azimuth also did so in the elevation. In addition, there was a high correlation in the ISD of half-maximal suppression along the two planes ( r = 0.87). These findings suggest that interaural difference cues, which are robust along the horizontal axis but minimal in the median plane, are not necessary for neural correlates of the PE to be manifested. Finally, single-neuron responses did not demonstrate a correlate of build-up of suppression, a phenomenon whereby echo suppression accumulates with ongoing stimulation. This finding adds credibility to theories about the PE that argue for a “higher order” component of the PE.


2020 ◽  
Author(s):  
Charles A. Williams ◽  
Kimberly E. Miller ◽  
Nisa P. Williams ◽  
Christine V. Portfors ◽  
David J. Perkel