Low-cost interferometric TDM technology for dynamic sensing applications

2004 ◽  
Author(s):  
Jeff Bush ◽  
Allen Cekorich
2020 ◽  
Vol 90 (3) ◽  
pp. 30502
Author(s):  
Alessandro Fantoni ◽  
João Costa ◽  
Paulo Lourenço ◽  
Manuela Vieira

Amorphous silicon PECVD photonic integrated devices are promising candidates for low cost sensing applications. This manuscript reports a simulation analysis about the impact on the overall efficiency caused by the lithography imperfections in the deposition process. The tolerance to the fabrication defects of a photonic sensor based on surface plasmonic resonance is analysed. The simulations are performed with FDTD and BPM algorithms. The device is a plasmonic interferometer composed by an a-Si:H waveguide covered by a thin gold layer. The sensing analysis is performed by equally splitting the input light into two arms, allowing the sensor to be calibrated by its reference arm. Two different 1 × 2 power splitter configurations are presented: a directional coupler and a multimode interference splitter. The waveguide sidewall roughness is considered as the major negative effect caused by deposition imperfections. The simulation results show that plasmonic effects can be excited in the interferometric waveguide structure, allowing a sensing device with enough sensitivity to support the functioning of a bio sensor for high throughput screening. In addition, the good tolerance to the waveguide wall roughness, points out the PECVD deposition technique as reliable method for the overall sensor system to be produced in a low-cost system. The large area deposition of photonics structures, allowed by the PECVD method, can be explored to design a multiplexed system for analysis of multiple biomarkers to further increase the tolerance to fabrication defects.


Chemosensors ◽  
2021 ◽  
Vol 9 (5) ◽  
pp. 108
Author(s):  
Giancarla Alberti ◽  
Camilla Zanoni ◽  
Vittorio Losi ◽  
Lisa Rita Magnaghi ◽  
Raffaela Biesuz

This review illustrates various types of polymer and nanocomposite polymeric based sensors used in a wide variety of devices. Moreover, it provides an overview of the trends and challenges in sensor research. As fundamental components of new devices, polymers play an important role in sensing applications. Indeed, polymers offer many advantages for sensor technologies: their manufacturing methods are pretty simple, they are relatively low-cost materials, and they can be functionalized and placed on different substrates. Polymers can participate in sensing mechanisms or act as supports for the sensing units. Another good quality of polymer-based materials is that their chemical structure can be modified to enhance their reactivity, biocompatibility, resistance to degradation, and flexibility.


2020 ◽  
Author(s):  
M Abdul Kaiyum ◽  
Naim Ahmed ◽  
Arif Alam ◽  
M Shamimur Rahman

Abstract Yttrium (Y) doped and pure Titanium Di-oxide (TiO2) thin films were prepared by using spin coater. The coater was set up in laboratory with low cost investment. The films were calcined at 450 °C for 1 hour. For characterization, Scanning Electron Microscopy (SEM), Energy Dispersive X-Ray Analysis (EDX), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Atomic Force Microscopy (AFM) were carried out. LCR Bridge - GW Instek LCR-821 was used for gas sensing applications. XPS showed that the change of electronic structure due to Y doping. SEM and AFM analysis were carried out to determine the surface morphology of the films. Yttrium (Y) decreased the crystallite size of the films and increased the surface roughness and porosity value, which was very good for many sensing applications. Gas sensing property of the deposited films were improved by the incorporation of yttrium impurities and the sensing property improved almost two times than pure TiO2 thin film. Different researches have been done their research related to this topic but no one researchers provide a precise explanation of their results, authors of this research have tried to do that. Moreover the films were prepared by a simple spin coater to reduce the production cost also.


2018 ◽  
Vol 24 (4) ◽  
pp. 739-743 ◽  
Author(s):  
Simone Luigi Marasso ◽  
Matteo Cocuzza ◽  
Valentina Bertana ◽  
Francesco Perrucci ◽  
Alessio Tommasi ◽  
...  

Purpose This paper aims to present a study on a commercial conductive polylactic acid (PLA) filament and its potential application in a three-dimensional (3D) printed smart cap embedding a resistive temperature sensor made of this material. The final aim of this study is to add a fundamental block to the electrical characterization of printed conductive polymers, which are promising to mimic the electrical performance of metals and semiconductors. The studied PLA filament demonstrates not only to be suitable for a simple 3D printed concept but also to show peculiar characteristics that can be exploited to fabricate freeform low-cost temperature sensors. Design/methodology/approach The first part is focused on the conductive properties of the PLA filament and its temperature dependency. After obtaining a resistance temperature characteristic of this material, the same was used to fabricate a part of a 3D printed smart cap. Findings An approach to the characterization of the 3D printed conductive polymer has been presented. The major results are related to the definition of resistance vs temperature characteristic of the material. This model was then exploited to design a temperature sensor embedded in a 3D printed smart cap. Practical implications This study demonstrates that commercial conductive PLA filaments can be suitable materials for 3D printed low-cost temperature sensors or constitutive parts of a 3D printed smart object. Originality/value The paper clearly demonstrates that a new generation of 3D printed smart objects can already be obtained using low-cost commercial materials.


Author(s):  
Qiqi Sun ◽  
Qi Liu ◽  
Wen Gao ◽  
Chuanwang Xing ◽  
Jingshun Shen ◽  
...  

The cathodic photoelectrochemical (PEC) biosensor, is one of ideal systems for sensing applications owing to its advantages in the low-cost, simplicity of the detection and miniaturization of the sensors with...


2016 ◽  
Vol 2016 (1) ◽  
pp. 000557-000562
Author(s):  
Robert N. Dean ◽  
Frank T. Werner ◽  
Michael J. Bozack

Abstract Printed circuit board (PCB) sensors using low-cost commercial printed circuit board fabrication processes have been demonstrated for environmental sensing applications. One configuration of these sensors uses exposed electrodes to measure saltwater concentration in freshwater/seawater mixtures, through monitoring the resistance between the electrodes when they are immersed in the saltwater/freshwater solution. The lowest cost commercial PCB processes use an immersion Sn HASL surface finish on exposed copper cladding, including the sensing electrodes. This commercial PCB process has been demonstrated to make an effective, low-cost, short-lifetime sensor for saltwater concentration testing. The Sn finish, however, may not be optimal for this application. Sn oxidizes, which can interfere with sensor performance. Additionally, Sn and Sn oxides are potentially reactive with chemical constituents in seawater and seawater/freshwater solutions. An immersion Au (ENIG) surface finish is certainly less reactive with the atmosphere and chemicals likely present in the testing environment. However, an immersion Au finish increases the cost of the sensors by 30% to 40%. To investigate if the possible benefits of the more expensive Au surface finish are worth the extra expense, a study was performed where identical PCB sensors were procured from a commercial vendor with their standard low-cost Sn HASL finish and with their standard ENIG surface finish. Both sets of sensors were then evaluated in concentrations of seawater and freshwater, from 0% to 100% seawater concentration, using freshwater samples from a natural freshwater source near the coast where the seawater was obtained. Testing demonstrated an insignificant difference in sensor performance between the Sn HASL and the ENIG coated sensing electrodes. The results of this investigation indicated that for applications where the sensors will not be used for long periods of time, the added expense of an immersion Au surface finish is not worth the added cost.


Sensors ◽  
2020 ◽  
Vol 20 (19) ◽  
pp. 5486
Author(s):  
Junning Ma ◽  
Dorin Harpaz ◽  
Yang Liu ◽  
Evgeni Eltzov

Bioluminescent bacteria whole-cell biosensors (WCBs) have been widely used in a range of sensing applications in environmental monitoring and medical diagnostics. However, most of them use planktonic bacteria cells that require complicated signal measurement processes and therefore limit the portability of the biosensor device. In this study, a simple and low-cost immobilization method was examined. The bioluminescent bioreporter bacteria was absorbed on a filter membrane disk. Further optimization of the immobilization process was conducted by comparing different surface materials (polyester and parafilm) or by adding glucose and ampicillin. The filter membrane disks with immobilized bacteria cells were stored at −20 °C for three weeks without a compromise in the stability of its biosensing functionality for water toxicants monitoring. Also, the bacterial immobilized disks were integrated with smartphones-based signal detection. Then, they were exposed to water samples with ethanol, chloroform, and H2O2, as common toxicants. The sensitivity of the smartphone-based WCB for the detection of ethanol, chloroform, and H2O2 was 1% (v/v), 0.02% (v/v), and 0.0006% (v/v), respectively. To conclude, this bacterial immobilization approach demonstrated higher sensitivity, portability, and improved storability than the planktonic counterpart. The developed smartphone-based WCB establishes a model for future applications in the detection of environmental water toxicants.


Proceedings ◽  
2018 ◽  
Vol 2 (13) ◽  
pp. 1080
Author(s):  
Vladislav Komenko ◽  
Andrey Kravchenko ◽  
Wolf-Joachim Fischer

Within the current work, we present a miniaturized IR-Emitter based on Silicon-On-Nothing (SON) technology capable of producing 10 ms pulses. Transition to monocrystalline silicon, as the material choice for the filament, is governed by improved reliability and greater thermal stability as opposed to polycrystalline silicon alternative, commonly used in such class of devices. Compact design, low-cost processing and exceptional filament material properties make the presented device a favorite solution for integrated gas sensing applications. Numerical modeling and measurements of the IR-Emitter are performed to investigate the heating dynamics and assess the structure’s behavior at extreme temperatures as well as confirm the target performance. Additionally, a part of the work is dedicated to cover the insight of used fabrication process and the discussion of further improvements.


2018 ◽  
Author(s):  
Pedro Veras Guimarães ◽  
Fabrice Ardhuin ◽  
Peter Sutherland ◽  
Mickael Accensi ◽  
Michel Hamon ◽  
...  

Abstract. Global Navigation Satellite Systems (GNSS) and modern motion-sensor packages allow the measurement of ocean surface waves with low-cost drifters. Drifting along or across current gradients provides unique measurements of wave-current interactions. In this study, we investigate the response of several combinations of GNSS receiver, motion-sensor package and hull design in order to define a prototype surface kinematic buoy (SKIB) that is particularly optimized for measuring wave-current interactions, including relatively short wave components (relative frequency around 1 Hz) that are important for air-sea interactions and remote sensing applications. The comparison with existing Datawell Directional Waverider and SWIFT buoys, as well as stereo-video imagery demonstrates the accuracy of SKIB. The use of low-cost accelerometers and a spherical ribbed and skirted hull design provide acceptable heave spectra, while velocity estimates from GNSS receivers yield a mean direction and directional spread. Using a low-power acquisition board allows autonomous deployments over several months with data transmitted by satellite. The capability to measure current-induced wave variations is illustrated with data acquired in a macro-tidal coastal environment.


Sign in / Sign up

Export Citation Format

Share Document